MAURY USCG vessel records Sign in
← All vessels

OAKTREE

OAKTREE is a 2008 tank ship. The Coast Guard has recorded 41 inspections since 2008, most recently in May 2026, along with 7 deficiencies and 7 operational controls.

Records from 2008 to 2026. Most recent: inspection, 16 May 2026.

Built
2008
Last inspected
16 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9384021 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
945516
Flag
LIBERIA
—
Maury page id
psix-945516

Inspections, by type

…with no type recorded12
Years with a record 14 calendar years (2008–2026)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13579 - Convention (Subpart B), Net Ton
61314 - Displacement, Metric Ton
49999 - Dead Weight, Metric Ton
30109 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 41

16 May 2026 COC-CHEM & TVE Annual · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8370483
15 May 2026 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8374124
12 May 2026 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8396179
15 December 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8044674
20 December 2023 COC-CHEM & TVE Annual
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7840352
9 December 2022 PSC C · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7606707
30 April 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7441244
9 December 2021 PSC B · Administrative Inspection · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7363130
2 December 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7361171
28 November 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7358157
4 December 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7102717
31 July 2018 Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6495522
24 July 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6489448
11 November 2017 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6304985
7 July 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6201268
2 June 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6163163
29 April 2017 ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6134972
20 February 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6091688
15 December 2016 Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6057902
4 November 2016 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6035604
26 October 2016 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6030023
26 September 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6009569
17 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5879184
17 May 2016 Ballast Water Examination · ISPS III Exam · NPV Safety Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5879230
5 May 2016 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5869474
5 September 2015 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5235682
5 September 2015 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5238296
1 September 2015 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5231942
25 July 2012 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4390198
24 July 2012 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4390607
6 June 2012 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4334365
20 February 2010 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3682869
19 December 2009 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3653184
30 July 2009 NPV Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3551756
8 July 2009 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3528246
6 April 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3445877
6 April 2009 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3447166
17 September 2008 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3326865
13 August 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3297587
3 July 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3255810
25 April 2008 ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3191898

Deficiency record · 7

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 July 2018 Resolved
TO DISCHARGE BALLAST WATER INTO THE WATERS OF THE UNITED STATES...MUST EITHER ENSURE THAT THE BALLAST WATER MEETS THE BW DISCHARGE STANARD IN 151.2030(a), USE AMS AS DESCRIBED IN 151.2050(a)(3), OR BALLAST WITH WATER FROM A U.S. PUBLIC WATER SYSTEM. THE VESSEL IS PAST ITS COMPLIANCE DATE PER SCHEDULE IN 33 CFR 151.2035(b). CURRENT METHOD OF BALLAST WATER MANAGEMENT IS EXHANGE AND DISCHARGE (NOT AUTHORIZED) AND HAS NO BALLAST WATER TREATMENT SYSTEM INSTALLED. DEFICIENCY WILL NOT BE CLEARED UNTIL CG EXAMINERS RECEIVE DOCUMENTATION THAT THE VESSEL HAS INSTALLED A BWTS, HAS DECIDED TO USE U.S. PUBLIC WATER SYSTEM, OR HAS UPDATED ITS BALLAST WATER MANAGEMENT PLAN TO STATE THE VESSELS METHOD IN U.S. WATERS IS TO NEVER DISCHARGE UNTIL TREATMENT SYSTEM IS INSTALLED... 33 CFR 151.2035
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 3 August 2018
Resolution: Received proper documentation satisfying the requirement and cleared deficiency.
Engineering › Reduction Gearing/Clutches › Gear
Issued 4 November 2016 Resolved
1410-Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. While underway vessels reverse solenoid valve was found to be inoperative. Vessel must prove proper operation of astern propulsion. 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2016
Fire Fighting › Automatic Sprinkler System › Power Sources
Issued 26 September 2016 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The vessel reported a defective PCB rendered the Engine Room Water Mist System inoperable. Provide Class attestation to the proper repair and operation of the Engine Room Water Mist System.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2016
Resolved 27 September 2016
Resolution: Water mist system has been repaired and is now operable.
Engineering › Diesel Engine (propulsion-direct drive) › Nozzle, Injection (fuel injection)
Issued 17 May 2016 Resolved
1410 - Propulsion - The condition of the ship and its equipment shall be maintained to conform with the provisions. Vessel experienced a loss of power on the main engine. See narrative for details. SOLAS I/11 10c
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 May 2016
Resolved 19 May 2016
Resolution: PSCO reviewed class report and master's statement, which was found satisfactory to the attending examiner. See narrative for details.
Engineering › Diesel Engine (propulsion-direct drive) › Piston
Issued 25 July 2012 Resolved
1410 - THE ABILITY OF THE MACHINERY TO REVERSE THE DIRECTION OF THRUST OF THE PROPELLER IN SUFFICIENT TIME SHALL BE DEMONSTRATED AND RECORDED. MAIN ENGINE FAILED TO MEET AN ASTERN BELL DURING PRE-ARRIVAL TESTS. 74 SOLAS (04 CONS) II-1/28.2; 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 July 2012
Resolution: Received class survey report stating that 4 tests of astern propulsion were done and tests were satisfactory .
Navigation › Collision/Grounding Avoidance › Radar
Issued 19 December 2009 Resolved
LOD submitted for INOP Secondary Radar. Restricted to Daylight transit only with tug assist as determined by Corpus Christi Pilots.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2009
Resolution: Recieved technician''s report attesting to the proper operation of the Secondary Radar. Vessel''s restriction has been lifted.
Engineering › Steering Gear System › Power Unit
Issued 30 July 2009 Resolved
The #2 steering pump is inoperative. Make permanent repairs to the satisfaction of the SOLAS Cargo Ship Safety Construction Certificate issuing authority (DNV) prior to next U. S. port.
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 3 August 2009
Resolution: Received a DNV survey report from [name withheld], DNV surveyor, reporting that satisfactory repairs were made to the #2 steering pump.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.