Records from 2017 to 2026. Most recent: inspection, 13 July 2026.
Inspection history · 18
13 July 2026
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8437427
6 February 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8307060
22 January 2026
PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8300074
16 October 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7809035
30 September 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7569386
19 July 2022
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7511025
11 April 2022
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7430455
7 January 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7412301
11 November 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7094111
5 June 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6968862
22 April 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6942320
28 February 2020
Appeal
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 6917533
2 October 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6826302
5 August 2019
Examination of Repairs · Initial Certification · Ballast Water Examination · MARPOL Annex IV Survey · COI Inspection · MARPOL Annex V Examination · Construction Oversight · MARPOL Annex II Examination · Administrative Inspection · Initial Construction-Excluding Oversight · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6773419
5 June 2019
Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6704245
18 September 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6553554
14 June 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6175988
5 January 2017
DAPI Audit · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6068602
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 January 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. During the test of the rescue boat, the cord to the outboard engine broke and when replaced the engine would not turn over.
74 SOLAS 2009 III/20.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2026
Resolution: CONDUCTED SAT TEST OF RESCUE BOAT ENGINE
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 27 January 2026
Resolved
A daylight signaling, or other means, to communicate by light day and night using an energy source not soley dependent on ships power. Daylight signaling lamp did not have seperate source of power.
74 SOLAS 2009 V/19.2.2.2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 5 February 2026
Resolution: VERIFIED SEPARATE SOURCE OF POWER
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 January 2026
Resolved
12 rocket parachute flares shall be carried/stowed on or near the nav bridge complying with the LSA Code. Flares not stowed in water resistant container.
74 SOLAS 2009 III/6.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2026
Resolved 5 February 2026
Resolution: VERIFIED FLARES WERE STOWED IN WATER RESISTANT CONTAINER
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 October 2023
Resolved
Each Class 1 door must have a quick action closing device operative from both sides of the door. The quick action closing device on the port emergency escape hatch on the deck did not apply enough pressure on the knife-edge for the gasket to produce a water tight seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2023
Resolved 19 October 2023
Resolution: Verified Hatch sealed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2022
Resolved
A procedure for tests to be conducted on automated equipment by the operator and the Coast Guard must be submitted to comply with 127.110. Vessel crew was unable to produce approved automation testing procedures.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2022
Resolved 20 September 2023
Resolution: Stamped and Embossed current PSTPs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2022
Resolved
No repairs or alterations to machinery or equipment that affects the safety of the OSV, may be made without notice to the OCMI. The low lube oil pressure and jacket water temperature safety shutdowns on three generators were disabled.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 July 2022
Resolved 29 August 2022
Resolution: Verified alarms were enabled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2022
Resolved
No repairs or alterations to machinery or equipment that affects the safety of the OSV, may be made without notice to the OCMI. The bus tie on the center generator has conflicting indications for open/close. The light on the panel shows circuit breaker open and the Woodward
electronic display shows closed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2022
Resolved 29 August 2022
Resolution: Vessel proved to attending MI's that there was no issue with the vessels switchboard and its corresponding breakers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 July 2022
Resolved
Piping subject to internal head pressure from oil in the tank must be fitted with positive shutoff valve located at the tank and must be arranged with means of manual local control and remote control from a safe location outside the compartment which the valves are located.
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 L and above shall be fitted with a valve on the tank capable of being closed from a safe position outside the space. The controls for remote operation of the valve for the emergency generator fuel tank shall be in a separate location from the controls for remote operation of other valves for tanks located in machinery spaces. It was noted that the emergency generator does not have a means to cut off the fuel supply at the tank and operable from outside the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2022
Resolved 29 July 2022
Resolution: Cleared by Sector Mobile on 29JUL2022.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 11 April 2022
Resolved
Potable water tank Port wasted/missing pipe hangers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 21 April 2022
Resolution: Repaired sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 11 November 2020
Resolved
Oil record book not signed by vessel master on page bottom
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2020
Resolved 12 November 2020
Resolution: Vessel crew resolved
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 November 2020
Resolved
Vessel personnel were not proficient at abandoned ship drill. Life boat davit could not be operated.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2020
Resolved 12 November 2020
Resolution: Vessel crew demonstrated proper drill