Inspection history · 56
1 April 2026
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8340133
20 March 2026
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8329249
16 March 2026
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8345812
29 July 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8203681
21 May 2025
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 8141014
22 October 2024
Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 8023039
13 September 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8001927
6 May 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7908190
4 April 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7890149
5 June 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7706358
15 May 2023
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7688595
4 May 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7444055
7 April 2022
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7426745
17 May 2021
Administrative Inspection
Administrative · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 7199149
29 April 2021
Periodic Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7186389
18 March 2021
Deadweight Survey · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7158550
22 January 2021
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7128685
17 June 2020
Annual Inspection
Physical examination · Detached Duty Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 6979267
26 November 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6868012
17 May 2019
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6686569
26 April 2019
Deficiency Check · Examination of Repairs · Drydock Exam · Administrative Inspection · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6670971
7 December 2018
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6709796
25 July 2018
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6496915
28 June 2018
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6458885
30 October 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6297868
17 October 2017
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6291866
3 August 2017
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6230516
9 May 2017
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6142410
19 April 2017
Bulk Liquid Transfer Monitor
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 6128433
27 May 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5888593
12 May 2016
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5875836
17 March 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5835461
27 January 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5805423
2 December 2015
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5773923
4 June 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5144169
5 May 2015
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5118683
23 March 2015
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5089100
25 February 2015
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5074755
18 February 2015
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5072146
13 February 2015
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5068779
27 January 2015
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 5059890
10 April 2014
Drydock Exam · MTSA Verification · Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4833208
23 October 2013
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4740418
23 October 2012
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4470628
11 June 2012
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4340470
15 February 2012
MTSA Verification · Internal Structural Exam · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4245398
18 January 2012
In-Service Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4227179
13 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4224598
13 December 2011
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4207412
26 October 2011
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4180084
27 September 2011
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4155107
29 July 2011
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4101667
26 July 2011
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 4106138
15 March 2010
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3695953
10 March 2010
MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3695886
25 May 2008
Hull Examination · Construction Oversight · MTSA Verification · Internal Structural Exam · Deadweight Survey · Cargo Tank Internal · Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3468635
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2025
Resolved
At least one life buoy on each side of vessel shall be fitted with a buoyant lifeline. Lifeline on life buoy is worn.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 11 July 2025
Resolved 11 July 2025
Resolution: Replaced line.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 28 May 2024
Resolved
Tank overfill "high-high" alarm was inoperable during inspection. Restore proper operation of alarm IAW 46 CFR 39.2007(d) prior to 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2024
Resolved 3 June 2024
Resolution: Vessel rep sent videos from main deck and cargo control room demonstrating proper operation of alarm.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 15 May 2023
Resolved
The vessel must maintain a ballast water management plan that has been developed specifically for the vessel and must include the items detailed in 33 CFR 151.2050(g)(1)-(7). The ballast plan provided by the Master is not specific to the vessel, does not contain all the information required, and makes reference to outdated CFR cites. Update the ballast water management plan to meet the requirements of 33 CFR 151.2050(g).
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2023
Resolved 5 June 2023
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 15 May 2023
Resolved
The vessel claims exemption from 33 CFR 151.2025 which exempts non-seagoing vessels (vessels operating within the boundary lines established in 46 CFR Part 7) from meeting this specific requirement. However, the vessel's current Certificate of Inspection (COI) allows for operation on an "Oceans" route, which would allow operation beyond the boundary lines and would subject the vessel to the requirements of 46 CFR 151.2025. The owner/operator must request a reduction in route on the COI to operation with the boundary line (i.e. Great Lakes) OR must employ one of the ballast water management methods outlined in 33 CFR 151.2025(a)(1)-(5). The method chosen and procedures for implementation
shall be addressed in the Ballast Water Management Plan.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2023
Resolved 5 June 2023
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 15 May 2023
Resolved
#5 STBD cargo tank alarm wiring is not secured in stuffing tube creating hazardous condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2023
Resolution: Wiring was secured into stuffing tube properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2022
Resolved
Both Ring buoys forward and aft have deteriorated/ broken rescue line. Repair of replace lines, at least 100' and attached to ring buoys.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2022
Resolution: Life ring line was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 April 2022
Resolved
Lower level engine space has a required Semi-portable extinguisher that is discharged and in need of service. Conduct service or replace extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2022
Resolution: Extinguisher was serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 April 2022
Resolved
Motor controller center on PORT side of the upper engine space has open breaker slot that needs cover to protect crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2022
Resolution: rcvd proof that panel voids were covered properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 29 April 2021
Resolved
No extensive alterations involving the safety of the tank vessel in regard to the hull or machinery shall be made without approval from the Commandant; prior to the beginning of work plans are to be submitted to the OCMI. Vessel made repairs to tank top without submitting plans or showing approved plans from ABS. Provide approved plans.
46 CFR 31.10-25
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2021
Resolved 11 May 2021
Resolution: received ABS approvals from [name withheld], all sat.
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 29 April 2021
Resolved
Each tank shall be fitted with a liquid level gaging device of approved design that indicated maximum level tank may be filled. Vessel has Bergen System installed for cargo tank high level indication and alarm. System was disconnected and not able to be tested during inspection. Re-connect system and have tested in presence of Marine Inspector.
46 CFR 38.10-20(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2021
Resolved 17 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
Each item of equipment required under subpart J to be explosion proof under the classification system of NEC 2002 must be approved as meeting UL 1203. Vessel's hazardous location plan states that all electrical equipment within the hazardous zone shall be Class I Div I and be explosion proof. Glands attached to the power inlet of the Bergen display panel and light junction box are not Class I Div I. Replace with correct glands or move equipment out of hazardous location IAW plan.
46 CFR 111.105-5
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2021
Resolved 17 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
Each item of equipment required under subpart J to be explosion proof under the classification system of NEC 2002 must be approved as meeting UL 1203. Vessel's crew installed docking lights on the forward part of the vessel, port and stbd side. Lights do not meet Class I Div I standards. Replace lights with proper equipment or move them out of the hazardous zone IAW plan.
46 CFR 111.105-5
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2021
Resolved 17 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
Where cargo pump shafts pierce gas-tight bulkheads, stuffing boxes with readily accessible gas-tight glands shall be provided. Vessel's gas-tight bulkhead (forward bulkhead for machinery space) was not gas-tight at inspection. Vessel is waiting for a replacement pump shaft coupling to be able to re-install gas-tight coupling. Install required parts and prove gas-tight to attending Marine Inspector.
46 CFR 32.50-1
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2021
Resolved 17 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
Hazardous location equipment must be approved as suitable for use in the specific hazardous atmosphere in which it is installed. Vessel's crew installed tachometer on gas-tight bulkhead that is not Class I Div I equipment. Remove from hazardous zone.
46 CFR 111.105-5
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2021
Resolved 17 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
Hazardous location equipment must be approved as suitable for use in the specific hazardous atmosphere in which it is installed. Talk back station on gas-tight bulkhead has badly worn wires. Renew wires and maintain Class I Div I enclosure.
46 CFR 111.105-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2021
Resolved 17 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 April 2021
Resolved
At each inspection for certification and periodic inspection the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation. CUMMINS conducted tests on generators and vessel was supposed to provide report showing all shutdowns and test. Provide report to USCG.
46 CFR 61.20-3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 17 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 April 2021
Resolved
Each nonrising-stem valve, lever-operated valve, or other valve where, because of design, the position of the disc or closure mechanism is not obvious must be fitted with an indicator to show whether the valve is opened or closed. Several valves on deck were missing their open/close indicators, replace indicators on the following valves: #1 cargo Suction, #2 STBD ballast, #2 cargo suction, #4 port cargo suction, #4 STBD cargo suction, and #5 port ballast.
46 CFR 56.20-9(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 17 May 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2021
Resolved
Each vessel must carry lifebuoys approved under series 160.150. Several of the lifebuoys needed to be re-stenciled and some had missing retro tape. Correct the lifebuoys as follows: re-stencil forward lifebuoy, replace lifebuoy on STBD side amidships, re-stencil and put retro tap on lifebuoy port side amidships.
46 CFR 199.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 17 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
Electrical installations must ensure protection of passengers, crew and other persons from electrical hazards. Deck lighting on top of machinery space, STBD side was full of water. Perform maintenance to remove water and prevent water intrusion in the future.
46 CFR 111.101-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 17 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2021
Resolved
If twist-on type of connectors are used, the connections must be made within an enclosure and the insulated cap of the connector must be secured to prevent loosening due to vibration. Wire nuts were used on hot start wiring for STBD generator and diesel tank high level alarm in the machinery space. Remove wire nuts and make splices IAW section 25.11 of IEEE 45-2002.
46 CFR 111.60-17
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 17 May 2021
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 April 2019
Resolved
Make repairs to damaged hull plating, leaking aft keel coolers, and internal structural members as noted in Fincantieri-Bay Shipbuilding Barge Endeavour inspection survey’s dated 4/29/2019. All repairs shall be verified and to the satisfaction of attending CG MI prior to vessels refloating.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2019
Resolved 7 May 2019
Resolution: All repairs completed as required.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 9 May 2017
Resolved
Prove proper operation of overfill and high level alarms.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Resolved 10 May 2017
Resolution: tested all high level and overfill alarms
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 May 2017
Resolved
Refill CO2 Bottles in E/R for TFH
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 9 May 2017
Resolved 10 May 2017
Resolution: Refilled CO2 Bottles
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 9 May 2017
Resolved
Find and repair ground on electrical distribution system
Condition: Damaged By Earlier Event
Action required: 703 - Prior to bunkering operations
Due 9 May 2017
Resolved 10 May 2017
Resolution: Ground was fixed when CO2 bottles were filled and system reset.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 12 May 2016
Resolved
Auxiliary prime mover/generator removed from vessel for overhaul. Demonstrate proper operation to satisfaction of Marine Inspector. 46 CFR 111.12-1
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 27 May 2016
Resolution: Primary Generator overhaul complete, verified proper operation of generator.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 18 February 2015
Resolved
Repair high level indicating devices on Port side #1 and Starboard side #2 tank to the satisfaction of the Marine Insoector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2015
Resolution: Alarms were removed from tank, cleaned, and re-tested on the same day of the inspection to the satisfaction of the marine inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 18 February 2015
Resolved
Test transfer pipe system at 1.5 MAWP to satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2015
Resolved 5 May 2015
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 13 February 2015
Resolved
Fire suppression system for Thermal Fluid Heater space is discharged. Repair and re-charge fire suppression system in accordance with approved plans and manufacturer's instructions to the satisfaction of the Officer In Charge of Marine Inspections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2015
Resolution: Fire suppression system was recharged by Reliable Fire Equipment Technician and verified to be installed in accordance with approved plans and manufacturer’s instructions.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 January 2012
Resolved
Make repairs to fractured welds in the #3 P & S, #4 Port Ballast Water Tanks as noted by ABS Surveyor on January 12th, 2012. Damage at Web Frame to Cargo Hold connection; in #3 Starboard Ballast Tank 1-fractured weld, #3 Port Ballast Tank 2-fractured welds, & #4 Port Ballast Tank 4-fractured welds. Repairs shall be to the satisfaction of attending ABS Surveyor or USCG MI iaw 46 CFR 42.09-45(a)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 21 February 2012
Resolution: Repairs have been made, completed, and verified by ABS and USCG.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 13 January 2012
Resolved
Make Modification and permanent repairs to eliminate reoccurring cracking of weldment in effected Ballast Tanks. Modifications & Repairs shall be per approved drawings & to the satisfaction of attending ABS Surveyor or attending USCG Marine Inspector. Repairs shall be completed on or before 1 June 2012 iaw 46 CFR 42.09-45(a)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 21 February 2012
Resolution: Repairs have been made, completed, and verified by ABS and USCG.
Construction/Loadline › Hull › Weld
Issued 13 December 2011
Resolved
Determine root cause of repetitive fracturing of welds at web frame to cargo tank connection and cargo tank platting fractures and submit design plans to the Marine Safety Center for approval.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 February 2012
Resolved 11 June 2012