QUO VADIS is a 1962 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in May 2026, along with 46 deficiencies and 1 casualty investigation in 2023.

Records from 2016 to 2026. Most recent: inspection, 13 May 2026.

Built
1962
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDK9555
Flag
UNITED STATES
Maury page id
psix-94990

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2016–2026)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)48.5 ft × 15.8 ft × 3.9 ft
Registered tonnagegross 20 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINETTE MARINE CORP · MARINETTE, WI, UNITED STATES · built 1962
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFISH CREEK, WI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 14

13 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8372774
8 May 2025 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8131328
23 May 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7918052
3 July 2023 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7734545
18 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7691385
19 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7455239
29 October 2021 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7341839
18 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7199976
10 May 2020 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6950976
6 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6705947
4 June 2018 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6437248
30 May 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6162820
15 March 2017 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6131760
23 May 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5884063

Deficiency record · 46

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 May 2026 Resolved
Aspirin on board was expired. Owner retrieved new aspirin before end of inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 May 2026
Resolved 13 May 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 May 2025 Resolved
Hatch gasket to steering gear space is no longer watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 24 May 2025
Resolution: Operator sent photographs of newly installed gasket material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2025 Resolved
Grab line on aft life ring buoy was wasted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 24 May 2025
Resolution: Operator sent photograph of new RLB, properly labeled and mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 May 2025 Resolved
Aspririn within first aid kit was expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 20 May 2025
Resolution: Received photo and receipt from operator of newly purchased aspirin.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 May 2025 Resolved
Lifejacket stowage was not marked with number of PFDs per stowage area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 24 May 2025
Resolution: Operator sent photographs of each pfd stowage bag with new labels indicated size and quantity of pfds inside.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2024 Resolved
Deteriorated SOLAS retro-reflective tape on 04 lifejackets. Rectify deficiencies within 30 days and prior to the carriage of more than 67 total persons on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 29 May 2024
Resolution: Received email with photographs of new SOLAS tape on pfds.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2024 Resolved
No high level bilge alarm in midship void space.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 7 June 2024
Resolution: Received videos and photographs of newly installed bilge alarm.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2024 Resolved
Multiple dead end wires in battery void space and behind operating station. Old T: 185.05-50(b)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 29 May 2024
Resolution: Received email from operator with photographs of identified dead end wires secured.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 May 2022 Resolved
Life saving equipment inspection and maintenance must be completed and properly logged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 21 May 2022
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 19 May 2022 Resolved
Provide proof that your consortium has all of your crew members as a part of their random pool.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: received documents from owner showing all crew enrolled in Bellin Health's random selection pool.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 May 2022 Resolved
Vessel must have on board navigation charts for the area of operation that are current to the last notice to mariners. This is an ongoing issue with this boat. Charts shall be maintained throughout the year and corrections must be logged and noted on the chart with the date of each notice to mariners.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 21 May 2022
Resolution: new chart was purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2022 Resolved
Batteries in the life ring and life float lights must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 21 May 2022
Resolution: New batteries were purchased and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 May 2022 Resolved
The vessel name and capacity of persons must be marked on the life float as per 185.604. The current labeling has faded away.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 20 May 2022
Resolution: Photos provided that show the life float properly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 May 2022 Resolved
The vessel name must be marked on all life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 21 May 2022
Resolution: 4 Child life jackets were found without vessel name. They have been labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 May 2022 Resolved
The life float paddles are deteriorated and one handle is broken. They are also not labeled with the vessel name as required. Paddles must meet 180.175. Replace the paddles with proper type and label them.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 21 May 2022
Resolution: Paddles have been replaced and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022 Resolved
The vessels primary life ring fitted with the required life line and light was faded, cracked and no longer serviceable. This was corrected on the spot with an extra life ring kept on board.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 19 May 2022
Resolution: Replacement was provided on the spot and properly outfitted.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 19 May 2022 Resolved
The wiring to the port and stbd nav lights are not watertight as required. Reinstall or renew the wiring to achieve water tightness.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: Photos provided showing cables pushed into the stuffing tubes and sealed with silicone.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2022 Resolved
The navigation light screens have faded to white. These must painted matte black.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 20 May 2022
Resolution: Photos provided of each screen freshly painted black.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 May 2022 Resolved
Properly secure the engine room bilge alarm to prevent damage from vibration and ship movement.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 20 May 2022
Resolution: Received video showing completion and proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 May 2022 Resolved
Replace the retro reflective tape on the life float as the current retro is no longer effective.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 19 May 2022
Resolution: New retro applied prior to inspection being completed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2022 Resolved
The alcohol test strips are exp. Provide means to test for alcohol within 2 hours.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 21 May 2022
Resolution: Alcohol strips were renewed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 May 2022 Resolved
Fire hose failed during inspection. Replace fire hose.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 June 2022
Resolved 19 May 2022
Resolution: A new fire hose was placed on board and tested, sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 May 2021 Resolved
Each vessel on a Great Lakes route is required to carry six (6) red hand flares and six (6) orange smoke flares. Several of the flares will be expiring this month (05/2021) and need to be replaced as necessary. 46 CFR 180.68
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2021
Resolved 27 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 May 2021 Resolved
Vessel are required to carry a first aid kit conplying with 46 CFR 160.041. FIrst aid kit has expired contents; replace as necessary. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 27 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021 Resolved
Each ring life buoy is required to have Type II reflective tape around the body. Aft life ring has deteriorated retro tape; replace as required. 46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2021
Resolved 27 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 May 2021 Resolved
Each survival craft onboard must be maintained in accordance with the manufacturer instructions. Life float netting is becoming deteriorated; contact manufacturer for performance requirements or replacement procedures for netting. Given a year to research and provide documentation/correspondence with local MIs. 46 CFR 185.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2022
Resolved 12 May 2022
Resolution: LF inspected and deemed acceptable.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 May 2020 Resolved
6 orange flares are expired. Procure 3 additional red or orange flares for a total of 12 unexpired flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2020 Resolved
Prove proper operation of propulsion main diesel engines
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2019 Resolved
Life jackets must be stored in a convenient place throughout accomodation spaces. 13 lifejackets are currently stowed below deck and not accessible.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 24 June 2019
Documentation › Certificates/Documents › Stability Letter
Issued 4 June 2018 Resolved
Vessel has the wrong stability letter posted. Post proper stability letter.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2018
Resolved 20 June 2018
Resolution: Posted.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 4 June 2018 Resolved
Vessel/company has not submitted annual drug testing results (MIS reports) to the CG for 2016 and 2017. MIS reports are to be submitted each year by 15 March. Submit all missing MIS reports to CG.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2018
Resolved 20 June 2018
Resolution: Submitted and retained on board.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 4 June 2018 Resolved
Employee Assistance Program information must be posted and available to employees. Post contact information for EAP resources.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2018
Resolved 20 June 2018
Resolution: Posted.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 June 2018 Resolved
Company does not have a sufficiently detailed drug testing program to encompass all required components IAW regulations. Establish/document a proper drug testing program/policy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2018
Resolved 20 June 2018
Resolution: Program updated.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 4 June 2018 Resolved
The stbd main engine oil pressure gauge does not function as designed. Provide a properly functioning oil pressure gauge.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2018
Resolved 20 June 2018
Resolution: Installed new gauge.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 4 June 2018 Resolved
The port and stbd exhaust pipes have cracked welds at the bulkhead in the muffler void space causing exhaust gases to enter the space. Make permanent repairs and prove proper operation of exhaust system.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2018
Resolved 20 June 2018
Resolution: Small pinhole plugged with sealant. To address again this winterlayup if issue recures.
Engineering › Bilge Water Management System › Interface Detector
Issued 4 June 2018 Resolved
The steering gear void's bilge pump float switch is cracked. Replace float switch and demonstrate proper operation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2018
Resolved 20 June 2018
Resolution: Corrected and functional.
Lifesaving › Buoyant Apparatus › Painter
Issued 30 May 2017 Resolved
The Life float did not have a painter line as required. Install min of 100' of approved painter line.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2017
Resolution: 100' of appropriate painter line was installed and verified.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 30 May 2017 Resolved
The life float does not have two 4' paddles as required. Lash two paddles to the life float as required.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2017
Resolution: paddles were installed and verified.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 30 May 2017 Resolved
The life float does not have a weak link as required. Install proper weaklink.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2017
Resolution: Weaklink was installed as required.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 30 May 2017 Resolved
Water light does not have proper length of line attached to LF. Replace with 18' of approved line as required.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2017
Resolution: proper line was installed and verified.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 May 2017 Resolved
first aid kit was found with exp contents. replace with current and approved kit.
Condition: Improper/Lack of Maintenance
Due 8 June 2017
Resolved 7 June 2017
Resolution: new first aid kit was placed on board with current contents.
Engineering › Fuel Oil Service System › Piping
Issued 30 May 2017 Resolved
Fuel piping on the stbd engine has a kink and damage to the copper fuel line. Renew section of bad piping.
Condition: Improper/Lack of Maintenance
Due 8 June 2017
Resolved 7 June 2017
Resolution: Verified that the bad section of piping was removed. All sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 May 2017 Resolved
Three PFDs were removed and destroyed due to poor condition of Kapoc. Place 3 new TYPE I pfds on board as replacements and properly label them with the vessel name. vessel limited to no more than 69 total POB until PFDs are replaced.
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 6 June 2017
Resolution: verified via pictures and reciept that new PFDs have been placed on board.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 30 May 2017 Resolved
on board posted emergency instructions did not contain all required content. Add heavy weather instructions and post at operating station.
Condition: Improper Installation
Due 6 June 2017
Resolved 6 June 2017
Resolution: Proper instructions were posted at operating station.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 30 May 2017 Resolved
Vessel does not properly notify employees of selection for random testing. It appears as though the company gives the employees advance notice of testing and allows them to go at thier convienance within a 30 day window due to company misunderstanding of testing requirments. Provide proof of adequate testing program and proper implimentation.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 23 June 2017
Resolution: Information was provided and training/guidence was provided to program administrator to ensure full compliance.
Lifesaving › Hand Flares › Quantity
Issued 23 May 2016 Resolved
Vessel fitted with four red & three orange flares. Fit vessel with 6 red & 6 orange distress signals, approved under, red flares 160.021 and orange flares 160.037, per 46 CFR 180.68(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 23 May 2016
Resolution: Prior to departing, O/O provided four new Red & four new orange flares approved under 160.021 & 160.037

Casualty record · 1

3 July 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7734545
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.