Records from 2016 to 2026. Most recent: inspection, 28 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)45.0 ft × 12.0 ft × 4.0 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRIDENT FLORIDA TRADING LLC · TAVARES, FL, UNITED STATES · built 2008
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portFAIRHOPE, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
16 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 16
28 April 2026
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8314376
26 February 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8276574
25 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8099567
28 November 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7830815
19 May 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7692381
8 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7633340
5 July 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7503842
9 February 2022
Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7393376
19 March 2021
Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7161835
16 January 2019
Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611316
16 January 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6611329
2 May 2018
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6346033
10 January 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6068952
9 January 2017
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6068161
18 April 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5857037
24 February 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5821427
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2026
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 or be specifically approved by the Commandant. MI observed non-marine-grade flexible nonmetallic hoses in use on the vessel's fuel system.
Cite: 46 CFR 182.455(a)(1)(iii)
46 CFR 182.720(e)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2026
Resolution: Vessel installed Parker 221FR-6 marine fuel hoses and AWAB/ABA 316 SS non perforated clamps. Alhough the markings on them read as SAE J1527 A1, they are also SAE J1942 compliant, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 6 February 2024
Resolved
vessel subject to Part III of title III of the 46 CFR 50 communications act must have a detailed inspection of radio installation by an FCC licensed tech every 5 years and issued a safety radiotelephony certificate, vessels radiotelephony cert was expired. Provide current FCC radiotelephony cert. Vessel restricted to 1000' from shore.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 April 2024
Resolved 15 April 2024
Resolution: Amended COI route to restrict vessel to 1000' from shore.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 February 2022
Resolved
Nav Lights inoperable. Starboard light missing. Nav Lights must comply with applicable rules. Repair/Replace
33CFR83.23
Allowed to operate in daylight only and no forecast of low visibility.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2022
Resolved 8 June 2022
Resolution: Light fixed, see photo.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 10 February 2022
Resolved
Missing 2 orange disress signals. Vessels on L/B/S route must have 3 red/3 orange signals. Replace.
46CFR180.68
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 8 June 2022
Resolution: Photo received of sat flares, see photo.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2022
Resolved
Adult Life Jackets storage not labeled for 2 life jackets added. Label new storage location.
46CFR180.71/185.604
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 8 June 2022
Resolution: Labeled, see photo.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 February 2022
Resolved
Starboard fuel tank missing double clamps on hose. Flexible hose used for fuel must be installed with two hose clamps at each end. Add one additional clamp to each end.
46CFR182.720
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 22 March 2022
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 February 2022
Resolved
Leak in weld seam of rear/starboard pontoon. Repair.
46CFR177.300
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2022
Resolved 22 February 2022
Resolution: Ground out cracked weld, rewelded. Conducted leak test IAW local SOP. No leaks detected.
Construction/Loadline › Structures › Superstructure
Issued 18 April 2017
Resolved
Repair overhead supports/stanchions # 2 and #3 on the port side. See attached pictures.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 2 May 2018
Resolution: Dented supports removed and replaced with new stanchions on port side.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 March 2016
Resolved
Vessel did not have a current Certificate of Documentation onboard. Provide a current Certificate of Documentation. IAW 46 CFR 67.7
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 18 April 2016
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 March 2016
Resolved
Vessel's PFD's and Ring Buoy were only stenciled with part of the vessel's name ("EXPLORER"). Stencil all PFD's and Ring Buoy with the full vessel name ("WEEKS BAY EXPLORER"). IAW 46 CFR 185.604.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 18 April 2016
Documentation › Markings/Placards › Oil Discharge Placard
Issued 14 March 2016
Resolved
Vessel did not have an 'Oil Discharge' placard onboard. Obtain an 'Oil Discharge' placard and post onboard. IAW 33 CFR 155.450
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 18 April 2016