MAURY USCG vessel records
← All vessels

PACIFIC PROSPERITY

PACIFIC PROSPERITY is a 2008 tank ship. The Coast Guard has recorded 17 inspections since 2016, most recently in February 2026, along with 5 deficiencies and 4 operational controls.

Records from 2016 to 2026. Most recent: inspection, 24 February 2026.

Built
2008
Last inspected
24 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 February 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9326926
951218
Flag
LIBERIA
Maury page id
psix-951218

Documentation record

Tonnage as PSIX records it26751 - Convention (Subpart B), Gross Ton
14147 - Convention (Subpart B), Net Ton
57335 - Displacement, Ton
46190 - Dead Weight, Ton
26751 - Regulatory (Subpart C or D), Gross Ton
14147 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

24 February 2026 COC-CHEM Renew · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8314855
5 December 2024 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8040639
27 July 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7968008
10 July 2024 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7954895
16 June 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7935755
19 October 2023 COC-CHEM & TVE Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7811076
4 April 2022 COC-CHEM Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7420890
11 September 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7309849
9 March 2021 COC-CHEM & TVE Annual · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7151309
25 February 2020 Deficiency Check · PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6910766
23 July 2019 ISPS II Exam · COE-Administrative
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6758553
26 August 2018 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6519878
11 June 2017 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6173170
9 June 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6170688
18 April 2017 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6120113
6 March 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5827948
19 February 2016 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5818266

Deficiency record · 5

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 5 December 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed emergency generator unable to start with primary battery. Additionally after starting hydraulically, crew was not able to stop the emergency generator via switchboard. While attempting to stop, sparks emitted from the engine. 74 SOLAS (20) I/11a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 December 2024
Resolution: Received class report attesting to proper operation of EGEN.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 December 2024 Resolved
Vapor piping, fitting, valves, flanges, and pressure vessels comprising the construction and installation of a permanent or portable vapor processing unit onboard a tank vessel must meet the marine engineering requirements of 46 CFR chapter 1, subchapter F. PSCO observed port FWD vapor line connection at manifold leaking. Crew tightened flange, no further leak. 46 CFR 39.1009(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 5 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2024 Resolved
The speed, direction of thrust... shall be fully controllable from the navigation bridge under all sailing conditions, including manuevering. Main engine was unable to go astern from the bridge when requested during mooring evolution.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2024
Resolution: Class Report Provided
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 March 2021 Resolved
Every rescue boat shall be capable of manuvering at a speed of at least 6 knots. PSCO observed that the rescue boat engine was unable to increase RPM and operate at required speed. Company was notified on 20JAN2021. Plan for repair has not been finalized.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 February 2020 Resolved
Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. PSCO found the CO2 system bottle for the main deisel engine fixed fire-fighting system has not been tested in the past 3 years. SOLAS (2014) II-2/ Reg 14.1.2
Action required: 17 - Rectify deficiencies prior to departure
Due 25 February 2020
Resolved 28 February 2020
Resolution: Received technician report for the testing of the CO2 Canister.