CLIPPER TENACIOUS

CLIPPER TENACIOUS is a 2007 freight ship. The Coast Guard has recorded 20 inspections since 2008, most recently in February 2019, along with 8 deficiencies and 4 operational controls.

Records from 2008 to 2019. Most recent: inspection, 20 February 2019.

Built
2007
Last inspected
20 February 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9320348 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
946581
Flag
MARSHALL ISLANDS
—
Maury page id
psix-946581

Inspections, by type

…with no type recorded6
Years with a record 9 calendar years (2008–2019)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19918 - Convention (Subpart B), Gross Ton
10477 - Convention (Subpart B), Net Ton
30634 - Dead Weight, Metric Ton
38557 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

20 February 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6628849
28 November 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6313963
24 May 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5884014
14 March 2016 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5832569
14 September 2015 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5717692
15 January 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4222905
14 January 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4229557
11 January 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4223205
26 July 2011 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4094616
8 July 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4066326
7 July 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4066331
29 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3672172
29 January 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3672742
29 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4149115
18 December 2009 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3652700
12 May 2009 MARPOL Annex VI Survey · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3470316
9 May 2009 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3470993
22 March 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3437874
9 November 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3360085
8 May 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3201984

Deficiency record · 8

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 November 2017 Resolved
Code:0750, Cite:74SOLAS(14)II-2/9.4.1.1.5.4, Action:10c - Fire doors in main vertical zone bulkheads, galley boundaries and staiway enclosures other than power-operated watertight doors and those which are normally locked shall satisfy the following requirements: Hold-back hooks not subject to central control station release are prohibited. All self-closing doors in the galley area had hold-back hooks.
Action required: 705 - Other - as specified
Due 28 November 2017
Resolved 28 November 2017
Resolution: All hold-back hooks were removed by the crew.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 28 November 2017 Resolved
Code:1499, Cite:74SOLAS(04)I/11(a), Action:10c - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. During test of emergency generator, engine would start, but immediately shut-off. This was due to E-Stop which was engaged without crew knowledge.
Action required: 705 - Other - as specified
Due 28 November 2017
Resolved 28 November 2017
Resolution: Engine started and operated normally after E-Stop was reset.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 24 May 2016 Resolved
Code: 0725: The following fire protection systems shall be left in good order so as to ensure their required performance if a fire occurs. The fire alarm systems, the water mist systems fire alarm panel is not operational. SOLAS 74(14) II-2/14-2.I.I.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2016
Resolution: Received Class Report attesting to proper repairs.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 May 2016 Resolved
Code: 1730:PSCO Observed excessive water leaking from the base of oily water separator equipment preventing an operational test of the system. Cite: MARPOL 73/78 Annex I/4.4.a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2016
Resolution: Received Class Report attesting to proper repairs.
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 January 2012 Resolved
The Radar was reported not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2012
Resolved 19 January 2012
Resolution: Received, reviewed and accepted tech report from [name withheld] stating the SPU PCB was replaced with a new one.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 8 July 2011 Resolved
0735 - Personal equipment-fire fighting - A fire-fighter's outfit shall consist of protective clothing of material to protect the skin from the heat radiating from the fire. During inspection of both fire-fighting outfits, PSCO observed flaking and deterioration-SOLAS II-2/10.10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 July 2011
Resolved 26 July 2011
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating two suitable sets of fire-fighting outfits were supplied to the vessel located in the accommodation upper deck.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 July 2011 Resolved
1740 - Oil Discharge Mon/control systems - Ships 10000gt and above shall be fitted with a oil content meter. Ships staff training should include familiarization in the operation and maintenance of the equipment. Ships engineering staff was unaware of OCM data logger retrieval function. MARPOL Annex I, Reg 14, MEPC 107(49) 1.1.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 8 July 2011
Resolved 26 July 2011
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating training was conducted and crew was familiarized with Oil Content Meter.
Engineering › Steering Gear System › Rudder
Issued 29 January 2010 Resolved
The vessel experienced a steering irregularity while in the Mississippi River.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 January 2010
Resolved 30 January 2010
Resolution: Received, reviewed and accepted class report from ABS stating the steering gear was repaired, tested and found satisfactory.