← All vessels
HOLSTEIN EXPRESS
Freight Ship · General Dry Cargo Ship class · Built 1990s · USCG East District (CGD-E) · Other hulls named HOLSTEIN EXPRESS
HOLSTEIN EXPRESS is a 1991 freight ship. The Coast Guard has recorded 16 inspections since 2008, most recently in March 2021, along with 32 deficiencies and 5 operational controls.
Records from 2008 to 2021. Most recent: inspection, 1 March 2021.
- Built
- 1991
- Last inspected
- 1 March 2021
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 32 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9004413 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LXHT
951571
Flag
LUXEMBOURG
—
Maury page id
psix-951571
Inspections, by type
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it7896 - Convention (Subpart B), Gross Ton
3329 - Convention (Subpart B), Net Ton
3905 - Dead Weight, Ton
3329 - Convention (Subpart B), Net Ton
3905 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
1 March 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7148072
10 February 2021
PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7138463
18 February 2020
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6910428
8 December 2019
Deficiency Check · ISPS III Exam · Administrative Inspection · NPV Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6869855
7 December 2019
PI Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6867117
3 December 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6866102
25 August 2014
PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4964798
21 August 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4961931
6 June 2012
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4334652
6 June 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4335567
3 June 2012
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4332903
2 December 2009
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3643229
22 July 2009
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3542277
2 December 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3372685
27 June 2008
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3249968
30 May 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3222317
Deficiency record · 32
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 February 2021
Resolved
NOTICED ALL THE SMOKE DETECTORS AND HEAT DETECTORS IN THE ENGINE ROOM AND ENGINE CONTROL ROOM WERE NOT WORKING. NOTICED 02 SMOKE DETECTORS IN THE CARGO HOLD GENERATOR SPACE WERE PURPOSELY COVERED.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 February 2021
Resolved
LIFERAFT WAS FOUND UNSECURED TO THE BRACKET DUE TO A MISSING PIN IN THE U-BOLT SHACKLE.
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 10 February 2021
Resolved
PSCE OBSERVED HOSPITAL ACCOMODATIONS BEING USED BY CREWMEMBER FOR BERTHING PURPOSES, NOT A MEDICAL PURPOSE.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 10 February 2021
Resolved
VESSEL FAILED TO USE COMPANY'S INSTRUCTIONS TO PERFORM MAINTENANCE ON FIRE DETECTION SYSTEM, WHICH WERE UNCLEAR, CAUSING FAILURE TO THE SMOKE AND HEAT DETECTORS IN ENGINE CONTROL ROOM AND ENGINE ROOM.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 February 2020
Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects with remin fit to proceed to sea. Cargo generator room had excessive fuel oil accumulation between the fuel oil service tank and the bulkhead.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 February 2020
Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers...Hatch covers shall be weathertight. Team found a hose passing through 2 weathertight doors preventing proper closure.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2019
Resolved
Openings in freeboard decks other than hatchways, machinery space openings, manholes and flush scuttles shall be protected by an enclosed superstructure, or by a deckhouse or companionway of equivalent strength and weather-tightness. The deck above engine room starboard side entrance was leaking standing water into engine room via an unused cable penetration opening. ICLL Annex I protocol 1988 ch. 2/Reg. 18.2 - 16ac
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 December 2019
Resolved
Steering gear compartments shall be provided with handrails and gratings or other non-slip surfaces. Vessel's deck surrounding steering gear does not have non-slip protection for crew. 74SOLAS(2004)II-I/29.13.2 - 50ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 December 2019
Resolved
The condition of the ship and it's equipment shall be maintained to ensure it remains fit for sea. The Coast Guard received a report that the vessel lost the ability to go astern while mooring at the Port of Wilmington. 74SOLAS(2014) I/11 - 60ac
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 7 December 2019
Resolved
vESSELS 40OGT AND OVER SHALL BE FITTED WITH OIL FILTERING EQUIPMENT ENSURING OILY MIXTURES GREATER THAN 15PPM ARE NOT DISCHARGED INTO SEA. PROPER OPERATION OF OILY WATER SEPERATOR COULD NOT BE DEMONSTRATED TO PSCO.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 7 December 2019
Resolved
OIL FILTERING EQUIPMENT SHALL ENSURE OILY MIXTURES DISCHARGED DO NOT EXCEED 15PPM. BILGE ALARM SHOULD RECORD AND STORE DATA FOR AT LEAST 18 MONTHS. PSCO WAS UNABLE TO VERIFY LOG OF OPERATIONS.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 December 2019
Resolved
A' CLASS BOUNDRIES BETWEEN MACHINERY SPACES OF CATEGORY A AND CONTROL STATIONS SHALL BE SUITABLY INSULATED. PSCO FOUND INSULATION MISSING BEHIND SWITCHBOARD IN ENGINE CONTROL ROOM. ADDITIONALLY PSCO FOUND INSULATION MISSING ON BOUNDRY BETWEEN STEERING GEAR ROOM AND ENGINE ROOM.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 7 December 2019
Resolved
SPURLING PIPES AND CABLE LOCKERS SHALL BE WATERTIGHT UP TO THE DECK EXPOSED TO WEATHER. BOSUN STORE IS FLOODED. SPURLING PIPE COVER IS MISSING.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 7 December 2019
Resolved
TANKS THAT HOLD OILY BILGE WATER ARE TO BE LISTED ON IOPP. ON 01DEC2019 2 CUBIC METERS OF BILGE WATER WAS TRANSFERED TO 02 1 CUBIC METER PORTABLE IBC TANKS LOCATED OUTSIDE OF THE ENGINE ROOM. THESE TANKS ARE NOT LISTED ON THE IOPP AS AN APPROVED HOLDING TANK.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 December 2019
Resolved
A' CLASS BOUNDRIES SHALL BE SO CONSTRUCTED AS TO BE CAPABLE OF PREVENTING THE PASSAGE OF SMOKE AND FLAME FOR 1 HOUR. 'A' CLASS BOUNDRY BETWEEN STEERING GEAR ROOM AND ENGINE ROOM CONTAINING 02 OPEN PENATRATIONS; OPEN CABLE WAY, AN OPEN CUT PIPE PENATRATION.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Winches & capstans
Issued 7 December 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO ENSURE IT REMAINS FIT FOR SEA. VESSEL EXPERIENCED SIGNIFICANT DOWNFLOODING INTO THE BOSUN STORE DURING VOYAGE. BOSUN STORE IS CURRENTLY FLOODED POTENTIALLY RENDERING THE HYDRAULIC SYSTEM FOR THE MOORING WINCH AND ANCHOR WINDLASS INOPERABLE. VESSEL IS UNABLE TO VERIFY PROPER OPERATION OF AFOREMENTIONED EQUIPMENT.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 7 December 2019
Resolved
CONTAINMENT OF LEAKAGES SHALL BE PROVIDED FOR MACHINERY SPACE AND SHALL BE FITTED WITH ADEQUATE DRAINAGE. ENGINE ROOM BILGE WELL HIGH LEVEL. ALARM IS ACTIVE DUE TO HIGH LEVEL OF BILGE WATER AND OIL.
SOLAS 74 (92 CONS) II-2/3.20 MSC CIRC 601
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 December 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO ENSURE IT REMAINS FIT FOR SEA; NO CHANGE SHALL BE MADE WITHOUT APPROVAL. CEMENT PATCH AT ENGINE ROOM TANK TOP AT FUEL OIL TANK 1C.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 December 2019
Resolved
LIFEBOATS SHALL BE STOWED AND EQUIPPED AS REQUIRED BY THE CODE. PORT SIDE LIFEBOAT'S PORTABLE FIRE EXSTINGUISHER HAD INADEQUATE PRESSURE AS INDICATED BY THE GAUGE BEING IN THE RED.
Engineering › Steering Gear System › Piping
Issued 25 August 2014
Resolved
0936- Steering Gear System - A hydraulic power-operated steering gear shall be provided with a fixed storage tank having sufficient capacity to recharge at least one power acutating system including reservoir. The vessel's steering gear is not provided with a fixed storage tank - 74 SOLAS (01 Con) II-1/29.12.3 (50ac)
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 25 August 2014
Resolved
0710- Fuel Oil Storage and Transfer System- Means shall be provided to control leaks of flammable liquids. Port State Control officers found fuel oil leaking from the bunker line on the port side - 74 SOLAS (09 Con) II-2/4.1 (50ac).
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 25 August 2014
Resolved
1571- Steering Gear- The angular position of the rudder angle indicator shall be indicated on the navigation bridge. The rudder angle indicator located on the bridge will not move past 30 degrees to starboard when the rudder is at 35 degrees starboard- 74 SOLAS (01 Con) II01/29.11.1 (50ac)
Construction/Loadline › Penetrations › Gasket
Issued 25 August 2014
Resolved
1270- Doors- All access openings in bulheads at ends of enclosed superstructures shall be weathertight. The following doors could not be closed to ensure they are weathertihgt: both port and startboard doors on the bridge and the port side door on the #6 deck- ICLL Ch. II/Reg 12 (16ac).
Lifesaving › Launching Appliances › Davit
Issued 25 August 2014
Resolved
0613- Stowage of Lifeboats- Where the davit arms are recovered by power, safety devices shall be fitted which will automatically cut off the power. The safety devices on the starboard and port lifeboat davits do not cut off the power- 74 SOLAS (97 Con) III/48.2.5 (16ac).
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 6 June 2012
Resolved
1240- The means for securing and maintaining weathertightness shall ensure that the tightness can be maintained in any sea conditions. The elevator weathertight hatch is not capable of closing due to the elevator frame permanently attached through hatch opening. ILLC 66 (05 ed) Reg. 16.4 Rectify prior to departure.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 30 May 2008
Resolved
The vessel has not prepared or submitted a non-tank vessel response plan to the USCG IAW the U.S. Federal Water Pollution Control Act as amended by Section 701 and the Coast Guard Maritime Transportation act of 2004. There is no due date issued for this deficiency. 33USC1321(j)(5)
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2008
Resolved
Vessel does not have nautical chart 1368 (Oahu-Honolulu Harbor) on board. 33 CFR 164.33(a)(1)(i) Rectify prior to next U.S. port after sailing foreign.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 30 May 2008
Resolved
Alarm panel on bridge (including steering gear alarms) is labeled in Japanese. This is not the working language of the ship or crew. SOLAS 74 Ch. II-1 Reg 29.8.4 Rectify prior to next U.S. after sailing foreign.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 30 May 2008
Resolved
The vessel does not have a maneuvering fact sheet on board. Rectify prior to next U.S. port after sailing foreign.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 May 2008
Resolved
The bracket for the fire extinguisher in the galley does not fit the ext. Ext is being held to the bracket by a bungee cord. Rectify prior to U.S. after sailing foreign.
Fire Fighting › Fire Main › Condition
Issued 30 May 2008
Resolved
The fire main piping in the Bosun store has two temporary patches on the line. Rectify prior to next U.S. after sailing foreign. Accidentally put code c on form b and needs to be to the sat of class. Notified vessel via phone.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 May 2008
Resolved
The deck railing above the main deck is broken in four places on the starboard side. Rectify prior to next U.S. after sailing foreign.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.