VELOS AQUARIUS is a 2008 tank ship. The Coast Guard has recorded 15 inspections since 2020, most recently in April 2026, along with 4 deficiencies and 3 operational controls.
Records from 2020 to 2026. Most recent: inspection, 4 April 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it29266 - Convention (Subpart B), Gross Ton 13129 - Convention (Subpart B), Net Ton 49999 - Dead Weight, Ton 56280 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
4 April 2026Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8341912
4 April 2026PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8343679
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2024Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended... the design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCO observed connector to the fuel solenoid valve for the auxiliary boiler had an arrangement in which it was loose and held together with a clamp.
74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 September 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 20 September 2024Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations... established by the company. The technical nature of the deficiencies (no. 01) provide evidence of a failure of the implementation of the ISM Code. An internal audit report must be submitted prior to clearance of this deficiency.
74 SOLAS (20) IX/3.1
ISM Code Part A/10.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2024Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended... the design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. Vessel fitted with temporary arrangement to secure solenoid valve to auxiliary boiler approved by Administration and RO.
74 SOLAS (04) II-1/26
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 October 2024
Resolution: Vessel has completed repairs on aux boiler and submitted documention through survey report.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 August 2020Resolved
The Administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions in respect of electrical installations. Emergency light on cargo deck found with salt and water in fixture.
74 SOLAS(14) II-1/40.2
10 bc
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 August 2020
Resolved 2 August 2020
Resolution: Vessel replaced damage O-ring in light fixture.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National