Records from 1993 to 2011. Most recent: inspection, 21 April 2011.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)41.3 ft × 19.9 ft × 5.0 ft
Registered tonnagegross 41 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSABINE NECHES SHIPBUILD · PORT ARTHUR, TX, UNITED STATES · built 1967
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Net Ton
41 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
11 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; 1 vessel inspected with it, by name and date; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 11
21 April 2011
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4020517
10 January 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3924209
26 October 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3087592
12 June 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2959644
6 April 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2903118
8 November 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1766295
2 November 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 284175
4 December 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 33704
2 June 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 644214
20 May 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 358477
18 May 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 457064
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 January 2011
Resolved
emergency fuel shut-off inoperable
Action required: 705 - Other - as specified
Resolved 21 May 2011
Resolution: Resolved
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 10 January 2011
Resolved
No portable fire extinguishers on board
Action required: 705 - Other - as specified
Resolved 21 April 2011
Resolution: Resolved
Documentation › Certificates/Documents › FCC SSL
Issued 10 January 2011
Resolved
Expired
Action required: 705 - Other - as specified
Resolved 21 March 2011
Resolution: Resolved
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 10 January 2011
Resolved
No sign of heat/flame/smoke detectors in engine room
Action required: 705 - Other - as specified
Resolved 21 April 2011
Resolution: Resolved
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 April 2007
Resolved
Stern light and towing light are inoperable.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 12 June 2007
Resolution: operative.
Fire Fighting › Fire Pumps › Arrangement
Issued 6 April 2007
Resolved
No fixed fire pump or portable fire pump is installed.
Action required: 705 - Other - as specified
Resolved 20 April 2007
Resolution: Self priming portable fire pump is onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 April 2007
Resolved
Fire extinguishers onboard are not in brackets.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 12 June 2007
Resolution: All extinguishers are in brackets.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 6 April 2007
Resolved
One B-V semi-portable extinguisher or fixed fire fighting system must be installed to protect engine room.
Action required: 705 - Other - as specified
Resolved 12 June 2007
Resolution: B-V semi-portable extinguisher onboard for protection of engine room.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 6 April 2007
Resolved
Life jackets must have lights attached.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 12 June 2007
Resolution: Lights are attached.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 6 April 2007
Resolved
Light list and tide/current tables must be onboard.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 12 June 2007
Resolution: Current edition of light list and tide/currents are onboard.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 April 2007
Resolved
No lagging or guards are on engine room exhaust or exhaust piping on aft main deck and navigational bridge deck.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 12 June 2007
Resolution: Lagging and guards have been placed on exhaust piping.
Construction/Loadline › Structures › End Bulkhead
Issued 6 April 2007
Resolved
Hull wastage to engine room access is excessive and allows water intrusion into a designated watertight space. Repair as original.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 12 June 2007
Resolution: Hull has been repaired.
Construction/Loadline › Structures › Door
Issued 6 April 2007
Resolved
Replace as necessary gaskets and dogs on watertight doors to engine room and galley.
Action required: 705 - Other - as specified
Due 4 May 2007
Resolved 12 June 2007
Resolution: New gaskets are on all watertight doors and dogs have been replaced as needed.
Construction/Loadline › Structures › Superstructure
Issued 6 April 2007
Resolved
Portal on aft superstructure main deck needs to be installed.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 12 June 2007
Resolution: Portal installed.
Engineering › Generator (propulsion-electric) › Battery
Issued 6 April 2007
Resolved
Ensure battery installation in engine room has a cover to prevent personnel injury.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 12 June 2007
Resolution: Batteries are in battery box.
Accommodation/Occupational Safety
Issued 2 November 2000
Resolved
NON-OPERABLE MSD. 33 CFR 159.65
Condition: Unknown
Due 11 November 2000
Resolved 16 November 2000
Fire Fighting
Issued 2 November 2000
Resolved
PORTABLE FIRE EXTINGUSHERS OUT OF TEST DATE. NFPA 10/ 49 CFR 173.304(a)
Condition: Unknown
Due 11 November 2000
Resolved 16 November 2000
Navigation
Issued 2 November 2000
Resolved
VESSEL MISSING USCG LIGHT LIST AND CURRENT LOCAL NOTICE TO MARINERS. 33 CFR164.72
Condition: Unknown
Due 11 November 2000
Resolved 16 November 2000
Navigation
Issued 2 November 2000
Resolved
COMPASS LIGHT NOT WORKING. 33 CFR 164.72.
Condition: Unknown
Due 11 November 2000
Resolved 16 November 2000
Navigation
Issued 2 November 2000
Resolved
VESSEL WAS USING HOUSEHOLD BULBS FOR NAV LIGHTS. UL 1104/COLREGS.
Condition: Unknown
Due 11 November 2000
Resolved 16 November 2000
Documentation
Issued 2 November 2000
Resolved
MISSING DISCHARGE WARNING PLACARD. 33 CFR 155.450
Condition: Unknown
Due 11 November 2000
Resolved 16 November 2000
Documentation
Issued 2 November 2000
Resolved
VESSEL SUBMITTED VERIFICATION OF PROGRAM AND POSTED ABOARD. 46 CFR16.40(a)
Condition: Unknown
Due 11 November 2000
Resolved 15 November 2000
Documentation
Issued 2 November 2000
Resolved
MISSING DRUG TESTING PROGRAM. NOT POSTED ON BOARD. 46 CFR 16.205
Condition: Unknown
Due 11 November 2000
Resolved 15 November 2000
Lifesaving
Issued 2 November 2000
Resolved
LIFE RINGS NOT SERVICEABLE. 46 CFR 25.25.5
Condition: Unknown
Due 11 November 2000
Resolved 16 November 2000
Accommodation/Occupational Safety
Issued 2 November 2000
Resolved
MSD ABOARD VESSEL NOT IN OPERATIONAL CONDITION. PUMPING OVERBOARD. 33 CFR179.7 (a)(1)(2).
Condition: Unknown
Due 11 November 2000
Resolved 16 November 2000