MINERVA CLARA is a 2006 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in March 2022, along with 4 deficiencies and 2 operational controls.
Records from 2016 to 2022. Most recent: inspection, 8 March 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it58156 - Convention (Subpart B), Gross Ton 31033 - Convention (Subpart B), Net Ton 122142 - Displacement, Metric Ton 103232 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
8 March 2022PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7402693
6 August 2020COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7021554
9 December 2019In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6864744
29 September 2019ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6819312
3 January 2019COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6605217
2 August 2018Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6498552
6 October 2017COE-Offshore
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6282828
4 October 2017Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6281255
14 June 2017ISPS III Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6167938
28 October 2016Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6031123
24 October 2016Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6028749
14 July 2016ISPS II Exam · COC-TVE Renew · Administrative Inspection · Deficiency Check · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5940177
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 14 July 2016Resolved
1840-Instrumentation-Suitable means shall be provided for the zero & span calibration of both fixed & portable gas concentration measurement instruments. Nitrogen bottles for the O2 analyzer are unsat. One is empty and other is expired. FSS Code 15.2.4.2.5
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2016
Resolved 19 July 2016
Resolution: Received, reviewed and accepted documentation provided from the vessel showing delivery of new span gas bottles photos of them installed and calibration on board.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 July 2016Resolved
1820-Pump Room-After any survey of the ship has been completed no change shall be made in the structural arrangements machinery equip and other items covered by the survey without approval of administration. PSCO observed cement plugs over 2 lightning holes in 2 adjacent stringers in the bilge of the pump room. SOLAS I/11
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 28 October 2016
Resolution: Received class report stating cement plugs have been removed in pump room. Class report attached.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 14 July 2016Resolved
1899-Other-After any survey of the ship has been completed no change shall be made in the structural arrangements machinery equip and other items covered by the survey without approval of administration. Numerous valve indicators on deck painted over making the indication no longer visible. SOLAS I/11
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 28 October 2016
Resolution: Received class report stating valve indicators on deck were properly painted. See report.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 14 July 2016Resolved
1840-Instrumentation-A system for cont monitoring if the concentration of hydrocarbon gas shall be fitted for the pump room. Hydrocarbons were measured at 4% on the ships fixed sampling equipment. Marine Chemist certificate showed 0% and portable sampling equipment on board showed 0%. SOLAS II-2/4.5.10.1
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 14 July 2016
Resolution: PSCO witnessed calibration of equipment tested and found satisfactory. Cleared DF on the spot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.