MAURY USCG vessel records Sign in
← All vessels

SKYROS

SKYROS is a 2006 tank ship. The Coast Guard has recorded 7 inspections since 2008, most recently in September 2017, along with 9 deficiencies and 2 operational controls.

Records from 2008 to 2017. Most recent: inspection, 27 September 2017.

Built
2006
Last inspected
27 September 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9327425 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
948759
Flag
GREECE
—
Maury page id
psix-948759

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2008–2017)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23270 - Convention (Subpart B), Gross Ton
9925 - Convention (Subpart B), Net Ton
36660 - Dead Weight, Metric Ton
45628 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 7

27 September 2017 Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6274440
28 March 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5832086
28 March 2016 COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5842291
27 March 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5841464
13 March 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5832358
23 March 2009 COE-Dockside
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3437817
19 May 2008 Ballast Water Examination · Deficiency Check · COC-TVE Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3211337

Deficiency record · 9

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 March 2016 Resolved
0715-Detection-Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed 02 smoke detectors fitted with coverings preventing them from operating as designed. SOLAS 74 (09) II-2/14.1 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2016
Resolved 1 April 2016
Resolution: Class report stated-Verified from records on board that all fire detectors on board were examined / verified by Electrician. ln addition, a complete examination and testing now held by the undersigned Surveyor and found in order. See narrative for details
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 March 2016 Resolved
0945-Emergency lighting, etc-Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed 05 emergency lights were not operational. SOLAS 74 (09) III/20 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2016
Resolved 1 April 2016
Resolution: Class report stated-The whole emergenry lighting system now tested and found in good working condition and clearly marked as per approved drawings.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 28 March 2016 Resolved
2550-maintenance of ship and equipment-The company should ensure that all personnel involved in the Company's safety management system have an adequate understanding of regulations, codes and guidelines. PSCO noted the electrician failed to test all smoke detectors in the engine room and had not ensured all emergency lighting on board was working properly. SOLAS (09) ISM Code A 6.4 50a
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 1 April 2016
Resolution: Class Report Stated As per item 01 above. lt was further verified that Electrician on board is now well familiarized with the fire / smoke detection system. lt was noted that Vessel is newly managed by ELECTSON CORPORATION.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 28 March 2016 Resolved
0699-Other-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship persons on board. PSCO observed cracks on two of the fuel hoses on the IGG. SOLAS (09) I/11 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 28 March 2016
Resolution: Corrected on the spot. Cheif Engineer replaced hoses with on-board spares.
Engineering › Steam System (auxiliary) › Valve
Issued 28 March 2016 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO observed an unattended fuel oil leak on the boiler top and steam leak coming from the main steam valve nearby. SOLAS (09) I/11 COB 4Apr16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 1 April 2016
Resolution: Class Report stated-F.O leaks from Boiler burner unit atomizer now repaired and found satisfactory. Spares hoses stated already ordered.
Fire Fighting › Combustible Materials › Insulation
Issued 28 March 2016 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects to proceed to sea without danger to ship or persons on board. PSCO observed wires that were exposed on the starboard winch controller for the embarkation ladder in the hazardous zone. Also flame screens. SOLAS (09) I/11 COB 4Apr16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 1 April 2016
Resolution: Class report stated- Exposed wire from starboard side ladder winch controller now renewed by spare on board and found satisfactory. All flame screens from ballast tank air pipes on deck verified by properly adjested covers.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 28 March 2016 Resolved
1899-Other(tankers)-Every ship to which this Annex applies shall be provided with a Cargo Record Book. The Crew was unable to provide a cargo record book. Master stated the vessel's flag changed and all documents were taken, company sending one this port of call. Also the International Certificate of Fitness for chemicals was dated incorrectly. (19 FEB 2019) MARPOL Annex II/15. 16a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 1 April 2016
Resolution: Class stated- Cargo Record Book now verified on board. lnternational Certificate of Fitness for the Carriage of Dangerous Chemicals in Bulk amended to 19Feb2016. Previous attending Surveyor contacted, stating that amended Certificate will be reissued.
Operations/Management › Log/Records › Ballast Water Logs/Records
Issued 20 May 2008 Resolved
2535 - Ballast Water Management - Vessel has two company provided plans which are not complete. Plan dtd 11NOV06 approved by Class is missing diagram for sampling points and capacity for AFPT conflicts with IOPP. Records for Training & Sediment not being maintained IAW the Plan. (70 a/b)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 17 June 2008
Resolution: Deficiency cleared based on receipt of ABS Class report HS1014739, dated 17 Jun 08.
Documentation › Certificates/Documents › Certificate of Fitness (BCH Code)
Issued 20 May 2008 Resolved
1900 - MARPOL A-II - Certificate of Fitness dated 14 June 07, is missing the Attachments for the list of products vessel is authorized to carry. (15 a/b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 17 June 2008
Resolution: Deficiency cleared based on receipt of ABS Class report HS1014739, dated 17 Jun 08.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.