MAURY USCG vessel records Sign in
← All vessels

PAULA MCCALL

PAULA MCCALL is a 2009 offshore supply vessel. The Coast Guard has recorded 12 inspections since 2009, most recently in August 2017, along with 26 deficiencies.

Records from 2009 to 2017. Most recent: inspection, 22 August 2017.

Built
2009
Last inspected
22 August 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9561435 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE8306
956833
Flag
UNITED STATES
368024000 (licence lapsed)
Maury page id
psix-956833

Inspections, by type

Years with a record 8 calendar years (2009–2017)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
496 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
148 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDE8306MMSI 368024000 · expired · compulsorily equipped · granted 10 April 2009, cancelled 15 June 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 12

22 August 2017 MTSA/ISPS Verification · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 6248308
10 August 2017 In-Service Inspection
Physical examination · Activities Europe · Activity 6235960
22 May 2017 Administrative Inspection
Administrative · Activities Europe · Activity 6152034
10 June 2016 Drydock Extension · MARPOL Annex I Examination · DAPI Audit · COI Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 5903035
5 February 2016 Deficiency Check
Physical examination · Activities Europe · Activity 5811947
28 July 2015 Annual Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 5198357
16 May 2014 Annual Inspection · MTSA Verification · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 4859946
5 June 2012 MARPOL Annex VI Survey · MARPOL Annex I Examination · MTSA/ISPS Verification · DAPI Audit · Annual Inspection
Physical examination · Activities Europe · Activity 4273488
26 July 2011 Administrative Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4094824
15 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4082741
29 October 2010 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3880123
15 April 2009 Plan Review "T" Boat
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3454589

Deficiency record · 26

Operations/Management › Vessel Activity › Other
Issued 4 September 2017 Resolved
Box Freezer was blocking the emergency escape from the main cabin space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 4 September 2017
Resolution: Discrepancy was corrected on the spot.
Operations/Management › Vessel Activity › Other
Issued 22 August 2017 Resolved
Hazmat stored in engine space and not stored in Hazmat locker.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 September 2017
Resolved 4 September 2017
Resolution: Discrepancy was corrected on the spot.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 May 2017 Resolved
Vessel is permitted to deviate from approved plans in order to temporarily remove seating on main deck and install medical equipment to include beds, cabinets, oxygen bottles and other required necessities. All equipment must be approved and installed in accordance with the applicable Title 46 Code of Federal Regulations
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 10 August 2017
Resolution: Vessel replaced all removed seating, pictures were sent by the master.
Operations/Management › Vessel Activity › Other
Issued 22 May 2017 Resolved
No offshore passengers may be carried other than those receiving medical care, in order to clear this limitation, the USCG must be contacted and be satisfied with the vessel’s compliance with the current approved plans. Only the USCG can clear this limitation.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 10 August 2017
Resolution: Vessel replaced all removed seating, pictures were sent by the master. Vessel may operate in accordance with its COI.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 7 July 2016 Resolved
Certificate was found to be expired, vessel shall not sail with out a valid certificate or with out a plan approved by the FCC.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2016
Resolved 7 July 2016
Resolution: Vessel was given an extenstion of the certificate by the FCC
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 July 2016 Resolved
Display prioper operation of the vessel oiily water separator
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 24 August 2016
Resolution: Resolved in MISLE Activity 5924306
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 7 July 2016 Resolved
Repair ground detector on main electrical switchboard in engine room.
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 24 August 2016
Resolution: Resolved in MISLE Activity 5924306
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 7 July 2016 Resolved
Starboard rudder angle indicator on the bridge was not reading the correct angle, demonstrate proper operation of the rudder angle indicator.
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 24 August 2016
Resolution: Resolved in MISLE Activity 5924306
Lifesaving › Inflatable Liferafts › Float Free
Issued 7 July 2016 Resolved
Liferafts were found to be installed incorrectly
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 7 July 2016
Resolution: Liferafts were verified to be installed correctly
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 27 August 2015 Resolved
Provide two lifebuoys with self-activating smoke signals capable of quick release from the Bridge.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 January 2016
Resolved 5 February 2016
Lifesaving › Line-Throwing Appliances › Lines
Issued 27 August 2015 Resolved
Provide one (1) line-throwing appliance.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 20 September 2015
Construction/Loadline › Markings › Load Line Mark
Issued 27 August 2015 Resolved
Place deck line marks on the vessel in accordance with the International LoadLine certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 4 September 2015
Communications › Radio Communications › EPIRB
Issued 16 May 2014 Resolved
EPIRB shall be stowed in float free bracket. During exam, the bracket was found to be damaged. Replace EPIRB bracket. CG835 extended 6/18/2014 due to shipping of EPIRB bracket.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 July 2014
Resolved 3 December 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2014 Resolved
Provide stern/anchor light. Vessal may not anchor outside daylight hours until provided.
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 10 June 2014
Engineering › Steering Gear System › Pump
Issued 16 May 2014 Resolved
The steering gear must be capable of moving the rudder from 35 degrees on one side to 30 degrees on the other side. During steering test, the vessel could only achieve 30 degrees on either side. Repair and demonstrate proper operation.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 June 2014
Resolved 18 June 2014
Resolution: Received report from master that rudder limit switches and rudder angle indicators adjusted and tested sat.
Documentation › Logs/Records › Logbook (official)
Issued 5 June 2012 Resolved
Submit fully completed official ships log book iaw 46CFR130.620 within 90 days
Action required: 705 - Other - as specified
Due 5 September 2012
Resolved 10 September 2012
Resolution: Official log book mail to OCMI.
Personnel › Training › Radar Observer
Issued 5 June 2012 Resolved
Provide copy of vessel captain's radar observer training certificate.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 2 July 2012
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 5 June 2012 Resolved
Conduct required annual review of SMPEP iaw 33CFR151.26 and provide approval letter proof of submission to the VRP desk iaw SMPEP approval letter.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 6 June 2012
Resolution: Receive confirmation email from vessel rep of submittal.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 June 2012 Resolved
Provide CG approved automation test procedured and proof of annual testing iaw 46 CFR 130.480 and vessels COI. Extended to 05AUG for procedures to be approved.
Action required: 705 - Other - as specified
Due 5 August 2012
Resolved 4 June 2013
Resolution: No PTSP on board def rewritten and included in AN 4584213
Communications › Radio Communications › VHF Radiotelephone
Issued 5 June 2012 Resolved
Provide radiotelephone station clock for GMDSS suite iaw 47 CFR 80.865. Extended to 05Sept to clear customs.
Action required: 705 - Other - as specified
Due 5 September 2012
Resolved 6 June 2013
Resolution: Clock installed
Lifesaving › Line-Throwing Appliances › Lines
Issued 5 June 2012 Resolved
Provide 1500 ft auxiliary line for impulse line throwing guns approval series 46 CFR 160.040. Extended to 05 Sept to clear customs.
Action required: 705 - Other - as specified
Due 5 September 2012
Resolved 11 September 2012
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 5 June 2012 Resolved
Provide oil transfer procedures iaw 33 CFR 155.720 and 750
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 5 June 2012
Resolution: CHENG found the procedures prior our departure from the vessel.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 5 June 2012 Resolved
Provide paint locker which is steel or wholly lined in steel iaw 46 CFR 127.220 by next dry-docking 28 June 2013.
Action required: 705 - Other - as specified
Due 28 June 2013
Resolved 6 July 2013
Resolution: Replaced.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 June 2012 Resolved
Conduct night abandon ship drill iaw 46 CFR 131.530(b)(9).
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 2 July 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 June 2012 Resolved
Install emergency lighting in order to read liferaft placards, launch and embarkation of the rescue boat and liferafts at water line in emergency lighting conditions iaw 46 CFR 131.530
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 2 July 2012
Documentation › Logs/Records › Drug Test Records
Issued 5 June 2012 Resolved
Sumbit completed DAPI audit provided to master.
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 6 June 2012
Resolution: Vessel rep provided completed documentation

Ownership record