CARIBE NAVIGATOR

CARIBE NAVIGATOR is a 1995 freight ship. The Coast Guard has recorded 43 inspections since 2008, most recently in August 2026, along with 21 deficiencies and 2 operational controls.

Records from 2008 to 2026. Most recent: inspection, 14 August 2026.

Built
1995
Last inspected
14 August 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9116204 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
957720
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-957720

Inspections, by type

…with no type recorded7
Years with a record 17 calendar years (2008–2026)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2996 - Convention (Subpart B), Gross Ton
2996 - Simplified, Gross Ton
1398 - Simplified, Net Ton
1398 - Convention (Subpart B), Net Ton
4602 - Dead Weight, Ton
6565 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

14 August 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8463974
16 April 2026 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8351238
11 February 2026 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8309154
8 August 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8205206
31 January 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8073589
17 January 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8063968
27 June 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7933261
3 June 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7925986
11 December 2023 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7835906
13 July 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7741286
22 April 2023 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7673050
3 April 2023 Administrative Inspection · Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7661534
12 September 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7556737
29 May 2022 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7464492
3 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7443233
11 March 2022 PSC B · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7410543
8 September 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7306670
8 March 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7151811
28 February 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7147723
31 August 2020 PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7046085
25 February 2020 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6915231
23 December 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6878219
20 August 2019 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6788516
5 February 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6620237
1 August 2018 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6497834
24 January 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6342592
18 July 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6211749
18 January 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6072527
1 August 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5959547
27 July 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5954864
14 July 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5947086
13 July 2016 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5940491
12 July 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5937991
14 January 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5797182
22 May 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4865352
14 June 2012 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4343686
26 January 2012 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4231546
20 January 2011 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3929302
20 January 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3930417
9 September 2010 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3845994
9 January 2009 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3390994
16 July 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3269787
27 June 2008 Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3249834

Deficiency record · 21

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 February 2026 Resolved
A SECOND SOURCE OF ENERGY SHALL BE PROVIDED FOR AN ADDITIONAL 03 STARTS. PSCO'S OBSERVED THE SECOND EMERGENCY BATTERY FOR THE EMERGENCY DIESEL GENERATOR WAS NOT OPERATIONAL. 74SOLAS 04 CONS. 11-1/44.2 17(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2026
Resolved 11 February 2026
Resolution: VESSEL REPLACED BATTERY ON THE SPOT, AND WAS ABLE TO PASS LOAD TEST AND START 03 TIMES.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 17 January 2025 Resolved
An engineers alarm shall be... And shall be clearly audible in the engineers accomodation. Engineers alarm was not audible in [name withheld] accomodation 74 SOLAS (04) II-1/38 Code 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2025
Resolved 3 February 2025
Resolution: 31JAN25: Received documentation from BV for the repairs for the engineer's alarm 31JAN25: Received documentation from BV for the repairs for the engineer's alarm. The engineer's alarm is now audible in the Chiefs engineer's and 2nd engineer's cabins.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 22 April 2023 Resolved
An alarm system shall be provided indicating any fault requiring attention and shall: Activate an audible and visual alarm on the navigation bridge for any situation which requires action by or attention of the officer on watch. PSCOs discovered the alarm system on the bridge for the engineers alarm inoperable. All other engineer alarm repeaters throughout the vessel worked. 74SOLAS(97 CONS) II-1/51.1.3 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2023
Resolved 3 June 2024
Resolution: Vessel survey report see documents tab for detail.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 3 April 2023 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that: any non-conformity is reported, with its possible cause, if known. PSCO's observed a hole due to excessive corrosion on the port side bulkhead of cargo hold number 2 on frame #45, above the waterline. It was determined that the master was aware of the damage but failed to report the non-conformity in accordance with the ship's Safety Management System. An ISM audit of the vessel SMS is required before departure. 74 SOLAS (2020) Cons. IX/3.1 ISM Code Part A. 10.1
Action required: 30 - Ship detained
Resolved 8 April 2023
Resolution: Sector Miami recieved reports from both Class and Flag attesting to the completion of an ISM Audit.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 3 April 2023 Resolved
In the circumstances given in paragraph (b) or where a certificate has expired or ceased to be valid, the officer carrying out the control shall take steps to ensure that the ship shall not sail until it can proceed to sea or leave the port for the purpose of proceeding to the appropriate repair yard without danger to the ship or persons on board. PSCO's observed a hole due to excessive corrosion on the port side bulkhead of cargo hold number 2 on frame #45, above the waterline. Because the condition of the cargo hold is not maintained to the provisions of the present regulations as provided in the SOLAS Cargo Ship Safety construction certificate, it ceases to be valid. 74 SOLAS 20 I/19(c)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 April 2023
Resolution: Sector Miami received reports from both class and the flag state attesting to the repair of the hole.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 14 March 2022 Resolved
Arrangements shall be made to ensure immediate availability of a supply of water from the fire main at the required pressure either by permanent pressurization or by suitability placed remote arrangements for the fire pumps. PSCO's observed that the emergency fire pump was not capable to start remotely, only local. Vessel is required to meet the requirements of Reg. 19.3 per the requirements of exisiting ships, II-2/2.4. 74SOLAS (2020 Cons) Reg. II-2/19.3.1.1 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 3 May 2022
Resolution: RO verified the install and SAT operational test of the remote starting arrangements for the emergency fire pump
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 August 2020 Resolved
Detectors and manually operated call points shall be grouped into sections. The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. Smoke detectors 1-3 and 1-6 located on deck 1 of engine room did not initiate a visual or audible fire signal at the control panel and indicating units. 74SOLAS (97 Consolidated) II-2/13.1.4
Action required: 10 - Deficiency Rectified
Due 31 August 2020
Resolved 31 August 2020
Resolution: Vessel electrician came aboard and rectified the deficiency. Witnessed satisfactory test in the engine room and on the bridge alarm panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 August 2020 Resolved
Every lifebuoy shall... If it is intended to operate the quick-release arrangement provided for the self-activated smoke signals and self-igniting lights, have a mass sufficient to operate the quick-release arrangement or 4 kg, whichever is greater. Lifebuoys located on both bridge wings were not of the correct weight. PSCO observed the lifebuoys of only 2kg. 74SOLAS (97 Cons.) III/31.7
Action required: 10 - Deficiency Rectified
Due 31 August 2020
Resolved 31 August 2020
Resolution: Vessel had correct lifebuoys located in storage, however they did not have the proper labels or the retro-reflective tape. Vessel crew had the lifebuoys correctly stickered/taped and placed on the bridge wings before port state team departure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 August 2019 Resolved
The means for securing and monitoring weather tightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. PSCO observed a port side forward weather deck emergency escape hatch was unable to be properly secured to ensure weather tightness. ICLL 66/68 Annex I/ Reg. 16.4
Action required: 10 - Deficiency Rectified
Due 20 August 2019
Resolved 20 August 2019
Resolution: Crew adjusted the dawgs and the strut on the hatch, and demonstrated to the PSCO that the hatch is now weather tight.
Documentation › Markings/Placards › Garbage Placard
Issued 24 January 2018 Resolved
2120 - GARBAGE - EVERY SHIP 12M OR MORE SHALL DISPLAY PLACARDS WHICH NOTIFY OF DISCHARGE REQUIREMENTS OF REGULATIONS 3,4, 5 AND 6 OF THIS ANNEXX. PLACARDS DISPLAYED ARE NOT MATCHING THE REGULATIONS. MARPOL ANNEX VI REG 10.1 50ac
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 25 January 2018
Resolution: Class report received stating placards would be updated and SMS changes for the vessel handling garbage would follow MARPOL and not dump uncomminuted garbage overboard in special areas.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 24 January 2018 Resolved
2120 - GARBAGE - EVERY SHIP 100 GROSSTONS AND ABOVE SHALL CARRY A GARBAGE MANAGEMENT PLAN WHICH THE CREW FOLLOW. PLAN ONBOARD DOES NOT ADDRESS THE COMMUNUTION AND GRINDING OF FOOD WASTE WHEN OPERATING INSIDE AND OUTSIDE SPECIAL AREAS. MARPOL ANNEX VI REGULATION 10.2 50ac
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 25 January 2018
Resolution: Class report received stating placards would be updated and SMS changes for the vessel handling garbage would follow MARPOL and not dump uncomminuted garbage overboard in special areas.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 18 January 2017 Resolved
0690 - Line Throwing Apparatus - A line throwing appliance complying with regulation 49 shall be provided. All 4 projectiles for line throwing appliances expired on NOV2016. 74SOLAS (1997 con.) CH III/17
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2017
Resolution: Received report from vessel class attesting to purchase and delivery to vessel of 4 new line throwing appliances.
Engineering › Freshwater System (piston cooling) › Pump
Issued 12 July 2016 Resolved
1499 - Other (Prop. & Aux. Machinery) - Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperable, the sources of water pressure. The main engine cooling pumps #1 & #2 have considerable leakage. 16a
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 28 July 2016
Resolution: Class report received, def cleared.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 12 July 2016 Resolved
0950 - Electric Equipment - When neccessary, nonconducting mats or gratings shall be provided at the front and rear of the switchboard. The main & emergency switchboard is missing sections of non conducting matting. 16a
Action required: 705 - Other - as specified
Due 26 July 2016
Resolved 14 July 2016
Resolution: PSCO observed matting in place on 14Jul16, def cleared.
Electrical › Electric Generation Source (emergency) › Generator
Issued 14 January 2016 Resolved
Generator's fuel filter was clogged and not providing enough fuel to sutain the generator to operate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2016
Resolved 14 January 2016
Resolution: Vessel replaced the filters and tested generator with satisfactory results.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Master
Issued 14 June 2012 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2012
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 January 2012 Resolved
0710 Doors required to be self-closing shall not be fitted with hold-back hooks. According to fire plan, the A-0 door to the galley is required to be self-closing with a magnetic door holder- this door is fitted with a hold-back and does not have the magnetic holding device required by the ship's fire plan. 74 SOLAS (97) II-2/47.2. 50b
Action required: 705 - Other - as specified
Due 26 February 2012
Resolved 6 February 2012
Resolution: Received report from class that door was re-classified as a door without a required magnetic holding device.
Construction/Loadline › Structures › Air Pipe
Issued 26 January 2012 Resolved
1275 Where air pipes to ballast and other tanks extend above the freeboard or superstructure deck, the exposed parts of pipes shall be of substantial construction. Vent pipe from ballast tank (port side, midship) has significant detioration on its top section and the metal is wasted through in a few spots. ICLL '66 I/20.1
Action required: 705 - Other - as specified
Due 9 February 2012
Resolved 6 February 2012
Resolution: Received a report of class attesting that new ballast tank vents were fitted. //s// [name withheld]
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 20 January 2011 Resolved
MARPOL ANNEX I REG. 15.A.2: Any discharge into the sea of oil or oily mixtures shall be prohibited. Vessel is discharging an oily sheen around controllable pitch propeller and rudder.
Action required: 705 - Other - as specified
Resolved 31 January 2011
Resolution: Received Class report attesting satisfactory repairs to #2 & #3 Blades.
Lifesaving › Rescue Boat › Hull (inflated)
Issued 20 January 2011 Resolved
SOLAS 74 ('09 CONS) III/20.2: All life-saving appliances shall be in working order and ready for immediate use. Port side inflatable pontoon on vessel's rescue boat was found flat.
Due 20 January 2011
Resolved 20 January 2011
Resolution: Corrected on the spot: Pontoon was inflated and did not appear to be leaking. After a review of ships service logs regarding the rescue boat, the captain was advised to take corrective action if any additional problems are observed.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 20 January 2011 Resolved
SOLAS 74 ('09 CONS) II-2/9.4.2.1: Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gas tight and self closing. (3) Three A class fire doors have been modified with a hold back bracket in the engine space.
Action required: 705 - Other - as specified
Due 19 February 2011
Resolved 28 April 2011
Resolution: Vessel removed brackets for holdbacks in all three doors.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.