Records from 2016 to 2026. Most recent: inspection, 4 March 2026.
Inspection history · 19
4 March 2026
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8307108
25 September 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8239207
10 October 2024
Drydock Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8017596
10 October 2023
Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7803022
11 October 2022
Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7577487
2 June 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7466896
18 January 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7382103
19 October 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7333704
30 March 2021
Deadweight Survey · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7169779
22 July 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7071999
20 November 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6859628
7 October 2019
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6819341
24 June 2019
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6721620
2 November 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6583829
8 May 2018
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6414125
13 October 2017
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6286301
11 May 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6133869
20 October 2016
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6026692
5 May 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5869674
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 October 2025
No resolution recorded
The construction of a vessel must allow for safe operation, giving consideration to a seaworthy hull, of the vessel. The internal baffles separating the chambers of the pontoon were found leaking during the Over Pressure Stress Test.
Coordinate and effect repairs with pontoon manufacturer recommendations. Schedule marine inspector attendance once repairs are completed.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 January 2026 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2021
Resolved
Inflation valve on stbd side sponson chamber #4 (fore to aft counting), found leaking from soap solution bubbling.
46 CFR 176.840
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 26 October 2021
Resolution: Repaired leaking valve on sponson