MAURY USCG vessel records Sign in
← All vessels

FLORIDA HIGHWAY

FLORIDA HIGHWAY is a 2008 freight ship. The Coast Guard has recorded 17 inspections since 2008, most recently in January 2025, along with 7 deficiencies and 3 operational controls.

Records from 2008 to 2025. Most recent: inspection, 3 January 2025.

Built
2008
Last inspected
3 January 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9442861 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
947638
Flag
PANAMA
—
Maury page id
psix-947638

Inspections, by type

…with no type recorded5
Years with a record 12 calendar years (2008–2025)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it59493 - Convention (Subpart B), Gross Ton
34704 - Displacement, Gross Ton
19244 - Convention (Subpart B), Net Ton
18930 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

3 January 2025 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8051505
22 March 2024 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7883581
23 December 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7842091
26 December 2021 PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7370641
22 March 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6930100
16 November 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6849163
29 November 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6311885
12 May 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6145083
14 January 2016 Administrative Inspection · Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5791389
10 March 2014 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4812999
23 June 2012 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4352762
2 May 2012 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4298921
6 May 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3469243
22 December 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3383417
22 December 2008 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3383948
19 December 2008 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3382103
13 May 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3200639

Deficiency record · 7

Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Quantity of Foam-Forming Liquid
Issued 14 January 2016 Resolved
0725 - Fixed Fire Extinguishing Installation - The foam concentrates of high-expansion foam fire-extinguishing systems shall be approved by the Administration based on the guidelines developed by the organiziation. Vessel did not have a valid annual foam analysis test report. 74SOLAS(14) II-2/10.4.1.1.2, FSS CODE Ch.6.2.2.1.1 (MSC/Circ 670).
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 14 January 2016
Resolution: Vessel produced documentation of foam analysis report prior to PSCO departing vessel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 May 2012 Resolved
1730- Ships staff training should include familiarization in the operation and mainetance of the equipment. The Chief Engineer and engineering crew were unable to demonstrate competency in recalling alarm history and oil content meter data on the installed FOCAS-1800 system, as required by MEPC 107(49). MARPOL 2011 Cons. Annex I Reg 14, MEPC 107(49)
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2012
Resolved 4 May 2012
Resolution: Recieved class report attesting to competency and training of the vessel''''s engineering crew in ability to recall data on the oil content meter.
Lifesaving › Inflatable Liferafts › Painter
Issued 2 May 2012 Resolved
0630- Every liferaft shall be stowed with its painter permanently attached to the ship. Both the Port and Starboard liferafts did not have the sea painter connected to the ship. In the event of the vessel sinking, the hydrostatic release would allow the liferaft to float free, and the sea painter would not inflate the liferaft for its intended purpose. SOLAS 20O9 Cons. Chapter III Reg 13.4.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2012
Resolved 4 May 2012
Resolution: Received Class report attesting to proper functionality and installation of the vessel''s Port and Starboard liferafts.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 2 May 2012 Resolved
2565- Having regard to deficiencies 1,2,3, and 5, the Port State Control Officer has objective evidence to believe that a Major Non-Conformity exists with the implementation of the ISM Code. The vessel failed to follow the SMS developed by the company by failing to conduct drills and evaluations at the proper intervals, as well as being unfamiliar with essential shipboard equipment.
Action required: 705 - Other - as specified
Due 4 May 2012
Resolved 4 May 2012
Resolution: Received ISM audit from Nippon [name withheld] stating that deficiencies identified had been resolved and that an additional ISM audit was to be conducted on 02AUG12 and received flag state approval letter.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 2 May 2012 Resolved
2555-Drill & Excercise records could not be produced for SOPEP drills in June 2011, Feb 2012 or March 2012. Both SOPEP and Safety Management Manual require monthly drill and for form SHOEI-SM03-08 to be filed .SOLAS 2009 Cons. Chap IX Reg3
Action required: 705 - Other - as specified
Due 2 May 2012
Resolved 4 May 2012
Resolution: Received ISM audit from Nippon [name withheld] stating that deficiencies identified had been resolved and that an additional ISM audit was to be conducted on 02AUG12 and received flag state approval letter.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 2 May 2012 Resolved
2555- The Pollution Incident Form, SHOEI-SM-06-011, was not filed as required by the Safety Management Manul for 13 months in the last three years. SOLAS 2009 Cons. Chap IX Reg3
Action required: 705 - Other - as specified
Due 2 May 2012
Resolved 4 May 2012
Resolution: Received ISM audit from Nippon [name withheld] stating that deficiencies identified had been resolved and that an additional ISM audit was to be conducted on 02AUG12 and received flag state approval letter.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 2 May 2012 Resolved
2555- The vessel's Safety Management Manual requires the Master to complete Drill and Excercise Evaluation Records for all ISPS drills. No record could be found for any ISPS drill.SOLAS 2009 Cons. Chap IX Reg3
Action required: 705 - Other - as specified
Due 2 May 2012
Resolved 4 May 2012
Resolution: Received ISM audit from Nippon [name withheld] stating that deficiencies identified had been resolved and that an additional ISM audit was to be conducted on 02AUG12 and received flag state approval letter.

Ownership record