MAURY USCG vessel records Sign in
← All vessels

THETAGAS

THETAGAS is a 2008 tank ship. The Coast Guard has recorded 13 inspections since 2010, most recently in February 2026, along with 2 deficiencies and 2 operational controls.

Records from 2010 to 2026. Most recent: inspection, 23 February 2026.

Built
2008
Last inspected
23 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9368792 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
959379
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-959379

Inspections, by type

…with no type recorded2
Years with a record 9 calendar years (2010–2026)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10264 - Dead Weight, Metric Ton
15321 - Displacement, Metric Ton
9110 - Convention (Subpart B), Gross Ton
2734 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

23 February 2026 COC-GAS Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8311492
29 February 2024 Administrative Inspection · PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7872308
23 December 2021 Ballast Water Examination · Administrative Inspection · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7372053
4 September 2018 COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6524495
18 August 2017 ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6237627
18 August 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6327019
3 January 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5790007
26 December 2015 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5787269
10 February 2011 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3942665
3 February 2011 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3938322
12 January 2011 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3925571
28 December 2010 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3917130
23 December 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3915601

Deficiency record · 2

Communications › Audible Communications › Horn/Whistle
Issued 18 August 2017 Resolved
An audible and visual alarm system to give a warning on both sides of the airlock should be provided to indicate if more than one door is moved from the closed position. Compressor motor room airlock horn inoperable from inside motor room. 16C(93)3.6.3 10C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 18 August 2017
Resolution: Discrepancy Rectified
Construction/Loadline › Structures › Door
Issued 28 December 2010 Resolved
Airlock doors between a gas dangerous zone on deck and a gas safe space shall be self-closing. Airlock doors to motor room found to be non self closing. IGC Code Ch. 3.6.2
Action required: 705 - Other - as specified
Due 29 January 2011
Resolved 10 February 2011
Resolution: Received class report from attesting that the self closing device is in compliance.

Ownership record