GOLIATH
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named GOLIATH
GOLIATH is a 2000 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2008, most recently in July 2026, along with 12 deficiencies and 1 operational control.
Records from 2008 to 2026. Most recent: inspection, 23 July 2026.
- Built
- 2000
- Last inspected
- 23 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1271948
WDA3796
946550
Flag
UNITED STATES
368212270
Maury page id
psix-946550
Inspections, by type
…with no type recorded1
Years with a record
11 calendar years (2008–2026)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 14.9 ft × 5.3 ft
Registered tonnagegross 19 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portPOMPANO BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Simplified, Gross Ton
15 - Simplified, Net Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM5068MMSI 368212270 · active · compulsorily equipped · granted 28 July 2021, expires 28 July 2031
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 17
23 July 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8444971
13 November 2025
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8268165
19 November 2024
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8036807
13 May 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7922533
16 January 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7855363
27 January 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7627902
12 July 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7503971
20 September 2021
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7316116
19 February 2021
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7142820
22 July 2020
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7012955
14 January 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6889048
19 July 2019
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6759269
19 December 2018
Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6600662
4 October 2018
Deficiency Check · DAPI Audit · Initial Certification
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6554557
16 July 2018
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6481529
31 October 2017
Plan Review "T" Boat · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6465278
6 October 2008
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 3339753
Deficiency record · 12
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 13 November 2025
Resolved
46 CFR 181.420 A pre-engineered fixed gas fire extinguishing system must: A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Fireboy override switch inoperable.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 13 November 2025
Resolved
46 CFR 182.430 Exhaust gas must not leak from piping or any connections. Exhaust leak detected on muffler.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2025
Resolved
46 CFR 181.520 Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Portable extinguisher at operating station was stored inside seat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 November 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. High level alarm in STBD/FWD Engine Space was not activating or operating. Repair/Replace to the satisfaction of CG Marine Inspector.
46 CFR 182.530
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 November 2024
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. All gauges inoperable. Repair/Replace to the satisfaction of CG Marine Inspector.
46 CFR 182.410 (b)
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 November 2024
Resolved
(1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Missing 3 red disrtress flares. Repair/Replace to the satisfaction of CG Marine Inspector.
46 CFR 180.68
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2024
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Bilge pump distribution box in STBD/FWD Engine Space missing front cover plate.
46 CFR 183.330 (b)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 16 January 2024
Resolved
Fuel Piping The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
46 CFR 182.455
Repair or replace starboard remote fuel shutoff vavle.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 January 2023
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 February 2020
Resolved
Machinery space high level alarm inoperative. Repair/replace alarm. 46 CFR 182.530
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 February 2020
Resolved
Provide FCC Safety Certificate; restricted to no more than 1000 feet from shore. 47 CFR 80
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 14 February 2020
Resolved
VHF not showing location. Program radio to indicate vessel's location. 47 CFR 80