Records from 2016 to 2026. Most recent: inspection, 29 July 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 19
29 July 2026
Type not recorded
No type recorded · USCGC OLIVIA HOOKER (WPC 1161) · USCG Heartland District (CGD-H) · Activity 8450551
30 April 2026
Administrative Inspection · Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8321174
20 May 2025
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8126896
14 May 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7912495
24 April 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7900927
16 April 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7896434
23 May 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7712686
16 June 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7478986
1 December 2021
Administrative Inspection · Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7360271
26 March 2021
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7162547
3 February 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7135115
9 March 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6923056
1 May 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6674072
26 March 2019
Hull Examination · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6649722
23 February 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6360645
7 August 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6233544
19 May 2017
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6150415
25 February 2017
Internal Structural Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6094530
4 March 2016
DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5826900
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 April 2024
Resolved
Vessel's COI has been revoked due to being past dry dock date
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2024
Resolution: COI inspection complete
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 May 2023
Resolved
Crew members were not listed as being part of the random drug testing through vessel's drug consortium.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2023
Resolved 26 June 2023
Resolution: Received satisfactory documentary evidence; vsl cleared.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 March 2021
Resolved
Fixed fire detection system is not securing the starboard diesel engine when tested as required. Show proper operation of the fire detection system and provide service report.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2021
Resolved 26 March 2021
Resolution: Fixed fire detection system repaired, burn wire from system being in override since last Coast Guard inspection. Additionally, one of the relays in the system was nonoperational. Service report is in documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2021
Resolved
Life jackets have worn reflective tape. Renew life jacket reflective tape or replace life jacket.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2021
Resolved 26 March 2021
Resolution: Replaced worn reflective tape with SOLAS grade reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 March 2021
Resolved
Life floats have worn reflective tape and grab lines show signs of dry rotting. Replace tape and grab lines or replace floats in kind.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 March 2021
Resolved 26 March 2021
Resolution: Life floats were replaced in kind.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 March 2021
Resolved
DAPI Letter with crewmembers enrolled is not available. Provide list with crewmembers enrolled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 1 April 2021
Resolution: Documentary evidence with letter sent from gulf south resources verifying enrollment.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 March 2021
Resolved
Alcohol strips are expired. Provide alcohol strips that are not expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: Documentary evidence submitted with new alcohol test strips.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 February 2021
Resolved
Vessel must undergo a drydock examination and internal structural examination at least once every two years. Vessel did not complete drydock and internal structural examination by the date listed on the COI, 31JAN21. Vessel shall not operate until a complete examination has been conducted by a CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2021
Resolution: Vessel completed drydock examination satisfactorily.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 May 2019
Resolved
Coast Pilot and Light list are out of date. Provide updated publications.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2019
Resolution: Received picture of publications
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 May 2019
Resolved
EPIRB not currently operational. Provide functional EPIRB with applicable NOAA registration. Without operational EPIRB vessel is restricted to 3NM from shore.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 May 2019
Resolution: Received picture of EPIRB and registration
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 March 2019
Resolved
Vessel drydock date has passed. Vessel must complete a hull examination once every two years prior to the exam drop-dead date of 31JAN of the exam year as listed on the COI. Vessel shall not carry passengers until the hull examination is completed. Vessel may transit to Nelson's Boatyard for haul-out.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 11 April 2018
Resolved
Gauges to provide L/O pressure must be provided for both main engines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 23 May 2018
Resolution: Gauges work as designed
Electrical › Electric Supply System (service) › Cable
Issued 11 April 2018
Resolved
Install proper cable gland for the live well motor in the E/R
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 23 May 2018
Resolution: Cable gland installed
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2018
Resolved
VHF-DSC radios must have GPS capabilities or be connected to an electronic position fixing device.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2018
Resolved 23 May 2018
Resolution: Installed new radio; ALL SAT
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 June 2017
Resolved
Conduct drills and log accordingly, IAW 46CFR185.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 7 August 2017
Resolution: Drills and logs are now being logged accordingly.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 June 2017
Resolved
Test and log EPIRB IAW 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 7 August 2017
Resolution: EPIRB is now being tested and logged monthly.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 June 2017
Resolved
Mount EPIRB IAW 46 CFR 185.604
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 7 August 2017
Resolution: EPIRB is mounted.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 June 2017
Resolved
Attach one water light to life float IAW 46 CFR 185.604
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 7 August 2017
Resolution: Waterlight is attached to the body of the lifefloat.
Lifesaving › Lifefloat › Paddle
Issued 22 June 2017
Resolved
Label life float paddles with vessels name IAW 46 CFR 185.604
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 7 August 2017
Resolution: Lifefloat paddles are labeled and lashed to lifefloats.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 June 2017
Resolved
Relabel life jackets stowage IAW 46 CFR 180.78
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 7 August 2017
Resolution: Life jacket stowage has been properly relabeled.
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 22 June 2017
Resolved
Make anchor light operable IAW 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 7 August 2017
Resolution: Anchor light is operable.
Fire Fighting › Structural - A Class Divisions › Windows
Issued 4 May 2017
Resolved
Repair window in starboard parlor IAW 46 CFR 176.800
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 23 May 2018
Resolution: Resolved
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 March 2016
Resolved
FCC Safety Radio Certificate expired. Provide current document IAW 46 CFR 184.502.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 18 April 2016
Resolution: New Safety Radio cert provided.
Documentation › Certificates/Documents › FCC SSL
Issued 28 March 2016
Resolved
Copy of FCC Station License onboard. Provide original IAW 46 CFR 184.502.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 18 April 2016
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Generator (propulsion-electric) › Circuit Breaker (overload/over current protection)
Issued 28 March 2016
Resolved
GENs not labeled as DERATED. Mark as DERATED to 80% IAW 46 CFR 183.320.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 19 April 2016
Resolution: Derated stickers on generator.
Stability › Watertight Integrity › General
Issued 28 March 2016
Resolved
Worn gasket on laz hatch cover. Replace IAW 46 CFR 171.124.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 18 April 2016
Resolution: Replaced gasket.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 28 March 2016
Resolved
Emergency hatch not labeled. Mark outside of hatch "EMERGENCY EXIT, KEEP CLEAR" IAW 46 CFR 185.606.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 18 April 2016
Resolution: Hatch properly labeled.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 28 March 2016
Resolved
STBD RPM guage inoperable. Make operable IAW 46 CFR 182.410.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 18 April 2016
Resolution: Verified proper operation of RPM gauges.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 28 March 2016
Resolved
No evidence of EAP trng onboard. Provide documentation IAW 46 CFR 16.401.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 19 April 2016
Resolution: Certificate of training provided.