MAURY USCG vessel records Sign in
← All vessels

MARCHAND ELEVATOR

MARCHAND ELEVATOR is a 1968 offshore supply vessel. The Coast Guard has recorded 10 inspections since 1990, most recently in June 1992, along with 13 deficiencies.

Records from 1990 to 1992. Most recent: inspection, 11 June 1992.

Built
1968
Last inspected
11 June 1992
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTZ4443
Flag
UNITED STATES
—
Maury page id
psix-95617

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (1990–1992)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)60.7 ft × 24.0 ft × 4.7 ft
Registered tonnagegross 70 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJACK-UP BOAT BUILDERS,INC · CAERNARVON, LA, UNITED STATES · built 1968
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it70 - Regulatory (Subpart C or D), Gross Ton
56 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

11 June 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266628
14 November 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 666036
22 July 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1250643
3 July 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 939736
31 January 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927845
23 January 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905764
22 January 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901689
8 January 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905420
26 November 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 910180
17 July 1990 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211073

Deficiency record · 13

Documentation
Issued 31 January 1991 Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGHTON, D.D INBOARD AND OUTBOARD PROFILES, LEG STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRALIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 1 October 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 31 January 1991 Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER,WASHINGTON, D.C. FOR REVIEW AND APPROVAL._x001C_
Condition: Unknown
Due 1 October 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 31 January 1991 Resolved
SUBMIT AN OPERATION MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C., VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL THE U.S. COAST GUARD APPROVED MANUAL ISRECEIVED._x001C_
Condition: Unknown
Due 1 October 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 31 January 1991 Resolved
CALIBRATED MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO OCME NEW ORLEANS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 January 1991
Resolved 31 January 1991
Navigation
Issued 22 January 1991 Resolved
CLAIBRATE MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO [name withheld]._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Navigation
Issued 17 July 1990 Resolved
CALIBRATE MAGNETIC COMPASS AND SUBMIT DEVIATION TABLE TO [name withheld] 33 CFR 164.35 (C).
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990
Electrical
Issued 17 July 1990 Resolved
INSTALL GENERATOR AMPERS, VOLT AND CYCLE METERS. SEE 46 CFR 111.30-25.
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990
Electrical
Issued 17 July 1990 Resolved
RENEW ELECRICAL LIGHTS WITH UL APPROVED TYPE IN ENGINE ROOM, ACCOMODATION SPACES, AND BRIDGE. SEE 46 CFR 110.10-1(B)(5)(XXI)
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990
Construction/Loadline
Issued 17 July 1990 Resolved
CROP AND RENEW BOTTOM PLATING WHERE DOUBLERS ARE INSTALLED (APPROX 7 INSERTS REQUIRED). SEE NVIC 7-68.
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990
Documentation
Issued 17 July 1990 Resolved
SUBMIT THE FOLLOWING PLANS FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C.: INBOARD AND OUTBOARD PROFILES, LEG STRUCTURAL SUPPORT AND LEG STRENGTH CRITERIA, HYDRAULIC JACKING SYSTEM DETAILS INCLUDING ALARMS AND CONTROLS.
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990
Documentation
Issued 17 July 1990 Resolved
PROVIDE APPROVED PLANS AS REQUIRED BY ITEM 1 TO THE COGNIZANT OCMI.
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990
Documentation
Issued 17 July 1990 Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U.S. COAST GUARD MARINE SAFETY CENTER, WASHINGTON, D.C., VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL THE U.S. COAST GUARD APPROVED MANUAL ISRECEIVED.
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990
Documentation
Issued 17 July 1990 Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER,WASHINGTON, D.C. FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 17 July 1990
Resolved 17 July 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.