PISCES is a 2008 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2016, most recently in March 2026, along with 57 deficiencies, 10 operational controls and 13 casualty investigations between 2009 and 2026.

Records from 2009 to 2026. Most recent: operational control imposed, 28 March 2026.

Built
2008
Last inspected
28 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 March 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9550759
WDE7319
953529
Flag
UNITED STATES
Maury page id
psix-953529

Documentation record

Registered dimensions (L × B × D)112.4 ft × 28.7 ft × 12.3 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)112.4 ft × 28.7 ft × 12.3 ft
ITC tonnagegross 317 / net 98
BuilderICE FLOE LLC · FREELAND, WA, UNITED STATES · built 2008
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it317 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
98 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 38

28 March 2026 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8333473
28 March 2026 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8334213
29 August 2025 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8220530
29 August 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8228027
10 July 2025 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8182225
20 February 2025 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8085710
19 February 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8081793
18 July 2024 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7961173
26 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7920113
26 May 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7926343
9 November 2023 Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7821554
2 October 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7744582
25 August 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7776883
6 July 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7733657
21 April 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7673210
4 August 2022 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7579234
20 July 2022 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7497530
14 April 2022 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7431690
24 November 2021 Deficiency Check · Internal Structural Exam · Drydock Exam · Deadweight Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7359561
28 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7322621
29 July 2021 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7271933
15 April 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7176461
1 March 2021 Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7149028
26 February 2021 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7146631
30 September 2020 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7068940
19 November 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6929214
24 September 2019 MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6836701
1 August 2019 Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6769786
7 June 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6711126
31 October 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6572662
20 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6544614
19 July 2018 MTSA Verification · Internal Structural Exam · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6484804
6 September 2017 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6261312
6 September 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6269513
2 August 2017 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6228825
31 January 2017 COI Inspection · Deadweight Survey · Examination of Repairs · Drydock Exam · Annual Inspection · Construction Oversight · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6080557
23 August 2016 Damage Survey · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5982024
23 August 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5982321

Deficiency record · 57

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2026 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel had reported experiencing a loss of propulsion to PORT main engine; provide root cause analysis, effect repairs, and conduct satisfactory sea trial. Vessel is prohibited from carriage of passengers. Allowed one time transit to Alameda facility. 46 CFR 119.100
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2026
Resolution: Received satisfactory tech report from operator.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 July 2025 Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating, voids, and ballast, cargo, and fuel oil tanks. A cracked weld was observed below the waterline on hull plating butt joint starboard side void 3 between 6th and 7th inboard longitudinal, just forward of the forward most transverse frame. Conduct NDT to determine if crack extends into hull plating. 46 CFR 115.610(b)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 26 September 2025
Resolution: Operator sent photo of dye pen results indicating superficial crack. Photo uploaded to documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 July 2025 Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated... Multiple cable transits on the aft bulkhead of the stbd engine room and lazarette had mixed putty, remove and replace with one putty type. 46 CFR 116.415(a)(2)(ii)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 28 August 2025
Resolution: MI attended the vessel and verified correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 July 2025 Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, and has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. A nonmetallic hose in the port side generator wet exhaust system was not double clamped. 46 CFR 119.430(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2025
Resolved 28 August 2025
Resolution: MI attended the vessel and verified correction.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 July 2025 Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating, voids... Cracked welds observed during ISE to be repaired prior to 2026 credit drydock... 1. Overhead longitudinal in starboard void 3 at the top inboard side of the 2nd transverse swash bulkhead from forward. 2. Port void 2 at a deck stiffener above the first transverse frame.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2026
Resolved 28 August 2025
Resolution: MI attended the vessel and verified correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 February 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported limited propulsion on STBD engine with no alarms given and lack of prop wash. Provide root cause analysis of propulsion system issue, provide technician report for MI review, and conduct satisfactory sea trials to MI satisfaction. 46CFR119.200(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2025
Resolution: Vessel provided tech report and conducted satisfactory internal sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024 Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. MI observed port engine room fuel tank valve seized and unable to be operated from the pull outside of the compartment. 46 CFR 119.455(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2024
Resolved 18 July 2024
Resolution: Attended vessel and verified operation of pull
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 July 2024 Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. MI observed cable penetrations in port engine room aft bulkhead outboard, starboard engine room aft bulkhead, and under helm console in lower area behind ladder, missing or with inadequate fire-stop putty. 46 CFR 116.415(a)(2)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 18 July 2024
Resolution: Firestop putty installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel operator has stated that the vessel's port main engine is inoperable. Vessel to provide root cause and corrective action to the cognizant OCMI. 46 CFR 119.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2024
Resolved 30 May 2024
Resolution: Conducted sea trial.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 January 2024 Resolved
A-Class bulkheads or decks must be composed of steel or equivalent material...they must be so insulated with approved structual insulation. Bulkhead separating lazarette and port engine room missing insulation on engine room side all around access bolts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2024
Resolved 2 February 2024
Resolution: Verified SFP installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 October 2023 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. The vessel has not completed a drydock examination within the last two years. 46 CFR 115.600(d)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2024
Resolution: Vessel completed drydock inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. During initial operations on 8/19/23, vessel received high temp alarm for port main engine that was found to be due to a closed raw water valve. Operator took the vessel out of service on 8/19 and is working to repair associated damage to port main engine. Diagnose and effect repairs to the satisfaction of the local OCMI prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2024
Resolution: Damaged engine replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 July 2023 Resolved
For semiportable and fixed gas fire extinguishing systems... the owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector. No servicing report was available onboard. Provide servicing report to marine inspectors. 46 CFR 115.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 30 January 2024
Resolution: Old report obtained. Separate 835 still requires new servicing report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023 Resolved
Piping used in a vital system must meet § 56.60 in subchapter F of this chapter: Nonmetallic flexible hose may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths not exceeding 30 inches. Generator has two fuel hoses connected instead of one flexible hose. Repair fuel hose to be a single length of less than 30 inches. 46 CFR 119.710(c) 46 CFR 56.60-25(b)(4)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 11 August 2023
Resolution: Replaced hoses with single hose.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 July 2023 Resolved
A-Class bulkheads...must be so insulated with approved structural insulation, bulkhead panels, or deck covering... Pieces of insulation missing from engine room. Repair fire protection insulation to the satisfaction of the marine inspector. 46 CFR 116.415(a)(2)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 11 August 2023
Resolution: Repaired insulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 July 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (a) Operation of the main propulsion machinery both ahead and astern. Salt water leak found on starboard engine. Repair engine to the satisfaction of the marine inspector. 46 CFR 115.804(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2023
Resolved 30 January 2024
Resolution: Verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 July 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Holes found on deck above both steering spaces. Repair holes prior to next credit drydock. 46 CFR 115.802(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 January 2024
Resolution: Verified repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023 Resolved
Exhaust gas must not leak from the piping or any connections. Exhaust leaking from starboard engine. Repair exhaust leaks prior to next credit drydock. Complete prior to credit drydock. 46 CFR 119.430(b)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 30 January 2024
Resolution: Verified repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023 Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Temporary repairs were found on starboard generator exhaust. Make permanent repairs to exhaust system, prior to next credit drydock. 46 CFR 115.700(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 30 January 2024
Resolution: Verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 July 2023 Resolved
All electrical equipment and circuits must be clearly marked and identified. Multiple breakers were not labeled. Operator labeled breakers. 46 CFR 120.220(d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 July 2023
Resolution: Labeled breakers
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 July 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. No portable lights at operating station or machinery space. Operators procured new portable lights. 46 CFR 120.430
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 July 2023
Resolution: Obtained new portable lights.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 July 2023 Resolved
For semiportable and fixed gas fire extinguishing systems...If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Fire servicing report requires vessel to replace multiple components. Replace all components listed as defective in fire servicing report including Port FM-200 cylinder, cylinder bracket, N2 operated time delay, siren N2 cylinder, both brackets for N2 cylinders additional brackets on main deck, and Starboard FM-200 cylinder. After replacements have been completed, obtain new fire servicing report for replaced components to the satisfaction of the attending marine inspector. 46 CFR 115.810(b)(2) 21SEP23: Changed from 60 to 701 in order to allow vessel to complete engine repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2024
Resolution: Verified components installed with satisfactory replacement parts.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 20 July 2022 Resolved
A fire control plan must show escape routes, area of refuge, embarkation stations, compartment titles, and hazard clasification of accomodation and service spaces. Vessel must provide an adequate fire control plan with all appropriate criteria that is approved by the local OCMI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2022
Resolved 14 October 2022
Resolution: FCP was approved and posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2022 Resolved
Approved DVTP's must be completed to the satisfaction of the attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2022
Resolved 14 April 2022
Resolution: DVTP completed in entirety.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2022 Resolved
Plans must be submitted and approved for the modifcation to the installed fire extinguishing system that was modified for the engine upgrade.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2022
Resolved 14 April 2022
Resolution: Plans approved and system hydroes IAW type approval, all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 September 2021 Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees. Vessel has not assigned MMSI to applicable bridge VHF radios. 47 CFR 80.103(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2021
Resolved 29 September 2021
Resolution: MMSI has been assigned to VHF Radios.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 September 2021 Resolved
Where subject to moisture, a storage cylinder must be installed to provide a space of at least 51 millimeters (2 inches) between the deck and the bottom of the storage cylinder. FM200 cylinder was found sitting directly on the deck. Deficiency rectified on the spot.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 28 September 2021
Resolution: Repaired housing unit for fixed fire extinguisher.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2021 Resolved
At each subsequent inspection, the managing operator shall have the vessel ready for inspection of its fire protection equipment, including testing each firehose to a test pressure equivalent to its maximum service pressure. Vessel's fwd fire hose on the main deck discovered with a pinhole leak. Deficiency rectified on the spot.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2021
Resolution: Fire hose replaced in kind.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 September 2021 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Emergency lights were discovered burned out at the port and stbd fwd main deck EGRESS points. Deficiency corrected on spot.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 28 September 2021
Resolution: Bulbs replaced. Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 September 2020 Resolved
All escape hatches and other emergency exites must be marked on both sides in clearly legible letters at least 2 inches high "EMERGENCY EXIT, KEEP CLEAR". Port and Stbd escape hatches for the void spaces forward of the machinery space are not labeled on the inside.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2020
Resolved 1 October 2020
Resolution: Received pictures via email from vessel rep with posted emergency exit placards in each engine room.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 September 2020 Resolved
AS appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The vessel's chart was outdated.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 30 September 2020
Resolution: Deficiency Corrected on the spot. Chart was replaced with an up to date version.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 September 2020 Resolved
A vessel must carry a first-aid kit approved under approval series 160.041. The vessel's first aid kit was missing aspirin.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 30 September 2020
Resolution: Deficiency corrected on the spot. Added aspirin to the first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 24 September 2019 Resolved
The constuction and arrangment of the vessel must allow the safe operation of the vessel in accordance with the terms of the certificate of inspection. Multiple cracks witnessed along forward rails at the bow, and two cracks witnessed at the stbd rail along the aft (stbd quarter) of the vessel. Operator to make appropriate repairs to the satisfaction of the marine inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2019
Resolved 7 October 2019
Resolution: Operator submitted email with multiple photos showing repairs conducted on all cracked rails.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 October 2018 Resolved
USCG approved temporary weld repairs have been completed in the stbd machinery space fwd bulkhead adjacent to the stbd fuel tank. Temporary repairs have been proven satisfactory by visual inspection and air lance test. Vessel is authorized to operate with temporary repair until the next dry dock in July 2019. The crew must make a log and visual inspection of the repair twice daily while operating to ensure the continued integrity of the weld.
Action required: 705 - Other - as specified
Due 31 July 2019
Resolved 14 August 2019
Resolution: MI attended vessel to inspect final welds in both port and stbd engine rooms and air lance tests. Both port and stbd final welds and tests satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018 Resolved
ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 19 November 2018
Resolution: Vessel rep [name withheld] contacted Sector SF and confirmed vessel AIS to now be tranmitting vessel speicifics as appropriate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2018 Resolved
Each vessel must be provided with bilge pumps in accordance with §56.50-55 in subchapter F of this chapter. Bilge pumps in forward stbd void and stbd lazarette compartments were not properly operating. Pump in forward void could not dewater due to clogged check valve in the same space. Pump in lazarette had a broken seal for the top cover of its housing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2018
Resolved 27 July 2018
Resolution: Both pumps were repaired and proper operation witnessed by attending Marine Inspector.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 2 August 2017 Resolved
Missing proper structural fire protection where urea pipes pass through engine rooms towards centerline of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 30 August 2017
Resolution: Received photos attesting to proper structural fire protection.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 2 August 2017 Resolved
Design verification and Periodic Safety Test Procedures not approved by MSC.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 September 2017
Resolved 24 January 2018
Resolution: Conducted DVTP tests.
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017 Resolved
Provide updated drug testing program and prove enrollment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Company provided proof of enrollment.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 July 2017 Resolved
Provide servicable first aid kit; burn cream, aspirin, ammonia inhalants
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 2 August 2017
Resolution: Verified first aid kit items onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 July 2017 Resolved
Prove operation on starboard side aft life ring buoy waterlight and renew 3-6 foot lanyard and clip. (restricted to daylight ops)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: Witnessed proper operation of lifebuoy lights.
Navigation › Piloting/Steering › Marine Charts
Issued 24 July 2017 Resolved
Provide current charts, pubs and inland navigational rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 2 August 2017
Resolution: Required pubs/charts onboard.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 July 2017 Resolved
Provide valid certificate of documentation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Vessel provided COD.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 July 2017 Resolved
Provide IBA servicing records.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 2 August 2017
Resolution: Verified servicing records for IBAs.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 July 2017 Resolved
Conduct underway emergency drills.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Conducted satisfactory drills.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 July 2017 Resolved
Vessel is restricted to 150 passengers until CG-835 dated 07 July 17 #5 & 6 are cleared. (activity #6080557)
Action required: 705 - Other - as specified
Resolved 2 August 2017
Resolution: Items cleared.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 31 January 2017 Resolved
Repair crack on the port side frame connecting the transom deck approx 2 feet up from the deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2017
Resolution: Cracked was repaired
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2017 Resolved
Repair holed rub rail starboard side forward.
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 24 July 2017
Resolution: Rubrail repair was completed.
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2017 Resolved
Repair holed rub rail port side aft.
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 24 July 2017
Resolution: Rub rail repair was completed.
Engineering › Steering Gear System › Power Unit
Issued 31 January 2017 Resolved
Conduct sea trials for testing of steering and propulsion.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2017
Resolution: Completed sea trials and witnessed satisfactory K Boat steering test
Documentation › Certificates/Documents › Stability Letter
Issued 31 January 2017 Resolved
Provide stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Vessel provided stability letter.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 January 2017 Resolved
Provide fire control plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2017
Resolution: Fire control plan properly posted
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 January 2017 Resolved
Complete COI exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2017
Resolution: Completed COI inspection
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 31 January 2017 Resolved
Demonstrate fixed fire alarm in starboard engine room provides adequate volume.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2017
Resolution: Witnessed fire alarm on starboard side engine room with GFS technician onboard
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 31 January 2017 Resolved
Show proper operation of fire monitor panel on bridge. Showing battery failure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2017
Resolution: Fire monitor panel was witnessed by attending Marine Inspector.
Accommodation/Occupational Safety › Ventilation › General
Issued 31 January 2017 Resolved
Demonstrate operation of 08 dampers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2017
Resolution: Winessed pull test for 08 fire dampners.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 23 August 2016 Resolved
The starboard engine fuel pump pressure regulator has failed resulting in engine shut down. Vessel shall make repairs, complete sea trials and provide technical report of completed repairs.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2016
Resolution: satisfactory repairs completed.

Casualty record · 13

16 June 2009Routine · role: Involved in a Marine Casualty · activity 3510932
17 February 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3681246
17 September 2012Routine · role: Involved in a Marine Casualty · activity 4447147
10 April 2014Routine · role: Involved in a Marine Casualty · activity 4834018
20 May 2015Routine · role: Involved in a Marine Casualty · activity 5131406
23 August 2016Routine · role: Involved in a Marine Casualty · activity 5982321
6 September 2017Routine · role: Involved in a Marine Casualty · activity 6269513
7 June 2019Routine · role: Involved in a Marine Casualty · activity 6711126
4 August 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7579234
26 May 2024Routine · role: Involved in a Marine Casualty · activity 7926343
20 February 2025Routine · role: Involved in a Marine Casualty · activity 8085710
29 August 2025Routine · role: Involved in a Marine Casualty · activity 8228027
28 March 2026Routine · role: Involved in a Marine Casualty · activity 8334213
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.