Records from 2016 to 2026. Most recent: inspection, 11 March 2026.
Documentation record
Registered dimensions (L × B × D)39.8 ft × 12.7 ft × 4.5 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderL O'NEAL JONES · TODDVILLE, MD, UNITED STATES · built 1968
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHESAPEAKE BEACH, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 6 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Net Ton
15 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
11 March 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8325261
15 January 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8296735
21 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8256162
22 January 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8067508
12 March 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7877786
6 February 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7861495
18 January 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7623310
19 October 2022
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7583363
19 January 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7127064
3 November 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7093958
30 October 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7087293
7 May 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6949639
21 April 2020
Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6941737
16 January 2020
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6888113
22 October 2019
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6840247
27 March 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6655814
6 November 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6301387
9 December 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6055371
31 October 2016
Drydock Exam · DAPI Audit · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6031180
28 July 2016
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5955787
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 January 2026
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter. The vessels life float painter was not secured to the vessel. Vessel is restricted from carrying passengers during cold water months 01NOV-14MAY.
46CFR180.130(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2026
Resolution: Received photo of the life float painter and weak link secured to the vessel.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 15 January 2026
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include—(1) Closing the seacock and removing the handle;(2) Padlocking the seacock in the closed position;(3) Using a non-releasable wire-tie to hold the seacock in the closed position; or locking the door to the space enclosing the toilets with a padlockor door handle key lock. Vessel has type I MSD and
operates in some no discharge zones with discharge valve
open. Operator closed valve.
33CFR159.7(b)
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Operater closed valve.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 January 2026
Resolved
t least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:(1) Be buoyant;(2) Be of at least 18.3 meters (60 feet) in length;(3) Be non-kinking;(4) Have a diameter of at least 7.9 millimeters (5/16 inch);(5)Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Ring buoy life line was dry rotted and not serviceable.
46CFR180.70(c)
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
Resolution: Life line was replaced. All sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 15 January 2026
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. VHF radio did not have the vessels MMSI number programmed in it. Corrected on the spot.
46CFR184.502
Action required: 10 - Deficiency Rectified
Resolved 15 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 January 2025
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. The grab line was cut and needs to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2025
Resolution: Received photos of new life ring.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Portable extinguishers and Fireboy are past due on the annual servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2025
Resolution: Received photos of annual fire fighting servicing tags
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 January 2025
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel did not have a current contract with a consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2025
Resolution: Received photo of new drug consortium contract
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2024
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Life ring's waterlight lanyard's non-corrosive clip was inop.
46 CFR 180.70(d)(3)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2024
Resolution: Corrected on the spot. New clip was added.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 February 2024
Resolved
A whistle fitted in a vessel shall provide, in the direction of maximum intensity of the whistle and at a distance of 1 meter from it, a sound pressure level in at least one 1/3rd-octave band within the range of frequencies 180–700 Hz (±1%) for a vessel of 20 meters or more in length, or 180–2100 Hz (±1%) for a vessel of less than 20 meters in length, of not less than the appropriate figure given in Table 86.01(c) of this section. Vessel was nissing operable sound signal.
33CFR86.01(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2024
Resolution: A new sound signal was purchased and added to the vessel. Cleared on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 January 2023
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Water intake hose for the port MDE had a severe kink due to the hose material being inadequate for vacuum/pressure.
46 CFR 182.720(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 January 2025
Resolution: Verified the hose was replaced during the annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 30 October 2020
Resolved
The weight and associated vertical center of gravity of variable loads must be included as appropriate for the service intended and documented in the stability information. A new Simplified Stability Test (SST) was conducted to include newly installed the Upper Helm Station. Based on the results from the SST, the vessel can carry a maximum of 24 passengers and 01 crew member during warm water months.
46 CFR 178.300 (a)(iii)
Action required: 705 - Other - as specified
Due 30 October 2020
Resolved 2 November 2020
Resolution: SST Conducted and passenger count reduced. New Stability Letter and COI issued to vessel O/O
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 May 2020
Resolved
The vessel’s passenger count has been reduced to 25 passengers and 1 crew member (total of 25 persons on board). This reduction is in conjunction with the recent simplified stability test that was conducted due to the installation of the Upper Deck Helm Station on the vessel’s canopy.
Note: This deficiency will be cleared upon the completion of the new Stability Letter and new COI reflecting the new data from the recent simplified stability test.
Action required: 705 - Other - as specified
Due 14 July 2020
Resolved 17 August 2020
Resolution: Validated count.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 21 April 2020
Resolved
The weight and associated vertical center of gravity of variable loads must be included as appropriate for the service intended and documented in the stability information.
ACTION:
The vessel will need to satisfactorily pass a new Simplified Stability Test to include the Upper Helm Station. Note: Vessel recently added an Upper Helm Station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2020
Resolved 5 May 2020
Resolution: The vessel successfully passed a new Simplified Stability Test (SST) which include calculations for the Upper Helm Station. Based on the results from the SST; the vessel can carry a maximum of 24 passengers and 02 crew members.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 21 April 2020
Resolved
The weight and associated vertical center of gravity of variable loads must be included as appropriate for the service intended and documented in the stability information.
ACTION:
A new Simplified Stability Test (SST) was conducted to include the Upper Helm Station. Note: Vessel recently added an Upper Helm Station to its canopy area. Based on the results from the SST; the vessel can carry a maximum of 24 passengers and 02 crew members.
Action required: 705 - Other - as specified
Due 5 May 2020
Resolved 5 May 2020
Resolution: Duplicate
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 January 2020
Resolved
Vessel required to conduct Underway fire and abandon ship drill. Unable to conduct drill due to gale force winds.
Action required: 705 - Other - as specified
Resolved 7 May 2020
Resolution: Witnessed satisfactory U/W Drills, ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 January 2020
Resolved
Pre-engineered fixed gas fire extinguishing systems must be equipped with an auditable alarm. Vessels audible alarm system not functioning as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2020
Resolution: Witness satisfactory operation of the vessel's installed fire fighting system - including visual and audible alarms, ALL SAT.