Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Southwest District (CGD-SW) · Other hulls named PISCES
PISCES is a 2008 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 2007, most recently in March 2026, along with 67 deficiencies, 12 operational controls and 13 casualty investigations between 2009 and 2026.
Records from 2007 to 2026. Most recent: operational control imposed, 28 March 2026.
- Built
- 2008
- Last inspected
- 28 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 67 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 13 investigations · 2009–2026
Identity
1213095
9550759 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE7319
953529
Flag
UNITED STATES
—
Maury page id
psix-953529
Inspections, by type
…with no type recorded12
Years with a record
17 calendar years (2007–2026)
The 51 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)112.4 ft × 28.7 ft × 12.3 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)112.4 ft × 28.7 ft × 12.3 ft
ITC tonnagegross 317 / net 98
BuilderICE FLOE LLC · FREELAND, WA, UNITED STATES · built 2008
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it317 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
98 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
98 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 51
28 March 2026
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8333473
28 March 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8334213
29 August 2025
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8220530
29 August 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8228027
10 July 2025
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8182225
20 February 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8085710
19 February 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8081793
18 July 2024
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7961173
26 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7920113
26 May 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7926343
9 November 2023
Drydock Exam · Deficiency Check · Internal Structural Exam · Hull Examination · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7821554
2 October 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7744582
25 August 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7776883
6 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7733657
21 April 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7673210
4 August 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7579234
20 July 2022
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7497530
14 April 2022
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7431690
24 November 2021
Deficiency Check · Internal Structural Exam · Drydock Exam · Deadweight Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7359561
28 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7322621
29 July 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7271933
15 April 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7176461
1 March 2021
Drydock Extension · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7149028
26 February 2021
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7146631
30 September 2020
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7068940
19 November 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6929214
24 September 2019
MTSA Verification · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6836701
1 August 2019
Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6769786
7 June 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6711126
31 October 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6572662
20 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6544614
19 July 2018
MTSA Verification · Internal Structural Exam · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6484804
6 September 2017
Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6261312
6 September 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6269513
2 August 2017
Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6228825
31 January 2017
COI Inspection · Deadweight Survey · Examination of Repairs · Drydock Exam · Annual Inspection · Construction Oversight · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6080557
23 August 2016
Damage Survey · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5982024
23 August 2016
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5982321
17 December 2015
Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5777466
6 August 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5208408
6 August 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5212192
9 July 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4380934
3 July 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4366313
2 July 2012
Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4369677
5 January 2012
Damage Survey · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4219182
10 January 2011
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3922945
2 November 2010
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3903018
17 February 2010
Damage Survey · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3681040
17 February 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3681246
28 April 2009
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3431118
22 June 2007
Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3420992
Deficiency record · 67
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2026
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel had reported experiencing a loss of propulsion to PORT main engine; provide root cause analysis, effect repairs, and conduct satisfactory sea trial. Vessel is prohibited from carriage of passengers. Allowed one time transit to Alameda facility.
46 CFR 119.100
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 July 2025
Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating, voids, and ballast, cargo, and fuel oil tanks. A cracked weld was observed below the waterline on hull plating butt joint starboard side void 3 between 6th and 7th inboard longitudinal, just forward of the forward most transverse frame. Conduct NDT to determine if crack extends into hull plating. 46 CFR 115.610(b)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 July 2025
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated... Multiple cable transits on the aft bulkhead of the stbd engine room and lazarette had mixed putty, remove and replace with one putty type. 46 CFR 116.415(a)(2)(ii)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 July 2025
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, and has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. A nonmetallic hose in the port side generator wet exhaust system was not double clamped. 46 CFR 119.430(e)
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 July 2025
Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating, voids... Cracked welds observed during ISE to be repaired prior to 2026 credit drydock...
1. Overhead longitudinal in starboard void 3 at the top inboard side of the 2nd transverse swash bulkhead from forward.
2. Port void 2 at a deck stiffener above the first transverse frame.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 February 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel reported limited propulsion on STBD engine with no alarms given and lack of prop wash. Provide root cause analysis of propulsion system issue, provide technician report for MI review, and conduct satisfactory sea trials to MI satisfaction. 46CFR119.200(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 July 2024
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. MI observed port engine room fuel tank valve seized and unable to be operated from the pull outside of the compartment. 46 CFR 119.455(b)(3)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 July 2024
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. MI observed cable penetrations in port engine room aft bulkhead outboard, starboard engine room aft bulkhead, and under helm console in lower area behind ladder, missing or with inadequate fire-stop putty. 46 CFR 116.415(a)(2)(ii)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Vessel operator has stated that the vessel's port main engine is inoperable. Vessel to provide root cause and corrective action to the cognizant OCMI.
46 CFR 119.100
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 January 2024
Resolved
A-Class bulkheads or decks must be composed of steel or equivalent material...they must be so insulated with approved structual insulation. Bulkhead separating lazarette and port engine room missing insulation on engine room side all around access bolts.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 October 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every two years. The vessel has not completed a drydock examination within the last two years.
46 CFR 115.600(d)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 August 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. During initial operations on 8/19/23, vessel received high temp alarm for port main engine that was found to be due to a closed raw water valve. Operator took the vessel out of service on 8/19 and is working to repair associated damage to port main engine. Diagnose and effect repairs to the satisfaction of the local OCMI prior to carrying passengers.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 July 2023
Resolved
For semiportable and fixed gas fire extinguishing systems... the owner or managing operator shall provide satisfactory evidence of the required servicing to the marine inspector. No servicing report was available onboard. Provide servicing report to marine inspectors. 46 CFR 115.810(b)(2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023
Resolved
Piping used in a vital system must meet § 56.60 in subchapter F of this chapter: Nonmetallic flexible hose may be used in lube oil, fuel oil and fluid power systems only where flexibility is required and in lengths not exceeding 30 inches. Generator has two fuel hoses connected instead of one flexible hose. Repair fuel hose to be a single length of less than 30 inches. 46 CFR 119.710(c)
46 CFR 56.60-25(b)(4)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 6 July 2023
Resolved
A-Class bulkheads...must be so insulated with approved structural insulation, bulkhead panels, or deck covering... Pieces of insulation missing from engine room. Repair fire protection insulation to the satisfaction of the marine inspector. 46 CFR 116.415(a)(2)(i)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 July 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (a) Operation of the main propulsion machinery both ahead and astern. Salt water leak found on starboard engine. Repair engine to the satisfaction of the marine inspector. 46 CFR 115.804(a)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 July 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. Holes found on deck above both steering spaces. Repair holes prior to next credit drydock. 46 CFR 115.802(a)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023
Resolved
Exhaust gas must not leak from the piping or any connections. Exhaust leaking from starboard engine. Repair exhaust leaks prior to next credit drydock. Complete prior to credit drydock. 46 CFR 119.430(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2023
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Temporary repairs were found on starboard generator exhaust. Make permanent repairs to exhaust system, prior to next credit drydock. 46 CFR 115.700(d)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 July 2023
Resolved
All electrical equipment and circuits must be clearly marked and identified. Multiple breakers were not labeled. Operator labeled breakers. 46 CFR 120.220(d)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 July 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. No portable lights at operating station or machinery space. Operators procured new portable lights. 46 CFR 120.430
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 July 2023
Resolved
For semiportable and fixed gas fire extinguishing systems...If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Fire servicing report requires vessel to replace multiple components. Replace all components listed as defective in fire servicing report including Port FM-200 cylinder, cylinder bracket, N2 operated time delay, siren N2 cylinder, both brackets for N2 cylinders additional brackets on main deck, and Starboard FM-200 cylinder. After replacements have been completed, obtain new fire servicing report for replaced components to the satisfaction of the attending marine inspector. 46 CFR 115.810(b)(2) 21SEP23: Changed from 60 to 701 in order to allow vessel to complete engine repairs.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 20 July 2022
Resolved
A fire control plan must show escape routes, area of refuge, embarkation stations, compartment titles, and hazard clasification of accomodation and service spaces. Vessel must provide an adequate fire control plan with all appropriate criteria that is approved by the local OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 March 2022
Resolved
Approved DVTP's must be completed to the satisfaction of the attending Marine Inspector prior to carrying passengers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 March 2022
Resolved
Plans must be submitted and approved for the modifcation to the installed fire extinguishing system that was modified for the engine upgrade.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 28 September 2021
Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees. Vessel has not assigned MMSI to applicable bridge VHF radios.
47 CFR 80.103(b)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 September 2021
Resolved
Where subject to moisture, a storage cylinder must be installed to provide a space of at least 51 millimeters (2 inches) between the deck and the bottom of the storage cylinder. FM200 cylinder was found sitting directly on the deck. Deficiency rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2021
Resolved
At each subsequent inspection, the managing operator shall have the vessel ready for inspection of its fire protection equipment, including testing each firehose to a test pressure equivalent to its maximum service pressure. Vessel's fwd fire hose on the main deck discovered with a pinhole leak. Deficiency rectified on the spot.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 September 2021
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Emergency lights were discovered burned out at the port and stbd fwd main deck EGRESS points. Deficiency corrected on spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 30 September 2020
Resolved
All escape hatches and other emergency exites must be marked on both sides in clearly legible letters at least 2 inches high "EMERGENCY EXIT, KEEP CLEAR". Port and Stbd escape hatches for the void spaces forward of the machinery space are not labeled on the inside.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 30 September 2020
Resolved
AS appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The vessel's chart was outdated.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 September 2020
Resolved
A vessel must carry a first-aid kit approved under approval series 160.041. The vessel's first aid kit was missing aspirin.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 24 September 2019
Resolved
The constuction and arrangment of the vessel must allow the safe operation of the vessel in accordance with the terms of the certificate of inspection. Multiple cracks witnessed along forward rails at the bow, and two cracks witnessed at the stbd rail along the aft (stbd quarter) of the vessel. Operator to make appropriate repairs to the satisfaction of the marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 October 2018
Resolved
USCG approved temporary weld repairs have been completed in the stbd machinery space fwd bulkhead adjacent to the stbd fuel tank. Temporary repairs have been proven satisfactory by visual inspection and air lance test. Vessel is authorized to operate with temporary repair until the next dry dock in July 2019. The crew must make a log and visual inspection of the repair twice daily while operating to ensure the continued integrity of the weld.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018
Resolved
ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2018
Resolved
Each vessel must be provided with bilge pumps in accordance with §56.50-55 in subchapter F of this chapter. Bilge pumps in forward stbd void and stbd lazarette compartments were not properly operating. Pump in forward void could not dewater due to clogged check valve in the same space. Pump in lazarette had a broken seal for the top cover of its housing.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 2 August 2017
Resolved
Missing proper structural fire protection where urea pipes pass through engine rooms towards centerline of the vessel.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 2 August 2017
Resolved
Design verification and Periodic Safety Test Procedures not approved by MSC.
Documentation › Logs/Records › Drug Test Records
Issued 24 July 2017
Resolved
Provide updated drug testing program and prove enrollment.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 July 2017
Resolved
Provide servicable first aid kit; burn cream, aspirin, ammonia inhalants
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 July 2017
Resolved
Prove operation on starboard side aft life ring buoy waterlight and renew 3-6 foot lanyard and clip. (restricted to daylight ops)
Navigation › Piloting/Steering › Marine Charts
Issued 24 July 2017
Resolved
Provide current charts, pubs and inland navigational rules.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 July 2017
Resolved
Provide valid certificate of documentation.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 24 July 2017
Resolved
Provide IBA servicing records.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 24 July 2017
Resolved
Conduct underway emergency drills.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 July 2017
Resolved
Vessel is restricted to 150 passengers until CG-835 dated 07 July 17 #5 & 6 are cleared. (activity #6080557)
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 31 January 2017
Resolved
Repair crack on the port side frame connecting the transom deck approx 2 feet up from the deck.
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2017
Resolved
Repair holed rub rail starboard side forward.
Construction/Loadline › Structures › Deck Plating
Issued 31 January 2017
Resolved
Repair holed rub rail port side aft.
Engineering › Steering Gear System › Power Unit
Issued 31 January 2017
Resolved
Conduct sea trials for testing of steering and propulsion.
Documentation › Certificates/Documents › Stability Letter
Issued 31 January 2017
Resolved
Provide stability letter.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 January 2017
Resolved
Provide fire control plan.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 31 January 2017
Resolved
Complete COI exam.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 31 January 2017
Resolved
Demonstrate fixed fire alarm in starboard engine room provides adequate volume.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 31 January 2017
Resolved
Show proper operation of fire monitor panel on bridge. Showing battery failure.
Accommodation/Occupational Safety › Ventilation › General
Issued 31 January 2017
Resolved
Demonstrate operation of 08 dampers.
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 23 August 2016
Resolved
The starboard engine fuel pump pressure regulator has failed resulting in engine shut down. Vessel shall make repairs, complete sea trials and provide technical report of completed repairs.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 December 2015
Resolved
Repair leak in the port fuel tank. Test with Marine Inspector present. 46CFR182.440
Prior to carrying passengers.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 17 December 2015
Resolved
Replace missing aft port mooring cleat to the satisfaction of attending marine inspector. 46CFR184.300. Prior to carrying passengers.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 17 December 2015
Resolved
Temporary repairs were completed to the crack on the port fuel tank. Permanent repairs (crop and renew) required during next drydock in Jan 2017. 46CFR182.440
Documentation › Logs/Records › Drug Test Records
Issued 2 November 2010
Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 2 November 2010
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 2 November 2010
Resolved
Supervisors have no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 2 November 2010
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Documentation › Logs/Records › Drug Test Records
Issued 2 November 2010
Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Construction/Loadline › Hull › Bottom Plating
Issued 17 February 2010
Resolved
Provide a repair proposal to allision damage on: the Transom shell plating, Bottom tunnel shell plate, Side shell plating and deck shell plate. Repair affected damage IAW the repair proposal, once approved.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 April 2009
Resolved
Arrange and Label child sized PFD locations and separate from adult PFD's.
Casualty record · 13
16 June 2009Routine · role: Involved in a Marine Casualty · activity 3510932
17 February 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3681246
17 September 2012Routine · role: Involved in a Marine Casualty · activity 4447147
10 April 2014Routine · role: Involved in a Marine Casualty · activity 4834018
20 May 2015Routine · role: Involved in a Marine Casualty · activity 5131406
23 August 2016Routine · role: Involved in a Marine Casualty · activity 5982321
6 September 2017Routine · role: Involved in a Marine Casualty · activity 6269513
7 June 2019Routine · role: Involved in a Marine Casualty · activity 6711126
4 August 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7579234
26 May 2024Routine · role: Involved in a Marine Casualty · activity 7926343
20 February 2025Routine · role: Involved in a Marine Casualty · activity 8085710
29 August 2025Routine · role: Involved in a Marine Casualty · activity 8228027
28 March 2026Routine · role: Involved in a Marine Casualty · activity 8334213
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.