Records from 2016 to 2025. Most recent: inspection, 11 December 2025.
Inspection history · 25
11 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8282286
19 September 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8305556
15 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8239596
10 September 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7999264
5 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7847481
11 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7806599
16 June 2023
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7710343
8 June 2023
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7709703
30 January 2023
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7628950
28 January 2023
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7630258
9 December 2021
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7366326
18 November 2021
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7340004
12 October 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7331306
10 September 2020
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7055451
15 July 2020
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6928505
18 March 2020
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6928579
18 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6903283
19 February 2019
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6589141
28 February 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6363336
7 February 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6351228
7 February 2018
In-Service Inspection · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6351233
13 March 2017
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6095675
6 April 2016
Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5848531
14 March 2016
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5832929
7 January 2016
COI Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5792685
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 June 2023
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers. When tested, the starboard bilge pump failed to operate during the COI inspection. 46CFR182.520 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 21 June 2023
Resolution: Stbd bilge pump was replaced and operated satisfacty.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 June 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A second power pump is an acceptable alternative to a hand pump if it is supplied by a source of power independent of the first power bilge pump. Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Both installed bilge pumps are missing the operating light at the navigation station. 46CFR182.520 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 22 June 2023
Resolution: Provided satisfactory evidence of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2023
Resolved
An adult life jacket must be provided for each person carried on board. MI observed four life jackets that were sun damaged and molded. 46CFR180.71(a)
Action required: 10 - Deficiency Rectified
Resolved 20 June 2023
Resolution: Four life jackets were replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2023
Resolved
Paint and flammable liquid lockers. Paint and flammable liquids lockers must be constructed of steel or equivalent material, or wholly lined with steel or equivalent material. Flammable liquids are being storage under the console where electrical wiring is present. 46CFR177.405 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 21 June 2023
Resolution: Flammible liquids were relocated and stowed in metal container.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 June 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the vessel must be equipped with and adult size lifejacket for each person authorized. The vessel must also be equipped with 10% children’s lifejackets. Attending MI’s noted that the lifejacket labeling for the children’s lifejackets didn’t match the on board required amount. Either update the signage or add one children’s life jacket. 46CFR176.808 (e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 21 June 2023
Resolution: Labeling was corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2023
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least thee 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in contrasting color on each bucket. Label all fire buckets as required. 46CRFR181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 21 June 2023
Resolution: Fire buckets were labeled as required.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2023
Resolved
Waste Receptacles. Unless other means are provided to ensure that potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Vessel is utilizing a plastic waste receptacle. 46CFR177.405 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 21 June 2023
Resolution: Recepticle was replaced with non-combustible.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 June 2023
Resolved
In systems and applications where flexible hoses are permitted to be clamped: double hose clamping is required where practicable. MI observed missing hose clamps on fuel hoses. 46CFR410(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2023
Resolved 22 June 2023
Resolution: Double hose clamps were installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 January 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designated limitations. Vessel experienced a loss of propulsion. Make proper repairs to outboard motors and demonstrate satisfactory sea trials in the presence of USCG Marine Inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2023
Resolution: Vessel repowered with new outboard motors. Conducted satisfactory sea trials.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2021
Resolved
Portable fire extinguisher gauge showed the bottle was no longer charged. The bottom of the bottle was badly corroded. Replace extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 18 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2021
Resolved
Lifebuoy is missing corrosion-resistant lanyard clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2021
Resolved 18 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2021
Resolved
Remove lifejacket lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 18 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 July 2020
Resolved
STBD fuel tank sending unit inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 10 September 2020
Resolution: Operator replaced STBD sending unit and fuel gauges for both port and starboard fuel tanks are now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2020
Resolved
30 adult life jackets torn and unservicable. Replace 30 Type 1 adult life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2020
Resolved 10 September 2020
Resolution: Operator provided 30 servicable lifejackets to replace all unservicable life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 July 2020
Resolved
02 extinguishers out of service and add 10B:C extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2020
Resolved 10 September 2020
Resolution: Operator had 3 fire extinguishers serviced including the addition of a 10 B:C extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020
Resolved
Port and Starboard fuel shut off handles are secured with plastic zip ties. Replace plastic zip ties with fire resistant metallic fittings.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2020
Resolved 10 September 2020
Resolution: Operator replaced port and starboard fuel tank shutoff valve plastic zip ties with metal cable ties.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2020
Resolved
Affix port fuel vent hose to vent cover.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2020
Resolved 10 September 2020
Resolution: Operator affuxed port fuel vent hose to vent cover.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 February 2018
Resolved
Stbd pontoon bilge high level alarm inoperative. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2018
Resolution: New alarm installed and tested SAT.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 March 2017
Resolved
Retain valid original copy of certificate of Documentation iaw 46CFR67.5.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2017
Resolved 31 March 2017
Resolution: Tonnage calculations found vessel to be 4 net tons voiding requirement of COD.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 13 March 2017
Resolved
Provide proper grounding wire for fuel tanks iaw 46CFR182.440(b)(4).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2017
Resolved 29 March 2017
Resolution: Vessel installed grounding wire on both fuel tanks.
Lifesaving › Lifebuoys › Serviceable
Issued 13 March 2017
Resolved
Replace ring life bouy iaw 46CFR180.70(c)(6).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 March 2017
Resolved 29 March 2017
Resolution: Installed new ring life bouy.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 March 2017
Resolved
Install proper labels for life preservers iaw 46CFR185.604(f)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 29 March 2017
Resolution: Installed PFD labels at storage areas.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 7 January 2016
Resolved
Mark adult lifejacket stowage location
Condition: Placed in Improper Service
Due 9 March 2016
Resolved 18 February 2016