Records from 2008 to 2026. Most recent: inspection, 28 May 2026.
Documentation record
Registered dimensions (L × B × D)26.0 ft × 10.3 ft × 5.0 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSHAW YACHT INC · THOMASTON, UNITED STATES · built 2007
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLORAIN, OH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
28 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8381591
25 June 2025
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8166102
26 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7942708
15 May 2023
COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7688916
5 July 2022
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7496863
20 April 2022
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7434478
11 August 2021
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7283389
30 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7103578
1 September 2020
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7047684
6 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7025591
8 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6679389
16 May 2018
COI Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6395448
18 April 2017
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6127319
5 May 2016
Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5869449
13 May 2014
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4856338
2 July 2012
Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4380866
4 May 2012
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4301174
7 September 2011
Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4176469
14 May 2009
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3474896
28 May 2008
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3220698
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 August 2020
Resolved
Missing three (3) daytime flares. Replenish missing flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 1 September 2020
Resolution: All required pyrotechnics are onboard. Cleared deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2020
Resolved
Label access cover to fuel shut-off valves.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 1 September 2020
Resolution: Fuel shut-off valve locations are now properly marked. Deficiency cleared.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 August 2020
Resolved
Anchor light is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2020
Resolved 1 September 2020
Resolution: Anchor light is functioning properly. Deficiency is cleared.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 May 2012
Resolved
Install a positive shutt-off valves at the hull penetration on the bilge pump hose lines.
Due 1 June 2012
Resolved 2 July 2012
Resolution: Shut-off valves were installed in-line.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 May 2009
Resolved
During the inspection, the master was unable to start the main diesel engine due to an insufficiently charged battery. Upon restoration of the vessel's electrical system we will get underway to complete the inspection by observing underway drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2009
Resolved 21 May 2009
Resolution: Attended vessel, operated vessel, tested haead and astern propulsion, steering electronics satisfactory.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 May 2009
Resolved
Vessel had the appropriate chart for their area of operation but it was not updated with the current corrections. The vessel was also missing the appropriate parts of the U.S. Coast Pilot and local Light List.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2009
Resolution: Sighted corrected charts, appliciable portions of Coast Pilot and Light List on board.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 May 2009
Resolved
Vessel does not have an Employee Assistance Program in place at this time. Educated the owner's representative and master of the requirement.
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 9 July 2009
Resolution: Reviewed satisfactory this date.
Lifesaving › Lifejacket/PFD (General) › Size
Issued 28 May 2008
Resolved
Post placard for child size life jackets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Donning placard for child-size life jackets posted next to adult donning placard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 May 2008
Resolved
Separate child size life jackets from adult size life jacket.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Childsize life jackets segregated properly on-board with proper labeling to be distinct from adult life jackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 May 2008
Resolved
Replace battery in water light and attach water light to lifebuoy.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Battery in waterlight replaced.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 May 2008
Resolved
Post emergency broadcast placard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Emergency broadcast placard posted adjacent to helm/radio in easily readable position.
Fire Fighting › Ventilation Systems › Ducts
Issued 28 May 2008
Resolved
Provide ventilation closure for machinery vents.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Manual PVC closure devices installed for each engine compartment ventillation space.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 28 May 2008
Resolved
Service fixed fire fighting system and portable fire fighting extinguishers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Fixed fire extinguishing system inspeceted and serviced properly. Vessel maintains receipt/documentation in logbook/document folder.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 May 2008
Resolved
Log all required drill and training
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Logbook created and maintained on-board vessel documentation folder. All training, drills, and exercises to be logged accordingly.
Construction/Loadline › Structures › Superstructure
Issued 28 May 2008
Resolved
Increase height of handrails to 39.5" around the course of vessel.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Rail course/line installed to at least 39.5" to comply with requirement all around vessel.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 May 2008
Resolved
Provide two portable lights onboard vessels.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 6 June 2008
Resolution: Two flashlights with operating batteries purchased and available on-board vessel.