Records from 2012 to 2025. Most recent: inspection, 26 September 2025.
Inspection history · 52
26 September 2025
Cargo Tank Internal · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8244145
29 January 2025
COI Inspection · Vessel Attendance · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8063479
17 December 2024
Administrative Inspection · Exemption
Administrative · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 8048328
25 November 2024
MARPOL Annex VI Survey · Exemption · Ballast Water Examination · MARPOL Annex I Examination · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex IV Survey · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8039606
28 October 2024
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8025868
4 October 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8014299
13 August 2024
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7982542
12 June 2024
Construction Oversight · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7938865
26 December 2023
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7847660
4 December 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7833078
24 October 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7813399
2 October 2023
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7802118
14 August 2023
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7767750
21 July 2023
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7748698
21 July 2023
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7749623
2 July 2023
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7728783
22 May 2023
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7694193
17 April 2023
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7670410
11 March 2023
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7647426
27 February 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7642713
25 February 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7641815
20 January 2023
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7630396
17 January 2023
Deficiency Check · MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7622211
13 January 2023
Deficiency Check · Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7621017
8 November 2022
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7592410
22 July 2022
Appeal · Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7537948
18 January 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7382007
13 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7255060
1 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7241358
19 May 2021
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7201111
14 May 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7196894
16 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7176679
6 April 2021
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7169620
1 April 2021
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7166846
22 December 2020
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7115086
13 October 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7076282
13 October 2020
In-Service Inspection · ISM Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7076366
2 August 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7022975
30 July 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7019818
17 July 2020
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7008495
10 July 2020
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7015762
26 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6960596
21 November 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6862190
18 November 2019
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6860170
8 October 2019
In-Service Inspection · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6828323
25 October 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6568028
8 October 2018
Construction Oversight · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6559342
24 July 2018
Administrative Inspection · MARPOL Annex IV Survey · MARPOL Annex I Examination · MTSA/ISPS Verification · MARPOL Annex V Examination · Deficiency Check · COI Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6488341
20 June 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6450123
5 December 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6318286
20 July 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6215437
13 December 2016
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6318893
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 August 2023
Resolved
Each self propelled vessel and each MODU must have at least two electric generating sources. STBD generator prime mover experienced a high J/W temp. shutdown when running at the pier. Trouble shoot and repair prior to placing in service to the satisfaction of the attending MI.
46 CFR 111.10-3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 August 2023
Resolution: Replaced J/W pump, belt and pulleys with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 July 2023
Resolved
In addition to the emergency power sources required under part 112 of this chapter, each self propelled vessel must have at least two electric generating sources. The port SSDG had a leak coming from the Hydraulic Electronic Unit Injection Pump (HEUI) that controls the f/o injectors on the prime mover. Vessel is to return to Port Canaveral and effect repairs to the satisfaction of the attending MI.
46 CFR 111.10-3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2023
Resolution: Reviewed tech report, tested Port SSDG under load and inspected components, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 February 2023
Resolved
All marine engineering details such as piping, valves, fittings, boilers, pressure vessels, etc., and their appurtenances installed on the vessel, shall be designed, constructed, and installed in accordance with the provisions of subchapter F (Marine Engineering) of this chapter.
Duty MI received a report that the vessel experienced stbd engine reduction gear failure from faulty pressure sensor resulting in the securing of the main engine and loss of approximately 2-3 gallons of lube oil.
46 CFR 90.20-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2023
Resolved 26 February 2023
Resolution: MI attended vessel and witnessed the satisfactory operation of starboard engine/reduction gear.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 February 2023
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS Steel Vessel Rules (incorporated by reference, see 46 CFR 58.03-1), except as otherwise provided by this subchapter.
Shaft tach is required by the above and was inoperable after replacing tail shafts.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 22 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 February 2023
Resolved
Minimum instrumentation, alarms, and safety controls required for specific types of automated vital systems are listed in Table 62.35-50.
Port gen high J/W temp sensor was not indicating on alarm panel while ECM read a high J/W temp.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 16 March 2023
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 16 February 2023
Resolved
Piping systems and appurtenances not requiring plan approval may be accepted by the marine inspector if: (a) The system is suitable for the service intended.
P/W pumps are supported by piping and not bolted to mounts
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 22 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2023
Resolved
Equipment for interior locations not requiring exceptional degrees of protection must be manufactured to at least NEMA 250 Type 1 with drip shield or IEC 60529 IP 11 as specified in IEC 60529.
Battery charger near switch board missing drip shield.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 16 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2023
Resolved
Each cable splice must be made in accordance with section 25.11 of IEEE 45-2002 (incorporated by reference; see 46 CFR 110.10-1).
Dead end wires present on top of pilot house stbd side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2023
Resolved 16 March 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 January 2023
Resolved
The markings required (Vessel Name) must be made in
clearly legible letters of the Latin alphabet or Arabic
or Roman numerals not less than four inches in height.
Vessel Name and hailing port both are marked in
lettering less than four inches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2023
Resolved 2 February 2023
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 17 January 2023
Resolved
Vessels operated solely within one hundred nautical
miles of shore must be equipped with a medium frequency
transmitter capable of transmitting J3E emission and a
receiver capable of reception of J3E emission within the
band 1710 to 2850 kHz...Additionally, such vessels must
be equipped with a single sideband radiotelephone
capable of operating on all distress and safety
frequencies in the medium frequency and high frequency
bands. Single sideband radio not capable of being tuned
and/or functioning properly.
47 CFR 80.880(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 16 February 2023
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 January 2023
Resolved
An illuminated magnetic steering compass, mounted in a
binnacle, that can be read at the vessel's main steering
stand. Compass Light not functioning.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 16 February 2023
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 January 2023
Resolved
A current magnetic compass deviation table or graph or
compass comparison record for the steering compass, in
the wheelhouse. Deviation table updated prior to
installation of new owner's electronic array.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 16 February 2023
Resolution: Compass was adjusted and deviation card issued.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 January 2023
Resolved
The lights prescribed by these Rules shall, if carried,
also be exhibited from sunrise to sunset in restricted
visibility and may be exhibited in all other
circumstances when it is deemed necessary. Port Side
Navigation Light inoperable.
Action required: 10 - Deficiency Rectified
Due 24 January 2023
Resolved 17 January 2023
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 January 2023
Resolved
If portable fire extinguishers are not located in the
open or behind glass so that they may be readily seen,
they may be placed in enclosures together with the fire
hose, provided such enclosures are marked as required by
§ 97.37-15 of this subchapter. Portable "Class D"
portable F/E not mounted nor in location depicted on
Fire Control Plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 2 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 January 2023
Resolved
An aggregate of more than 7.6 liters (two gallons) of
flammable or combustible liquids stowed outside of an
accommodation, control, or service, space (other than a
paint locker) or outside of a machinery space must be
stowed in a paint locker that is marked with a warning
sign indicating flammable or combustible liquid storage.
Paints and other flammables not stowed in a cabinet
marked with required warning nor could it be confirmed
that the cabinet was constructed IAW 29 CFR 1910.106(d)
(3) by UL 1275 label.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 16 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 January 2023
Resolved
The nameplate (on pressure vessel) shall be maintained
in a legible condition such that it may be easily read.
Nameplate on pressure vessel outside on the main deck
has been painted and needs to be entered on COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 16 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2023
Resolved
Each outlet and junction box must be suitable for the
environment in which it is installed and be constructed
to the appropriate NEMA or IEC standard. Outlets on main
deck are not weatherproof with plug inserted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 16 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 January 2023
Resolved
Each combination solid stream and water spray firehose
nozzle required to be approved under the provisions of
this subpart must be tested accordance with the
requirements of ASTM F 1546 or NFPA 1964. Leakage
through any part of the nozzle other than the discharge
orifice shall not be permitted. Nozzle for hose at
station on main deck leaks excessively.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 16 February 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2023
Resolved
Exposed, noncurrent-carrying metal parts of fixed
equipment that may become energized because of any
condition must be grounded. Grounding wire to metallic
switch housing for "PNL HA FEED", on main deck, stbd was
disconnected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 2 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 January 2023
Resolved
For each connected generator, each switchboard must have
an ammeter with a selector switch that connects the
ammeter to show the current in each phase. Ammeters for
both gensets inoperable.
Action required: 10 - Deficiency Rectified
Due 24 January 2023
Resolved 17 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 17 January 2023
Resolved
The material, design, construction, workmanship, and
arrangement of main propulsion machinery...must be at
least equivalent to the standards established by the ABS
Steel Vessel Rules. For propulsion machinery intended
for centralized or unattended operations, alarms for
abnormal conditions of the cooling media and automatic
safety systems functions are provided. Keel cooler
expansion tank for STBD SSDG Low Level Alarm inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2023
Resolved 22 March 2023
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 17 January 2023
Resolved
The material, design, construction, workmanship, and
arrangement of main propulsion machinery...must be at
least equivalent to the standards established by the ABS
Steel Vessel Rules. Hot surfaces likely to come into
contactwith the crew during operation are to be suitably
guarded or insulated....Noted a missing section of
exhaust lagging on both MDEs IWO aft tunnel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 16 February 2023
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 January 2022
Resolved
The inspection process shall ensure that a vessel subject to inspection complies with applicable marine safety laws and regulations. During annual inspection it was discovered that the vessel was previously sold and a Certificate of Documentation issued with new owner and vessel name. All required certificates, documents, manuals, plans, lifesaving equipment and the vessel hull remain marked with, approved for, or issued to the previously named vessel. Ensure all updates are complete to reflect accurate identification of vessel and owner.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2022
Resolved 30 June 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 May 2021
Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work as noted in 46 CFR 91.55-5. Submit updated stability plans and documentation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2021
Resolved 21 June 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2021
Resolved
The gross and net tonnage and dimension of a vessel must be determined whenever there is a change in the gross or net tonnage or dimensions of a documented vessel. Provide a tonnage determination to OCMI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2021
Resolved 7 July 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2021
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery or equipment shall be made without the knowledge of the [name withheld] of alterations shall be approved before work is started. An aesthetic fiberglass bulkhead constructed of unapproved materials has been installed without OCMI oversight or Coast Guard approval.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2021
Resolved 8 April 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 December 2020
Resolved
All machinery capable of injuring personnel shall be provided with adequate covers or guards. Properly repair or renew insulating blankets on both main diesel engines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 January 2021
Resolved 6 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 August 2020
Resolved
Vessel is to proceed directly to Port Canaveral, FL from Pensacola, FL to effect repairs on the starboard ship's service generator. Vessel shall notify local Coast Guard upon arrival. Vessel has ten days to transit or earlier to make report.
Action required: 705 - Other - as specified
Resolved 13 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020
Resolved
Vessel is required to have two ship's service generators. The starboard generator is inoperable. Vessel shall provide a standby generator while transiting from Pensacola, FL o Port Canaveral, FL. Upon arrival, vessel shall make permanent repairs to the satisfaction of the local Coast Guard Inspector, and prior to operation.
Action required: 705 - Other - as specified
Resolved 13 October 2020
Resolution: Resolved to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2020
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. Vessel may not depart the Port of Pensacola until temporary generator installation has been inspected by a Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2020
Resolution: Completed survey and allowed vessel to transit one way to Port Canaveral, FL to effect repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 November 2019
Resolved
Complete audit of the Company Drug and Alcohol Program.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2019
Resolved 6 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 November 2019
Resolved
Provide current compass deviation card.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 December 2019
Resolved 18 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 July 2018
Resolved
Provide and install a Coast Guard approved rescue boat with appropriate equipment and launching devices. In the interim, the crew has demonstrated satisfactory use of the rescue platform that will allow for transit from Fourchon, LA to Port Canaviral, FL.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2018
Resolved 1 August 2018
Resolution: 835 rescinded after discussions between the two inspection zones (D7 and D8).