MAURY USCG vessel records Sign in
← All vessels

MINERVA CLARA

MINERVA CLARA is a 2006 tank ship. The Coast Guard has recorded 19 inspections since 2008, most recently in March 2022, along with 7 deficiencies and 3 operational controls.

Records from 2008 to 2022. Most recent: inspection, 8 March 2022.

Built
2006
Last inspected
8 March 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9297333 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
946873
Flag
GREECE
—
Maury page id
psix-946873

Inspections, by type

…with no type recorded3
Years with a record 12 calendar years (2008–2022)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it58156 - Convention (Subpart B), Gross Ton
31033 - Convention (Subpart B), Net Ton
122142 - Displacement, Metric Ton
103232 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

8 March 2022 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7402693
6 August 2020 COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7021554
9 December 2019 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6864744
29 September 2019 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6819312
3 January 2019 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6605217
2 August 2018 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6498552
6 October 2017 COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6282828
4 October 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6281255
14 June 2017 ISPS III Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6167938
28 October 2016 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6031123
24 October 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6028749
14 July 2016 ISPS II Exam · COC-TVE Renew · Administrative Inspection · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5940177
13 October 2015 Deficiency Check · COE-Dockside · COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5722689
17 August 2014 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4957396
12 August 2011 ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4105739
26 November 2010 COE-Dockside
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3895390
6 November 2010 Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 3886219
12 July 2009 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3531995
8 May 2008 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3196740

Deficiency record · 7

Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 14 July 2016 Resolved
1840-Instrumentation-Suitable means shall be provided for the zero & span calibration of both fixed & portable gas concentration measurement instruments. Nitrogen bottles for the O2 analyzer are unsat. One is empty and other is expired. FSS Code 15.2.4.2.5
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2016
Resolved 19 July 2016
Resolution: Received, reviewed and accepted documentation provided from the vessel showing delivery of new span gas bottles photos of them installed and calibration on board.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 July 2016 Resolved
1820-Pump Room-After any survey of the ship has been completed no change shall be made in the structural arrangements machinery equip and other items covered by the survey without approval of administration. PSCO observed cement plugs over 2 lightning holes in 2 adjacent stringers in the bilge of the pump room. SOLAS I/11
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 28 October 2016
Resolution: Received class report stating cement plugs have been removed in pump room. Class report attached.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 July 2016 Resolved
1899-Other-After any survey of the ship has been completed no change shall be made in the structural arrangements machinery equip and other items covered by the survey without approval of administration. Numerous valve indicators on deck painted over making the indication no longer visible. SOLAS I/11
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 28 October 2016
Resolution: Received class report stating valve indicators on deck were properly painted. See report.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 14 July 2016 Resolved
1840-Instrumentation-A system for cont monitoring if the concentration of hydrocarbon gas shall be fitted for the pump room. Hydrocarbons were measured at 4% on the ships fixed sampling equipment. Marine Chemist certificate showed 0% and portable sampling equipment on board showed 0%. SOLAS II-2/4.5.10.1
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 14 July 2016
Resolution: PSCO witnessed calibration of equipment tested and found satisfactory. Cleared DF on the spot.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 13 October 2015 Resolved
EACH EMERGENCY GENERATING SET ARRANGED TO BE AUTOMATICALLY STARTED SHALL BE EQUIPED WITH STARTING DEVICES APPROVED BY THE ADMINISTRATION WITH A STORED ENERGY CAPACITY OF AT LEAST THREE CONSECUTIVE STARTS. PSCO OBSERVED VESSEL'S EMERGENCY GENERATOR WAS UNABLE TO START AUTOMATICALLY ON BATTERY POWER. SOLAS 2004 CONS. 0999 II-I/44.2 17C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2015
Resolved 15 October 2015
Resolution: Emergency generator engine starting batteries were renewed as original. Witnessed starting operation of emergency generator engine on battery source of power.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 13 October 2015 Resolved
EVERY SHIP OF 400GT AND ABOVE SHALL BE PROVIDED WITH A TANK OR TANKS OF ADEQUATE CAPACITY HAVING REGARD TO THE TYPE OF MACHINERY AND LENGTH OF WHICH TO RECEIVE THE OIL RESIDUES WHICH CANNOT BE DEALT WITH OTHERWISE IN ACCORANCE WITH THE REGULATIONS OF THIS ANNEX. PSCO OBSERVED HIGH TEMPERATURE COMBUSTION ALARM PREVENTED THE INCINERATOR FROM FUNCTIONING AS REQUIRED BY IOPP FORM A. MARPOL I/12.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 October 2015
Resolved 14 July 2016
Resolution: Vessel provided class report to PSCO while on board. PSCO reviewed and accepted the documentation provided.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 13 October 2015 Resolved
THE OPERATOR OF A VESSEL WITH A CAPACITY OF 250 OR MORE BARRELS OF OIL, HAZARDOUS MATERIAL, OR LIQUIFIED GAS AS REGULATED IN TABLE 4 OF 46 CFR PART 154 SHALL PROVIDE TRANSFER PROCEDURES THAT MEET THE REQUIREMENTS OF THIS PART OF PART 156 OF THIS CHAPTER FOR TRANSFERING. PSCO OBSERVED TRANSFER PROCEDURES WERE INCOMPLETE WITH THE REQUIREMENTS IN 33 CFR 155.750. 9990 33CFR155.720 60 DAYS C
Action required: 705 - Other - as specified
Due 13 December 2015
Resolved 14 July 2016
Resolution: PSCO reviewed and accepted transfer procedures on board.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.