MAURY USCG vessel records
← All vessels

MS KRISTIE

MS KRISTIE is a 2008 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in September 2022, along with 5 deficiencies and 1 casualty investigation in 2011.

Records from 2011 to 2022. Most recent: inspection, 16 September 2022.

Built
2008
Last inspected
16 September 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 September 2022
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9556234
WDE5516
946850
Flag
UNITED STATES
Maury page id
psix-946850

Documentation record

Tonnage as PSIX records it339 - Convention (Subpart B), Gross Ton
86 - Regulatory (Subpart C or D), Gross Ton
101 - Convention (Subpart B), Net Ton
59 - Regulatory (Subpart C or D), Net Ton
288 - Dead Weight, Ton
453 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

16 September 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7560342
17 August 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7536716
14 June 2022 Type not recorded
No type recorded · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7562733
27 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7206520
5 November 2020 Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7090454
21 August 2020 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7044768
7 May 2020 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6949857
15 March 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6642317
20 April 2018 Administrative Inspection · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6400166
29 September 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6277725
17 March 2016 Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5835239

Deficiency record · 5

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2022 Resolved
Vessel must carry one floating waterlight unless limited to daytime operations IAW 161.010. The vessel's floating waterlight battery was expired (05/20). 705 - Daytime operations only.
Action required: 705 - Other - as specified
Resolved 19 August 2022
Resolution: New batteries were installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 August 2022 Resolved
Each buoyant apparatus must have an floating waterlight IAW 161.010. All of the vessel's floating waterlight had expired batteries (05/20). 705 - Daytime operations only.
Action required: 705 - Other - as specified
Resolved 19 August 2022
Resolution: New Batteries were installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 August 2022 Resolved
A 40B portable fire extinguisher installed outside the space may be substituted for a fixed gas system for a paint locker if the applicator must be installed to discharge into the space protected. Vessel did not have the fire extinguisher connected to the discharge directly into the paint locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2022
Resolved 19 August 2022
Resolution: new hose was installed to connect FE and Paint Locker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 August 2022 Resolved
All machinery and equipment must be installed and maintained to afford adequate protection from causing fire. Vessel's Port Generator was missing a bolt on the retaining bracket for a high pressure fuel line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2022
Resolved 19 August 2022
Resolution: Bolt was secured to retain HP Fuel line.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 17 August 2022 Resolved
All machinery and equipment must be installed and maintained to afford adequate protection from causing from machinery failure and personnel injury. The stbd steering had a 15 degree variance at 30 degree port and over 5 degree variance at other rudder orders.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2022
Resolved 19 August 2022
Resolution: Tech replaced old boards. Steering issued corrected per tech report.

Casualty record · 1

18 October 2011Routine · role: Involved in a Marine Casualty · activity 4173206
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.