MAURY USCG vessel records
← All vessels

RIDGEBURY CAPTAIN DROGIN

RIDGEBURY CAPTAIN DROGIN is a 2007 tank ship. The Coast Guard has recorded 4 inspections since 2016, most recently in April 2022, along with 4 deficiencies.

Records from 2016 to 2022. Most recent: inspection, 2 April 2022.

Built
2007
Last inspected
2 April 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 April 2022
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9320714
955510
Flag
MARSHALL ISLANDS
Maury page id
psix-955510

Documentation record

Tonnage as PSIX records it86952 - Convention (Subpart B), Gross Ton
166467 - Dead Weight, Metric Ton
193339 - Displacement, Metric Ton
53460 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

4 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

2 April 2022 Administrative Inspection · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7423248
26 February 2022 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7398752
8 February 2018 COC-TVE Renew · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6350624
25 April 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5856732

Deficiency record · 4

Deck/Cargo › Inert Gas System › Main Valve
Issued 8 February 2018 Resolved
The Inert Gas system shall be capable of inerting, purging and gas freeing empty tanks and maintaining atmosphere in cargo tanks with required oxygen content. PSCO was informed by crew that oxygen analyzer is not operable.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2018
Resolved 10 February 2018
Resolution: Attended vessel and completed IGS testing after receiving a Class survey attesting to the proper installation of the O2 sensor.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 25 April 2016 Resolved
1820 - Means shall be provided to control leaks of flammable liquids. PSCO observed on the lower bearing region of both the #1 and #3 cargo pumps some cargo residue that had leaked during a previous discharge operation. Prior to operation of #1 and #3 cargo pumps to the satisfaction of Recognized Organization. SOLAS 74 a (14) II-1/4.1.1. Prior to operation of #1 and #3 cargo pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2016
Resolved 26 April 2016
Resolution: 26APR2016: Received class report from DNV-GL stating that the deficiency had been rectified. The class report stated that the mechanical seals were tightened on #1 & #3 cargo pumps, a function test was carried out and there were no signs of leakage.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 25 April 2016 Resolved
1870 - Special consideration shall be given to the design and location of scrubber and blowers with relevant piping and fittings in order to prevent flue gas leakages into enclosed spaces. PSCO observed that the rubber coupling on the outtake side of the #2 IG blower was cracked around the entire circumference of the coupling. SOLAS 74 a (14) II-1/4.5.5.3.2, FSS Code 15.2.3.1.2.1. 16a.
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 26 April 2016
Resolution: 26APR2016: Received class report from DNV-GL stating the deficiency had been rectified. The class report stated that the cracked rubber coupling was removed and replaced by a new rubber coupling.
Documentation › Markings/Placards › Warning Signs
Issued 25 April 2016 Resolved
1099 - The tank overfill alarm required by paragraph (a) of this section must be identified with the legend "TANK OVERFILL ALARM" in black letters at least 2 inches on a white background. PSCO observed that the vessel's overfill alarm tower that was located forward and starboard of the manifold had a weathered legend that was not legible from the aft end of the tower. 46 CFR 39.2007(d). 16c.
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 26 April 2016
Resolution: 26APR2016: Received class report from DNV-GL stating that the deficiency has been rectified. The class report stated (and showed with photographic evidence) that the signed had been properly repainted.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.