MAURY USCG vessel records
← All vessels

HARVEY STORM

HARVEY STORM is a 2009 offshore supply vessel. The Coast Guard has recorded 18 inspections since 2017, most recently in July 2026, along with 11 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 13 July 2026.

Built
2009
Last inspected
13 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 July 2026
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9536234
949503
Flag
MEXICO
Maury page id
psix-949503

Documentation record

Tonnage as PSIX records it1596 - Convention (Subpart B), Gross Ton
2755 - Dead Weight, Gross Ton
1089 - Displacement, Gross Ton
587 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

13 July 2026 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8437427
6 February 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8307060
22 January 2026 PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8300074
16 October 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7809035
30 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7569386
19 July 2022 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7511025
11 April 2022 Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7430455
7 January 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412301
11 November 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7094111
5 June 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6968862
22 April 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6942320
28 February 2020 Appeal
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 6917533
2 October 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6826302
5 August 2019 Examination of Repairs · Initial Certification · Ballast Water Examination · MARPOL Annex IV Survey · COI Inspection · MARPOL Annex V Examination · Construction Oversight · MARPOL Annex II Examination · Administrative Inspection · Initial Construction-Excluding Oversight · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6773419
5 June 2019 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6704245
18 September 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6553554
14 June 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6175988
5 January 2017 DAPI Audit · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6068602

Deficiency record · 11

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 January 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. During the test of the rescue boat, the cord to the outboard engine broke and when replaced the engine would not turn over. 74 SOLAS 2009 III/20.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2026
Resolution: CONDUCTED SAT TEST OF RESCUE BOAT ENGINE
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 27 January 2026 Resolved
A daylight signaling, or other means, to communicate by light day and night using an energy source not soley dependent on ships power. Daylight signaling lamp did not have seperate source of power. 74 SOLAS 2009 V/19.2.2.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 5 February 2026
Resolution: VERIFIED SEPARATE SOURCE OF POWER
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 January 2026 Resolved
12 rocket parachute flares shall be carried/stowed on or near the nav bridge complying with the LSA Code. Flares not stowed in water resistant container. 74 SOLAS 2009 III/6.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 5 February 2026
Resolution: VERIFIED FLARES WERE STOWED IN WATER RESISTANT CONTAINER
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 October 2023 Resolved
Each Class 1 door must have a quick action closing device operative from both sides of the door. The quick action closing device on the port emergency escape hatch on the deck did not apply enough pressure on the knife-edge for the gasket to produce a water tight seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 19 October 2023
Resolution: Verified Hatch sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2022 Resolved
A procedure for tests to be conducted on automated equipment by the operator and the Coast Guard must be submitted to comply with 127.110. Vessel crew was unable to produce approved automation testing procedures.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 20 September 2023
Resolution: Stamped and Embossed current PSTPs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2022 Resolved
No repairs or alterations to machinery or equipment that affects the safety of the OSV, may be made without notice to the OCMI. The low lube oil pressure and jacket water temperature safety shutdowns on three generators were disabled.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2022
Resolved 29 August 2022
Resolution: Verified alarms were enabled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2022 Resolved
No repairs or alterations to machinery or equipment that affects the safety of the OSV, may be made without notice to the OCMI. The bus tie on the center generator has conflicting indications for open/close. The light on the panel shows circuit breaker open and the Woodward electronic display shows closed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2022
Resolved 29 August 2022
Resolution: Vessel proved to attending MI's that there was no issue with the vessels switchboard and its corresponding breakers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2022 Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valve located at the tank and must be arranged with means of manual local control and remote control from a safe location outside the compartment which the valves are located. Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 L and above shall be fitted with a valve on the tank capable of being closed from a safe position outside the space. The controls for remote operation of the valve for the emergency generator fuel tank shall be in a separate location from the controls for remote operation of other valves for tanks located in machinery spaces. It was noted that the emergency generator does not have a means to cut off the fuel supply at the tank and operable from outside the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2022
Resolved 29 July 2022
Resolution: Cleared by Sector Mobile on 29JUL2022.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 April 2022 Resolved
Potable water tank Port wasted/missing pipe hangers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 21 April 2022
Resolution: Repaired sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 11 November 2020 Resolved
Oil record book not signed by vessel master on page bottom
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2020
Resolved 12 November 2020
Resolution: Vessel crew resolved
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 November 2020 Resolved
Vessel personnel were not proficient at abandoned ship drill. Life boat davit could not be operated.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2020
Resolved 12 November 2020
Resolution: Vessel crew demonstrated proper drill

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.