CHEM NICHOLAS is a 2007 tank ship. The Coast Guard has recorded 17 inspections since 2008, most recently in April 2020, along with 11 deficiencies and 5 operational controls.

Records from 2008 to 2020. Most recent: operational control imposed, 14 April 2020.

Built
2007
Last inspected
13 April 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9374416 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
956170
Flag
LIBERIA
—
Maury page id
psix-956170

Inspections, by type

…with no type recorded5
Years with a record 8 calendar years (2008–2020)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it24112 - Convention (Subpart B), Gross Ton
47850 - Displacement, Metric Ton
38396 - Dead Weight, Metric Ton
11118 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

13 April 2020 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6938672
29 March 2020 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6932880
13 November 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6579889
12 October 2018 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6558403
27 May 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6156907
27 May 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6156927
23 January 2017 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6071745
22 August 2014 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4962257
26 July 2012 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4388947
2 July 2012 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4360874
23 June 2012 COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4352822
6 September 2011 PII Safety Exam · COC-CHEM Annual · Deficiency Check · COE-Dockside · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4137180
16 November 2010 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3892321
16 June 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3238936
16 June 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3239432
11 June 2008 ISPS II Exam · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex II Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3233566
9 June 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3231823

Deficiency record · 11

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 April 2020 Resolved
A chemical tanker shall comply with requirements of the IBC code... Independent cargo tanks shall be Electronically bonded to the hull. All gasketed cargo pipe joints and hose connections shall be electronically bonded. PSCO observed multiple (ie. Annex I line, IG line ivo shore connection and P/V breaker) bonding connections missing, and several installed bonding connections were installed without using proper bonding straps. 74SOLAS(14) CH VII, Reg 10 (IBC Code, CH10.2) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2020
Resolved 16 April 2020
Resolution: Vessel supplied class report detailing correction of electrically grounded for joints and connections.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 14 April 2020 Resolved
A chemical tanker shall comply with requirements of the IBC code...Where electrical equipment is installed in hazardous locations it shall be to the satisfaction of the administration and certified by the relevant authorities for operation in the flammable atmosphere concerned, as indicated in column i in the table of CH 17. PSCO observed several missing and loose screws/bolts on multiple MARFLEX cargo pump electrical connection terminal boxes. As per manufacturer missing components on pump could compromise the pumps explosion proof seal. PSCO also observed 01 light fixture on deck, without proper seal. 74SOLAS(14) CH VII, Reg 10 (IBC Code, CH10.1.5) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2020
Resolved 16 April 2020
Resolution: Vessel provided class report with corrected electrical connections.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 April 2020 Resolved
All access openings in bulkheads shall be weathertight when closed. Port State Control Officer observed daylight shining through the top portion of the weathertight door leading from the steering gear room emergency escape route to the aft deck,rendering it not weathertight. PSCO also observed three crewmembers being needed to close and latch the door. ILLC/12.1 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 April 2020
Resolved 16 April 2020
Resolution: Vessel provided class report detailing replaced watertight seal and subsequent testing of replacement.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 October 2018 Resolved
Where cable which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. Packing glands installed incorrectly on ESDs with exposed wires present.
Action required: 60 - Rectify deficiencies prior to movement
Due 12 October 2018
Resolved 13 October 2018
Resolution: Received class report attesting to repairs made by vessel crew.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 October 2018 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Wire ties in forward half of ship deteriorated. Metal protective covering wasted on pump wires from pump motor to cableway.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 October 2018
Resolved 30 March 2020
Resolution: 13NOV18- recieved class report from RINA. extended due date until 09FEB18 as per RINA 30MAR20- received class report from RINA. Deficency cleared.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 26 July 2012 Resolved
0611 - Lifeboats - Lifeboat equipment shall consist of food rations kept in airtight packaging. 26 out of 28 required food rations were not in airtight packaging - 74 SOLAS 09 Con. III/31.1.6, LSA Code 4.4.8.12
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: The Captain notified the vessel agent to send a supply of valid food rations to the vessel. A confirmation and receipt of such action order was show to Coast Guard examiners.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 26 July 2012 Resolved
1910 - Cargo Record Book - Every ship to which MARPOL Annex II applies shall be provided with a cargo record book in the form specified in MARPOL Annex II. The vessel did not have a Cargo Record Book onboard - 73 MARPOL 06 Con. II/15.1
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Vessel presented confirmation that Cargo Record Book was being sent to the ship.
Lifesaving › Lifeboat › Stability
Issued 6 September 2011 Resolved
Vessel's free-fall lifeboat has a crack in the gel coat on the keel. Class to address the condition of the keel an integrity of the life boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2011
Resolution: Crew has made repairs to the gel coat. This office received a copy of the Class (RINA) report attesting to the condition of the repairs.
Operations/Management › Pollution › Report of Discharge
Issued 6 September 2011 Resolved
VGP inspection form for Dry-dock was not completed when vessel completed dry-dock in Aug '10
Due 6 September 2011
Resolved 6 September 2011
Resolution: Forms were filled in and filed in the ships documents. Master reminded to continue to document and submit required paperwork.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 16 June 2008 Resolved
Vessel experienced loss of power while transiting into the harbor. Make proper repairs and provide satisfactory attestation report from class society that includes the cause of failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2008
Resolution: Rcvd sat class report
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 16 June 2008 Resolved
Vessel experienced loss of propulsion while transiting into the harbor. Make proper repairs and provide satisfactory attestation report from class society that includes the cause of failure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2008
Resolution: Rcvd sat class report

Ownership record