HYUNDAI INTEGRAL is a 2008 freight ship. The Coast Guard has recorded 15 inspections since 2008, most recently in August 2022, along with 3 deficiencies and 4 operational controls.

Records from 2008 to 2022. Most recent: inspection, 22 August 2022.

Built
2008
Last inspected
22 August 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9347592 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
960835
Flag
PANAMA
—
Maury page id
psix-960835

Inspections, by type

…with no type recorded7
Years with a record 7 calendar years (2008–2022)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it52581 - Convention (Subpart B), Gross Ton
31157 - Convention (Subpart B), Net Ton
63254 - Dead Weight, Ton
83933 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

22 August 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7540338
19 June 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6711232
25 April 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6129312
26 September 2015 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5729288
29 July 2012 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4394064
29 January 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4233931
20 January 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4228851
23 September 2011 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4152384
21 July 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4089525
1 October 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3336934
29 August 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3312525
27 August 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3311555
3 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3253588
3 July 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3255089
3 July 2008 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3255686

Deficiency record · 3

Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 July 2011 Resolved
Vessel did not have on board appropriate means to test heat detectors in E/R. Vesseh should have correct component spares for testing. F.S.S. 9.2.5.2 (70c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 September 2011
Resolution: Vessel ordered Heat Gun and sucessfully tested heat detector in galley.
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 29 August 2008 Resolved
Both auxiliary blowers failed during port arrival evolution. The vessel crew renewed the bearings in the after blower motor. The forward blower sent ashore for repairs. Unballanced fans caused the bearings to fail in both blower motors with approximately the same amount of operating hours. This is a relativly new vessel and is considered warranty work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2008
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 29 August 2008 Resolved
Renew electric motor cooling fans to auxiliary blowers.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 September 2008
Resolution: Classification survey was submitted attesting to the fix of the electric motor cooling fans to auxiliary blowers.

Ownership record