AFRICAN QUEEN is a 2007 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in March 2026, along with 5 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 16 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it30936 - Convention (Subpart B), Gross Ton 18150 - Convention (Subpart B), Net Ton 55005 - Dead Weight, Ton 64449 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
9 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
16 March 2026PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8326789
21 November 2022Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7598027
22 January 2022PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7383959
21 January 2022Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7384487
18 March 2020Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6928335
5 March 2020PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6921199
6 April 2018ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6377854
29 March 2018Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6381013
25 October 2016ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6023814
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations.
40c
33 CFR 151.2025(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 March 2026
Resolution: Sector San Francisco conducted a PSC B exam, ballast water managment system was found to be fully operational. No issues pertaining to BWMS was reported by vessel or company. In addition, a flag inspector was on board, flag exam reported no BWMS findings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 January 2022Resolved
13101 - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. THE VESSEL LOST PROPULSION FOR APPROXIMATELY 5 MINUTES WHILE ENROUTE TO THE PORT OF BALTIMORE.
74SOLAS(20)I/II(A)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 February 2022
Resolved 27 January 2022
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 January 2022Resolved
07113 - FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED LEAKS ON THE FIREMAIN PIPELINE ADJACENT TO CARGO HOLDS #1, #2, AND #5. ADDITIONALLY THE CREW WAS UNABLE TO GET PRESURE AT THE FIRE STATION ON FORECASTLE.
74SOLAS(20) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 February 2022
Resolved 27 January 2022
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 January 2022Resolved
07124 - ANNUAL INSPECTIONS SHOULD BE CARRIED OUT ON FIXED GAS FIRE EXTINGUISHING SYSTEMS. THE FIXED C02 SYSTEM WAS LAST INSPECTED ON 5/11/2020. ADDITIONAL RECORDS SHOW THE SYSTEM WAS TESTED BETWEEN JANUARY AND DECEMBER 2021 WITH NO SPECIFIED DATE.
74SOLAS(20)I/II(A)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2022
Resolved 27 January 2022
Resolution: Received class report attesting to repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2022Resolved
99101 - EACH TRANSFER PIPE SYSTEM MUST NOT LEAK UNDER STATIC LIQUID PRESSURE AT LEAST 1 1/2 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE. THE BUNKER LINES WERE TESTED PNEUMATICALLY.
33CFR156.170
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 February 2022
Resolved 27 January 2022
Resolution: Received class report attesting to repairs.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National