Records from 2016 to 2021. Most recent: inspection, 22 November 2021.
Inspection history · 13
22 November 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7356097
5 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6948572
19 November 2019
Administrative Inspection · DAPI Audit · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6843370
30 May 2019
Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6699061
23 January 2019
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6610051
21 November 2018
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6579368
3 May 2018
Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6403805
18 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6290871
24 February 2017
Deficiency Check · COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6091704
28 November 2016
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6048540
30 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5988556
9 February 2016
COI Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5811855
14 January 2016
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5799318
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 May 2020
No resolution recorded
Per MSIB 0920 and due to COVID-19, the vessel is granted a 90 day drydock extension to be conducted no later than 31AUG20. Vessel is not in operations at the moment and will require the drydock inspection prior to carrying passengers.
Action required: 705 - Other - as specified
Due 31 August 2020 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 November 2019
No resolution recorded
Discovered that on the prior COI it still showed that the vessel had installed IBAs. At the inspection, the vessel had life floats installed. Of the 8 life floats installed, only one had the manufacturer plate and approval information. Due to the lack of available resources on the islands, the new life floats will take 6 weeks to arrive. CG-835 issued to replace the life floats, which will be due on 31DEC19. The vessel will be allowed to operate with the installed life floats until then.
Action required: 705 - Other - as specified
Due 31 December 2019 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019
Resolved
Remove power strips observed behind helm prior to conducing passenger operations in U.S. waters.
Action required: 705 - Other - as specified
Resolved 29 January 2019
Resolution: Vessel removed power strips.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 January 2019
Resolved
Provide protection from electric shock on front and back of distribution panel on port side of bridge prior to conducting passenger operations in U.S. waters.
Action required: 705 - Other - as specified
Resolved 29 January 2019
Resolution: Vessel provided blanks.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2018
Resolved
Submit drawings of batteries and associated electrical system to Marine Safety Center for approval.46 CFR 177.202 (b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2018
Resolved 24 April 2019
Resolution: Cleared
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 November 2018
Resolved
Provide inspection report for fixed CO2 firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2018
Resolution: Received satisfactory service report from CaribSupply.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 November 2018
Resolved
Provide J-SAE 1942 hose for port side generator fuel piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Hoses provided and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 November 2018
Resolved
Replace flywheel screen and generator cover for port side generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2019
Resolution: Guard provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 November 2018
Resolved
Properly plug port side generator crank case to remove wood dowel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2019
Resolution: Proper plug provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 November 2018
Resolved
Repair cooling water leak on port side generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2019
Resolution: Water leak repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2018
Resolved
Remove or properly terminate dead end wires behind helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Vessel secured dead end wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2018
Resolved
Provide cover for junction box behind helm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Junction box cover provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 November 2018
Resolved
Provide current first aid kit contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2019
Resolution: New first aid kit provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2018
Resolved
Provide ventilation for battery storage cabinet.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2019
Resolution: Ventilation holes cut into cabinet door.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2018
Resolved
Properly secure air condition units on upper deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2019
Resolution: Air conditioning units secured.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 November 2018
Resolved
Provide appropriate batteries for all water lights.(09)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2019
Resolution: Batteries provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 November 2018
Resolved
Properly mark life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2019
Resolution: Life floats marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2018
Resolved
Provide check valves for both port & starboard bilge piping to fuel tank spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2019
Resolution: Vessel provided check valves.
Construction/Loadline › Hull › Hull Plating
Issued 18 October 2017
Resolved
Water ingress in stbd rudder space. Crew used foam spray to stop leakage. Permanent repairs are to be made by 31OCT17.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 3 May 2018
Resolution: Vessel repaired leak during drydock.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 24 February 2017
Resolved
2 portable fire extinguishers need servicing
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 8 March 2017
Resolution: replaced portable fire extinguishers
Lifesaving › Lifefloat › Lifeline
Issued 24 February 2017
Resolved
replace grab lines
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 8 March 2017
Resolution: renewd grab lines
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 February 2017
Resolved
replace grab line on fwd ring buoy
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 8 March 2017
Resolution: renewed grab lines
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 25 February 2016
Resolved
Provide updated tide tables, light list and Coast Pilot.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 30 August 2016
Resolution: Vessel aquired all required nav safety publications.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 February 2016
Resolved
Prove proper operation of GPS enabled DSC-VHF Radio.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 30 August 2016
Resolution: DSC radios as well as AIS installed and programmed.
Engineering › Steering Gear System › Ram Seal
Issued 25 February 2016
Resolved
Repair or replace starboard steering ram seal.
Action required: 705 - Other - as specified
Due 10 March 2016
Resolved 30 August 2016
Resolution: Seal replaced and no leak noted.