BULLDOG is a 1944 towing vessel. The Coast Guard has recorded 14 inspections since 2008, most recently in May 2025, along with 25 deficiencies and 1 operational control.
Records from 2008 to 2025. Most recent: inspection, 15 May 2025.
- Built
- 1944
- Last inspected
- 15 May 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1211511
WDK4743
946887
Flag
UNITED STATES
367777110, 368058270
Maury page id
psix-946887
Inspections, by type
…with no type recorded2
Years with a record
10 calendar years (2008–2025)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)77.1 ft × 23.0 ft × 10.3 ft
Registered tonnagegross 142 / net 96
ITC dimensions (L × B × D)77.1 ft × 23.0 ft × 10.3 ft
ITC tonnageNot recorded
BuilderEQUITABLE EQUIPMENT COMPANY INC · MADISONVILLE, LA, UNITED STATES · built 1944
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLA CROSSE, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it142 - Regulatory (Subpart C or D), Gross Ton
96 - Regulatory (Subpart C or D), Net Ton
96 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK4743MMSI 368058270 · active · compulsorily equipped · granted 13 September 2018, expires 13 September 2028
WDJ4375MMSI 367777110 · active · compulsorily equipped · granted 14 March 2017, expires 14 March 2027 · licensed under a name not among this hull’s recorded names (not shown)
WDE7069MMSI 367388570 · expired · compulsorily equipped · granted 19 December 2008, cancelled 23 February 2019 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 14
15 May 2025
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8133366
5 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8029790
16 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7809455
13 September 2023
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7790763
17 April 2023
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7671489
10 June 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7473563
2 December 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7360873
28 October 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7086429
7 November 2019
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6851515
22 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6690880
6 April 2018
Initial Certification · Uninspected Other · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6408981
29 April 2009
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3464717
12 December 2008
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3402670
18 September 2008
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3327257
Deficiency record · 25
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 15 May 2025
Resolved
Towing vessel must carry at least one appropriate-size immersion suit for each person onboard; seams of one immersion suit were deteriorating, repair or replace. Limited to five total POB until rectified.
46 CFR 141.350
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2025
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires, ensuring that the design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design, NICET level IV tech, or authorized class society; required certification was not available.
46 CFR 142.330(a)(7)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2025
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with COLREGS; vessel did not have any dayshapes; acquire minimum of 3 ball and 1 diamond dayshape.
46 CFR 140.720
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2025
Resolved
Electrical equipment must be marked with its respective current and voltage ratings; distrib panels not marked with rated load of each circuit. Label circuit directory with rated load, ensure no breaker exceeds rated load.
46 CFR 143.400
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 May 2025
Resolved
The following list of items must be recorded in the TVR, official logbook:
(1) Personnel records, in accordance with § 140.400;
(2) Safety orientation, in accordance with § 140.410;
(3) Record of drills and instruction, in accordance with § 140.420;
(4) Examinations and tests, in accordance with § 140.61(5) Operative navigational safety equipment, in accordance with § 140.620;
(6) Navigation assessment, in accordance with § 140.635;
(7) Navigation safety training, in accordance with § 140.645;
(8) Oil residue discharges and disposals, in accordance with § 140.655;
(9) Record of inspection of towing gear, in accordance with § 140.820; and
(10) Fire-detection and fixed fire-extinguishing, in accordance with § 142.240.
Not all items were readily locatable during inspection; correct by next topside.
46 CFR 140.915
08 - Alarms › N/A - No Subsystem › General alarm
Issued 15 May 2025
Resolved
Each towing vessel must be fitted with a general alarm; GA was not operational.
46 CFR 143.235(b)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 November 2024
Resolved
Vessel was unable to complete Annual Inspection, within 3 months of it's anniversary date, due to crew-availability shortfalls at end of the 2024 season. Vessel is laid-up in Duluth, MN for the winter. Vessel may not operate commercially until a Certificate of Inspection (COI) has been satisfactorily completed (anticipate Spring 2025).
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 10 June 2022
Resolved
Each liferaft must have a painter system providing a connection between the vessel and the liferaft. The painter for the liferaft is not connected to the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 10 June 2022
Resolved
The owner or managing operator of a towing vessel must establish procedures to address fall overboard prevention and recovery of persons in the water, including, but not limited to use of retrieval equipment. The crew is unfamiliar with procedures for recovery of a person in the water and requires
additional equipment to accompany the installed davit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2022
Resolved
Flexible connections between cylinders and distribution piping of semi-portable or fixed carbon dioxide fire extinguishing systems and discharge hoses in semi-portable carbon dioxide fire extinguishing systems must be replaced or tested at a pressure of 6.9 MPa (1,000 psig). Dry rot was identified on the flex loop of the semi-portable system in the Fidley. Test to the required pressure or replace in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 June 2022
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. One of the steering stop assists is non-operational and allows for overextension of the ram.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 10 June 2022
Resolved
The vessel, including crew's quarters and the galley, must be kept in a sanitary condition. The vessel does not have a functioning head or accompanying sink. Re-install prior to overnight voyages.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 10 June 2022
Resolved
Each escape hatch and emergency exit used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. The escape hatch in the engine room does not have proper markings.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 November 2019
Resolved
Conduct hydro static test of air receivers in E/R in the presence of a CG Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2019
Resolved
Electrical equipment and electrical cables must be suitable protected from wet and corrosive environments. Install junction box for spliced wiring on flying bridge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2019
Resolved
Electrical equipment and electrical cables must be suitable protected from wet and corrosive environments. Renew wiring to port navigation light where sheathing had become wasted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2019
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Remove dead ended cabling in overhead of upper stateroom.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 November 2019
Resolved
Electrical conducters passing through watertight bulkheads must be installed so that the bulkhead remains water tight. 07 bulkhead penetrations in upper stateroom to be renewed or made water/fire tight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 November 2019
Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard or rail. Repair broken railing on upper engine room space aft by CO2 bottles.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 November 2019
Resolved
Sufficent lighting suitable for the marine environment must be provided within crew working areas. Renew broken light fixture globe on aft deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2018
Resolved
Install oversized washers of 1/2" steel plate to seal the bolt openings through the main deck where the winches are mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 3 May 2018
Resolved
Starboard side forward cleat shall either be removed or welded to the deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2018
Resolved
In the starboard deck locker (old CO2 space) an electrical cable is improperly spliced. The wiring connection shall be made inside of a junction box.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2018
Resolved
Renew all air receiver pressure relief valves with appropriate valves with a relif setting not to exceed 250 psig.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2018
Resolved
The opening in the DC electrical panel is not gaurded to prevent inadvertent access. Install a cover or guard over the opening.