← All vessels
KIRBY 11357
Tank Barge · Barge class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named KIRBY 11357 · ST. TAMMANY PARISH DEVELOPMENT DISTRICT operator of record, 2023
KIRBY 11357 is a 2008 tank barge. The Coast Guard has recorded 16 inspections since 2008, most recently in August 2025, along with 3 deficiencies and 1 casualty investigation in 2011.
Records from 2008 to 2025. Most recent: inspection, 20 August 2025.
- Built
- 2008
- Last inspected
- 20 August 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2011
Identity
1215573
958876
Flag
UNITED STATES
—
Maury page id
psix-958876
Inspections, by type
…with no type recorded1
Years with a record
13 calendar years (2008–2025)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.6 ft
Registered tonnagegross 740 / net 740
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2008
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it740 - Simplified, Gross Ton
740 - Simplified, Net Ton
740 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
20 August 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 8227808
8 January 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8060243
23 October 2023
Examination of Repairs · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7806277
10 February 2022
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7394889
27 January 2021
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7131705
14 February 2020
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6909407
30 January 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6899617
11 October 2018
Internal Structural Exam · COI Inspection · Examination of Repairs · Drydock Exam · Cargo Tank Internal · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6551903
29 January 2018
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6342836
30 January 2017
Deficiency Check · Administrative Inspection · MARPOL Annex VI Survey · Periodic Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6079715
16 March 2016
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 5836233
11 March 2015
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5098400
12 December 2013
Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4766300
8 March 2012
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4257506
26 March 2010
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3703468
30 December 2008
Hull Examination · Internal Structural Exam · Cargo Tank Internal · Initial Certification · Initial Construction-Excluding Oversight · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3465231
Deficiency record · 3
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 30 January 2017
Resolved
Ensure the vessel has an approved response plan onboard (Response Plan Approval letter (17342) March 8, 2013)). The response plan that is on the vessel is the older expired version.
Electrical › Electric Supply System (service) › Cable
Issued 16 March 2016
Resolved
Issued CG835 for missing gasket, negating intrinsically safe seal, on high level/overfill alarm box in way of the #3 cargo tank. Barge is loaded with styrene and is authorized a one-time discharge. Alarm box is to be made intrinsically safe prior to next loading.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 March 2010
Resolved
Vessel was inspected and found not to have a certificate of inspection onboard. Vessel is instructed to place the COI onboard the vessel prior to conducting any cargo operations.
Casualty record · 1
30 March 2011Routine · role: Involved in a Marine Casualty · activity 3975603
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
FMT 1014 (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.