← All vessels
WIGEON
Freight Ship · Bulk Carrier class · Built 2000s · USCG Great Lakes District (CGD-GL) · Other hulls named WIGEON
WIGEON is a 2007 freight ship. The Coast Guard has recorded 42 inspections since 2008, most recently in November 2025, along with 19 deficiencies and 7 operational controls.
Records from 2008 to 2025. Most recent: inspection, 8 November 2025.
- Built
- 2007
- Last inspected
- 8 November 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9358395 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5HD9
945824
Flag
LIBERIA
—
Maury page id
psix-945824
Inspections, by type
…with no type recorded11
Years with a record
15 calendar years (2008–2025)
The 42 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it22790 - Convention (Subpart B), Gross Ton
12130 - Convention (Subpart B), Net Ton
37238 - Dead Weight, Metric Ton
46960 - Displacement, Metric Ton
12130 - Convention (Subpart B), Net Ton
37238 - Dead Weight, Metric Ton
46960 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 42
8 November 2025
Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8266001
11 April 2025
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8110329
11 April 2025
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8112312
30 December 2024
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8053063
5 June 2023
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7703793
16 May 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7685174
14 May 2023
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7687905
10 May 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7685512
29 April 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7677852
26 April 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7677512
14 October 2022
PSC B
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7570319
9 October 2022
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7575957
9 June 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7472731
17 October 2021
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7335124
15 October 2021
COE-Administrative
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7333633
31 March 2021
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7166078
6 March 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7149633
27 February 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7147221
25 November 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7101878
24 September 2020
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7064035
6 July 2020
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6998055
23 June 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6722524
10 June 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6694021
1 June 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6700062
16 February 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6348918
17 November 2017
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6309970
25 April 2016
COE-Offshore
Physical examination · Station Duluth · USCG Great Lakes District (CGD-GL) · Activity 5861853
18 April 2016
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5852319
2 April 2016
Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5846667
9 September 2015
PI Safety Exam · Attraction Vessel Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5233374
20 August 2015
Ballast Water Examination · ISPS III Exam · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5219759
15 July 2015
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5182322
15 July 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5185636
23 August 2014
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4963841
21 August 2014
Administrative Inspection · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4964778
4 February 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3939084
12 March 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3432590
12 March 2009
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3432603
5 February 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3411766
6 October 2008
PII Safety Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3339713
4 October 2008
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3338692
2 October 2008
ISPS II Exam · Joint Vessel Security Verification (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3337252
Deficiency record · 19
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 May 2023
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed water leak from fresh water generator spring-loaded valve on to pump motor.
74 SOLAS (a) 2014 II-1/26.1
40ac
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2023
Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed main engine cooling fresh water valve controller not fully seated in engine control room panel.
74 SOLAS (a) 2014 II-1/40.1.3
40ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 June 2019
Resolved
13108 - Operation of machinery - Conform with present regulations to ensure vessel remains fit to The condition of the ship and its equipment shall be maintained to Proceed to sea without danger to the ship or persons on board. PSCO observed during steering test with #1 steering pump that Hydraulic Lock alarm sounded and automatically activated #2 Steering pump while trying to return rudder to amidships. 74 SOLAS (14)I/11 60a
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 10 June 2019
Resolved
11104 - Rescue Boats - Rescue boats shall be stowed in a state of continuous readiness For launching in not more than 5 min. PSCO observed fuel tank For rescue boat was empty. 74 SOLAS(14) III/14.1 10c
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 10 June 2019
Resolved
15109 - Maintenance of the ship and equipment - The company should establish procedures, plans and instructions, Including checklists as appropriate, for key shipboard operations Concerning the safety of the personnel, ship and protections of the Environment. Deficiency 02 outlines breakdown in SMS of Ensuring rescue boat is ready for operation. Corrective action Plan required prior to departure. 74 SOLAS (14) IX/3 ISM7 17a
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 June 2019
Resolved
11132 - Maintenance and inspections - Each life raft or group of life rafts shall be stowed with a float-free Arrangement complying with the requirements of paragraph 4.1.6 Of the code so that each floats free. PSCO observed all 4 life raft Hydrostatic releases expired. 74 SOLAS (14) III/13.3.4.2 17c
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 June 2019
Resolved
11132 - Maintenance and inspections - Every inflatable life raft shall be serviced at intervals not exceeding 12 months, provided where in any case this is impractical, the Administration may extend this period to 17 months. PSCO
Observed life raft servicing due 23 May 2019 & Liberia Dispensation letter Stating servicing shall be Carried out at next convenient port. 74 SOLAS (14) III/19.8.1 17c
Fire Fighting › Fire Hoses › Condition
Issued 20 August 2015
Resolved
0730 - Appliances - Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO noted approximately five different fire hose reels blocked by pipes, trash boxes, and parts. SOLAS 74 II-2 Reg. 14.1
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 20 August 2015
Resolved
0735 - Personal Equip - Ships shall carry at least two fire fighters outfits. PSCO observed one of the fire outfits Velcro for securing the outfit was completely separated. SOLAS 74 Reg. 10.1
Fire Fighting › Structural - A Class Divisions › Doors
Issued 20 August 2015
Resolved
0799 - Other - Doors fitted in boundary bulkheads in machinery spaces of cat A shall be reasonably gas tight and self closing. PSCO observed the A-60 boundary door next the boiler partially opened and the self closing assembly intentionally removed rendering the self closing assembly inoperative. SOLAS 74 II-2 Reg 9.4.2.1
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 20 August 2015
Resolved
1499 - Other - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed the securing pins missing on the boiler relief valves.
Operations/Management › Pollution › Control of Garbage
Issued 20 August 2015
Resolved
2120 - Garbage - The ships garbage management plan shall provide written procedures for collecting, storing, processing, and disposing of garbage. PSCO noted several used boxes, container, oil soaked filters, rags, and empty drums throughout the engine room. MARPOL Annex V Reg. 9.2
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 July 2015
Resolved
1790 - ship type designation - annex 1 - ran oil filtering equipment, no sample being fed to Oil Content Meter due to blocked sample line. Discharge was passing three-way valve allowing overboard to appear to contain oil. crew cleared sample line with screwdriver and system unable to drop ppm of discharge to below 15 ppm.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 July 2015
Resolved
1799 - Other (MARPOL ANNEX 1) - when running oil water separator, crew not familiar with proper testing procedures as evident by not checking that no effluent was reaching the OCM, the crew opened the sample line leading from discharge line of the OWS to the OCM and stuck a screwdriver into the opening.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 15 July 2015
Resolved
0615 - Rescue Boats - The crew took over 20 minutes to start the rescue boat after prompting by the PSCO. The 2nd officer had to contact the engineers to clean the spark plug and drain fuel line to then try again to finally get the boat started.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 15 July 2015
Resolved
0725 - fixed fire extinguishing installation - discharge valve of localized water spray system in the closed position. This prohibits the system from being remotely operated in the fire control station.
Personnel › Training › Crude Oil Washing Operations
Issued 15 July 2015
Resolved
2510 - safety and environmental policy - Due to objective evidence found in deficiencies 01, 02, 03, 04, 06, 07 the PSCO believes there are clear grounds for believing that the Master and crew are not familiar with essential shipboard procedures relating to the safety of ships.
Engineering › Fuel Oil Service System › Piping
Issued 15 July 2015
Resolved
0750-Fire prevention-The engineering crew had disabled the leak alarm on the main engine fuel return line due to standing fuel in the fuel return line. 74SOLASII-2
Electrical › Electric Generation Source (emergency) › Generator
Issued 15 July 2015
Resolved
9800-Other (clearly hazardous)-A second source of energy shall be provided for an additional three starts within 30 min unless manual starting can be demonstrated to be effective. The crew was unable to start the emergency generator using the secondary means of starting after three attempts. 74SOLASII-1/44.2
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.