MAURY USCG vessel records Sign in
← All vessels

YM SATURN

YM SATURN is a 2007 tank ship. The Coast Guard has recorded 6 inspections since 2008, most recently in June 2024, along with 1 deficiency and 1 operational control.

Records from 2008 to 2024. Most recent: inspection, 9 June 2024.

Built
2007
Last inspected
9 June 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9362138 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
956015
Flag
MALTA
—
Maury page id
psix-956015

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (2008–2024)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10917 - Convention (Subpart B), Gross Ton
10605 - Simplified, Gross Ton
5260 - Convention (Subpart B), Net Ton
15988 - Dead Weight, Ton
5261 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 6

9 June 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7930958
7 June 2024 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7930090
5 June 2014 ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4879977
30 May 2014 Ballast Water Examination · Administrative Inspection · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 4874170
28 June 2008 Loadline Exam · ILO-147 Exam · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS III Exam · COC-TVE Annual · STCW 95 Exam · Administrative Inspection · ISM Exam · MARPOL Annex V Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3250231
7 June 2008 Ballast Water Examination · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3229464

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 June 2024 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: the ignitability of combustible materials shall be restricted. PSCO observed 05 containers filled with lube oil sitting out in the oil purifier space. 74 SOLAS (04) II-2/4.1.3
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 June 2024
Resolution: PSCO observed crew move containers to a proper stowage location, deficiency resolved.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.