Documentation record
Registered dimensions (L × B × D)53.0 ft × 18.0 ft × 10.0 ft
Registered tonnagegross 63 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2009
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMIAMI BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 13 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Simplified, Gross Ton
51 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
10 June 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8401299
23 September 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8239453
6 September 2025
Type not recorded
No type recorded · USCGC ROLLIN A. FRITCH (WPC 1119) · USCG East District (CGD-E) · Activity 8229970
23 June 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8165076
21 March 2024
Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7878965
3 October 2023
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7806469
5 July 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7733307
12 June 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7712730
21 June 2022
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7484106
10 September 2021
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7308866
26 July 2021
Type not recorded
No type recorded · USCGC MANATEE (WPB 87363) · USCG Southeast District (CGD-SE) · Activity 7270550
15 June 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7226287
19 June 2020
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6980822
5 September 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6803719
20 March 2019
DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6644996
5 June 2018
Annual Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6428883
10 October 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6298827
5 June 2017
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6165915
9 June 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5901834
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 23 June 2025
Resolved
Marine employers must ensure that data submitted by a consortium or other employer representative under paragraph (b)(3) of this section is correct. One of the captains licensing information was missing on the consortium enrollment letter.
46 CFR 16.500(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 24 June 2025
Resolution: Def resolved, vessel capt sent an updated picture of the drug testing consortium with the required members licensed information included.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 23 June 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel is missing emergency instructions to be posted at the operating station.
46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 2 July 2025
Resolution: Posted emergency instructions.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 June 2025
Resolved
When using SDC techniques, ship stations must use maritime mobile service identities (MMSI) assigned by the FCC. Vessel radio did not have the MMSI entered.
47 CFR 80.103(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2025
Resolved 2 July 2025
Resolution: Programmed MMSI into new radio.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 March 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. The vessel's compass is not illuminated, and vessel's current COI does not limit them to daytime operations only. Vessel is limited to daytime operation only until vessel's compass can be illuminated.
46 CFR 184.402
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 March 2024
Resolution: MI received evidence of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 June 2023
Resolved
Lifefloat weak link is the wrong type. Vessel has a 21 or more link but needs a 15 or less. Restricted to 3 NM until new link is installed.
Action required: 705 - Other - as specified
Resolved 14 June 2023
Resolution: New weak link installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2023
Resolved
STBD side engine exhaust is leaking water at aft bulkhead connection. Replace clamps.
Action required: 705 - Other - as specified
Resolved 14 June 2023
Resolution: All clamps were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2023
Resolved
STBD Side engine has a coolant leak on turbo cooling line. Replaced gasket
Action required: 705 - Other - as specified
Resolved 14 June 2023
Resolution: Replaced gasket.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2023
Resolved
Clamps on fuel tank hoses are rotted. Replace with new.
Action required: 705 - Other - as specified
Resolved 14 June 2023
Resolution: All Clamps were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2021
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel lines. Emergency fuel shut off port side not completely closing. Inspect and adjust to ensure full travel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 16 June 2021
Resolution: Fuel valve handles were modified to allow full closure of the valves.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 June 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew from electrical hazards. Engine room wiring run into the bilge. Ensure electrical cables are run as high as possible out of the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 16 June 2021
Resolution: Wires were removed from the bilge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 June 2021
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. Forward engine room bullhead wire run needs to be made watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 16 June 2021
Resolution: Wire run was sealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 June 2017
Resolved
Remove or cap dead-end wires on bridge and forward void space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 5 June 2017
Resolution: All dead-end wiring was caped.
Lifesaving › Lifebuoys › Serviceable
Issued 14 June 2016
Resolved
Replace ring buoy with 24 inch ring buoy(worn with foam core exposed and retro worn) 46CFR180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 15 June 2016
Resolution: Vessel cleared last remaining def by adding a brand new 24" ring buoy to the vessel.
Lifesaving › Buoyant Apparatus › Marking
Issued 14 June 2016
Resolved
Life float paddles are not properly marked. 46CFR185.604
Condition: Improper/Lack of Maintenance
Due 21 June 2016
Resolved 14 June 2016
Resolution: Corrected on the spot by remarking the paddles.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 June 2016
Resolved
Port nav light inop. 46CFR183.420
Condition: Improper/Lack of Maintenance
Due 21 June 2016
Resolved 14 June 2016
Resolution: Nav light bulb replaced.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 14 June 2016
Resolved
Waste management plan not onboard. 33CFR151.57
Condition: Improper/Lack of Maintenance
Due 21 June 2016
Resolved 14 June 2016
Resolution: Waste management was provided.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 14 June 2016
Resolved
Fuel shut off valve not marked. 46CFR185.608
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 14 June 2016
Resolution: Fuel shut-off valve was marked.
Lifesaving › Hand Flares › Quantity
Issued 14 June 2016
Resolved
Provide 01 distress flare. 46CFR180.68
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2016
Resolved 14 June 2016
Resolution: Missing distress signal was provided.