Records from 2008 to 2017. Most recent: inspection, 26 April 2017.
Stability › Watertight Integrity › General
Issued 26 April 2017
No resolution recorded
VESSEL GRANTED A HULL EXAM DUE DATE EXTENSION ON 28APR2017; MUST COMPLETE A CREDIT HULL EXAM PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Construction/Loadline › Hull › Bottom Plating
Issued 30 March 2017
Resolved
Vessel shows signs of corrosion and metal deterioration where dissimilar metals are making contact. Ares of concern are the front wheel suspension and shaft penetrations. Disassemble equipment/parts and prep metal surfaces for visual examination.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 May 2017
Resolution: Thoroughly inspected sister vessel (Super duck 3 Activity # 6114531) for with chassis/suspension removed from the hull/structural beams. Based on the findings of super duck 3, cleared CG-825 requirements
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 9 June 2016
Resolved
Prove proper operation of propulsion engine after loss of propulsion.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 9 June 2016
Resolution: Deficiency resolved after satisfactory u/w sea trials.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 March 2016
Resolved
STBD nav light INOP.
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 29 March 2016
Resolution: New lights installed and tested.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 March 2016
Resolved
Due to seasonal operations, crews were unavailable to conduct drills. Conduct drills proir to 30 Apr 2016.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 4 May 2016
Resolution: Conducted drills with all captains and crews. Cleared CG835.
Fire Fighting › Means of Escape › Blocked
Issued 10 December 2008
Resolved
Hook-and-pile fastened side curtains difficult to remove by one person with minimal force. Propose modification/change to make removal easier prior to operating with curtains in place.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 31 December 2008
Resolution: Corrected
Lifesaving › Hand Flares › Not on Board
Issued 4 June 2008
Resolved
Provide required visual distress signals and watertight container marked appropriately.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 4 June 2008
Resolved
Provide onboard 51 adult and a minimum of 6 child size approved lifejackets. Jackets must be adequately marked and stowed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 16 March 2009
Resolution: Corrected
Lifesaving › Lifebuoys › Not on Board
Issued 4 June 2008
Resolved
Provide onboard one Coast Guard Approved life ring equipped with appropriate line, water light and markings.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Lifesaving › Lifeboat › Carriage Requirement
Issued 4 June 2008
Resolved
Provide arrangement to allow for means of recovery of a helpless person from the water, to the satisfaction of the attending CG Marine Inspector. Vessel is certified as an open boat with doors closed; it is the opinion of this OCMI and MSC that while passengers are onboard and vessel is underway door shall remain closed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 16 March 2009
Resolution: Corrected
Fire Fighting › Fire Bucket › Availability
Issued 4 June 2008
Resolved
Provide 3 fire buckets with lines and markings
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Engineering › Bilge Water Management System › Pump
Issued 4 June 2008
Resolved
Provide a 5 gpm portable bilge pump with sufficient length of pickup tube and discharge line to dewater bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 June 2008
Resolved
Provide on board first aid kit meeting CG approval under 46CFR160.041.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 16 March 2009
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 4 June 2008
Resolved
Documentation must be provided onboard attesting to compliance with appropriate drug and alcohol testing requirements of 46 Code of Federal Regulations Part 16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 4 June 2008
Resolved
Mark vessel name and haling port on stern
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 June 2008
Resolved
Complete emergency drills and required logs entries to the satisfaction of the attending CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 16 March 2009
Resolution: Corrected
Personnel › Certificates/Documents/Licenses › License, Master
Issued 4 June 2008
Resolved
Provide and post Master's license, COI, COD, stability letter, passenger vessel decal and operations manual.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Navigation › Piloting/Steering › Magnetic Compass
Issued 4 June 2008
Resolved
Provide compass on board vessel and prove proper operation unless routed deemed to meet exception within regulation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Navigation › Piloting/Steering › Marine Charts
Issued 4 June 2008
Resolved
Provide navigation charts and publications for the area of operations
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 4 June 2008
Resolved
Provide mooring lines, anchor, and ground tackle appropriate for vessel route.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Communications › Audible Communications › Bell
Issued 4 June 2008
Resolved
Provide VHF-FM Marine radio, with applicable station & operators’ license, installation certificates, and bell and prove proper operation of system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 16 March 2009
Resolution: Less than 1000 feet.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 4 June 2008
Resolved
Provide onboard two portable battery powered lights
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 4 June 2008
Resolved
Correctly mark operating panel for rudder direction of operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 10 December 2008
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 June 2008
Resolved
Install and demonstrate proper operation of fixed fire extinguishing and detection system in accordance with 46 CFR 181.400 with meets the requirements of .410 or .420. Provide documentation attesting to the installations Coast Guard (CG) approval with number with installation requirements (manual) and temperature rating of the fusible link.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 16 March 2009
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 4 June 2008
Resolved
Provide temperature readings of the engine space during normal operations and during the period the EPA unit blows down. The temperature readings must demonstrate the existence of a margin to account for summer time operation. To accomplish this you must; Monitor engine room temperatures through out the operating season and provide reding to the builder and the local OCMI.
Action required: 705 - Other - as specified
Due 30 June 2009
Resolved 11 March 2010
Resolution: Three temp gages installed at the operating station.