MAURY USCG vessel records Sign in
← All vessels

SUN RIDER

SUN RIDER is a 2008 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2008, most recently in September 2020, along with 49 deficiencies and 1 casualty investigation in 2014.

Records from 2008 to 2020. Most recent: inspection, 1 September 2020.

Built
2008
Last inspected
1 September 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE6320
961447
Flag
UNITED STATES
368087010
Maury page id
psix-961447

Inspections, by type

…with no type recorded3
Years with a record 10 calendar years (2008–2020)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it44 - Simplified, Gross Ton
35 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDK7706MMSI 368087010 · active · compulsorily equipped · granted 12 April 2019, expires 12 April 2029
WDE6320MMSI 367378730 · expired · compulsorily equipped · granted 30 September 2008, cancelled 27 February 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 18

1 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7047190
6 July 2019 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6738841
10 August 2018 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6507543
7 April 2017 Internal Structural Exam · Hull Examination · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6120326
8 September 2016 Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5997371
8 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5797900
29 September 2015 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5731142
30 October 2014 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5014648
28 October 2014 Type not recorded
No type recorded · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5016735
15 August 2014 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4955255
14 August 2014 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 4972992
12 August 2014 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4952102
26 August 2011 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4129482
5 July 2011 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4068991
15 September 2010 DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3886814
7 March 2010 Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 3697825
3 September 2008 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3317287
10 July 2008 Construction Oversight · Administrative Inspection · Hull Examination · Inclining Experiment · Initial Certification · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3263269

Deficiency record · 49

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 August 2018 Resolved
Found (43) adult lifejackets in good serviceable conditions, Reject (09) adult lifejackets for poor/deteriorated conditions. VSL's stability letter (Nov 2011), approved for (49) passengers and (03) crew. VSL will carry no more than (40)and (03) crew, until additional (09) adult lifejackets provided on board vessel.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 13 August 2018
Resolution: Owner requested to lower max number of passenegrs on COI to (40).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 August 2018 Resolved
Found inoperable remote shut-off valve on STBD fuel tank.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 13 August 2018
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 September 2016 Resolved
All vessel must have navigation lights that are in compliance with Inland Navigation Rules as required by 46 CFR 183.420. Repair inoperable STBD side light and all round mast light.
Due 22 September 2016
Resolved 9 September 2016
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 September 2016 Resolved
All life jackets must be in serviceable conditions as required by 46 CFR 176.808. Replace (05) adult type I lifejackets with deteriorated inner materials. Reduce # of persons carry to 41 persons until additional (05) life jackets are provided.
Due 22 September 2016
Resolved 9 September 2016
Lifesaving › Lifefloat › Approval
Issued 8 January 2016 Resolved
Submit survival craft replacement proposal to MI for review.
Due 26 February 2016
Resolved 9 January 2016
Documentation › Logs/Records › Logbook (official)
Issued 29 September 2015 Resolved
Weekly, monthly & annual inspetion of life saving equipments must be conducted and logged. No log indicating inspection & maintenace were conducted.
Condition: Improper/Lack of Maintenance
Due 13 October 2015
Resolved 1 October 2015
Documentation › Logs/Records › Logbook (official)
Issued 29 September 2015 Resolved
Crew training must be logged in vessel log with date & discretion of the training. No log on board indicating training / drills conducted.
Condition: Improper/Lack of Maintenance
Due 13 October 2015
Resolved 1 October 2015
Operations/Management › Equipment Service/Testing › EPIRB
Issued 29 September 2015 Resolved
EPIRB must be tested and serviced monthly and be logged in vessel log. No log on board indicating monthly test is being conducted.
Condition: Improper/Lack of Maintenance
Due 13 October 2015
Resolved 1 October 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 September 2015 Resolved
All navigation lights must be in operational condition. Stern light was electrically disconnected.
Due 13 October 2015
Resolved 1 October 2015
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 29 September 2015 Resolved
SSB must operates properly. Antenna was not connected to SSB.
Due 13 November 2015
Resolved 1 October 2015
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 September 2015 Resolved
Adult life jacket must be provided for each person carry on board. COI indicated 44 persons, counted only 43 adult lifejackets. Carry no more than 43 persons until additional adult life jacket is provided on board.
Due 13 October 2015
Resolved 1 October 2015
Lifesaving › Hand Flares › Marking
Issued 29 September 2015 Resolved
Container for distress flares must be marked "DISTRESS SIGNAL". No markings on the water tight container.
Due 13 October 2015
Resolved 1 October 2015
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 September 2015 Resolved
FGFE must be tested and operates properly IAW manufacture instruction. System was unable to shut port engine during normal and override mode test.
Due 13 October 2015
Resolved 1 October 2015
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 29 September 2015 Resolved
All propulsion engines instrument must work properly IAW manufacture instruction. Found port engine with inoperable instrumental panel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2015
Resolved 1 October 2015
Fire Fighting › Remote Fuel Shutoff › General
Issued 29 September 2015 Resolved
Remote fuel shut-off valve must be tested and operates properly. Found port & STBD fuel tanks shut-off valve's pull cable disconnected.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2015
Resolved 1 October 2015
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 September 2015 Resolved
A visual and audible alarm for bilge high level alarm must be provided at the operating station. System is missing audible portion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2015
Resolved 1 October 2015
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 29 September 2015 Resolved
Bilge pump must controlled from central control point with a light indicating pump operation. Found pump controller and indicator light at upper control station inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2015
Resolved 1 October 2015
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 September 2015 Resolved
All distribution panel circuits must be marker and identified
Due 13 October 2015
Resolved 1 October 2015
Electrical › Lighting (service) › Lighting Fixture
Issued 29 September 2015 Resolved
All light fixtures must be in proper operating conditions. Found (06) inoperable cabin lights.
Due 13 October 2015
Resolved 1 October 2015
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 30 October 2014 Resolved
Lost of engine lube oil due to damaged fuel pump mounting bolts. Repair port engine IAW with manufacture specs to be attest by the attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2014
Resolution: Repairs completed. Conducted satisfactory sea trail.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 15 August 2014 Resolved
Damaged port propeller due to grounding. 46CFR176.700. Complete repairs and notify MI to attest repairs and proper operation .
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2014
Resolution: Replaced damaged prop with "in kind" prop. MI witnessed satisfactory OPS test.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 August 2014 Resolved
Due for annual servicing. Last service 13JUL13. 46CFR181.420
Due 20 August 2014
Resolved 2 September 2014
Fire Fighting › Fire Bucket › Quantity
Issued 12 August 2014 Resolved
Missing one fire bucket. 46CFR181.610
Due 20 August 2014
Resolved 14 August 2014
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 August 2014 Resolved
Court 37 adult life jackets. Need additional 7 type I to meet COI 44 persons on board. 46CFR180.71
Due 20 August 2014
Resolved 16 October 2014
Operations/Management › Equipment Service/Testing › EPIRB
Issued 12 August 2014 Resolved
No log for EPIRB monthly testing and servicing. 46CFR185.728
Due 20 August 2014
Resolved 14 August 2014
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 12 August 2014 Resolved
No SSB on board, VSL has oceans route on COI. 47CFR80, 46CFR184.502
Due 20 August 2014
Resolved 2 September 2014
Resolution: Owner decided to change vessel route to limited coastwise to avoid having SSB radio on board.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 12 August 2014 Resolved
Missing Navigation rules and Charts. 46CFR184.420
Due 20 August 2014
Resolved 14 August 2014
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 12 August 2014 Resolved
Missing lights on all life jackets, VSL has Oceans route on COI. 46CFR180.75
Due 20 August 2014
Resolved 2 September 2014
Resolution: Owner decided to change vessel route to limited coastwise. No life jacket light require.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 12 August 2014 Resolved
Found wasted hose clamps on port fuel tank fill hose. 46CFR182.445
Due 20 August 2014
Resolved 14 August 2014
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 12 August 2014 Resolved
Inoperable bilge high level alarms for FWD, MID, and AFT spaces. 46CFR182530
Due 20 August 2014
Resolved 14 August 2014
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 August 2014 Resolved
Found 3 - 5 gallon portable diesel tanks stored in steering compartment. 46CFR182.458
Due 20 August 2014
Resolved 14 August 2014
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 August 2014 Resolved
Found inoperable portable lights. 46CFR183.430
Due 20 August 2014
Resolved 2 September 2014
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 August 2014 Resolved
Found first aid kit with incomplete inventory. 46CFR160.041
Due 20 August 2014
Resolved 14 August 2014
Communications › Radio Communications › VHF Radiotelephone
Issued 26 August 2011 Resolved
Found VHF not in a operable status.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2011
Resolution: Conducted operational test on a newly installed VHF, all sat.
Lifesaving › Hand Flares › Quantity
Issued 26 August 2011 Resolved
Missing (04) orange flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2011
Resolution: (04) additional oranges flares provided on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 August 2011 Resolved
Found dead end wires under control counsel.
Due 9 September 2011
Resolved 14 November 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 26 August 2011 Resolved
In-operable red light for override mode.
Due 9 September 2011
Resolved 14 November 2011
Resolution: Indicator for fireboy fixed fire fighting equip is operational.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 August 2011 Resolved
Found separated sewage tank securing straps.
Due 9 September 2011
Resolved 14 November 2011
Lifesaving › Lifebuoys › Serviceable
Issued 26 August 2011 Resolved
Found (01) life ring with separated inner material.
Due 9 September 2011
Resolved 14 November 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 July 2011 Resolved
Change of route from Limited Coastwise to Oceans.
Due 5 July 2011
Resolved 8 July 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 15 September 2010 Resolved
EAP Requirements - 46 CFR 16.401 Discrepancies: Following Items Displayed: EAP, Policy/Statement, Hotline Number, Crewmembers properly trained before assuming safety sensitive position, Supervisor received 1 hour EAP training, Employer has Substance Abuse Professional (SAP) name and contact information
Action required: 705 - Other - as specified
Due 8 October 2010
Resolved 23 June 2011
Resolution: Company corrected deficiencies to the satisfaction of the attending USCG.
Navigation › Piloting/Steering › Marine Charts
Issued 3 September 2008 Resolved
Place on board current copy or corrected copy of charts for areas vessel will be operating in.
Action required: 705 - Other - as specified
Resolved 30 September 2008
Communications › Audible Communications › Bell
Issued 3 September 2008 Resolved
Place a bell onboard.
Action required: 705 - Other - as specified
Resolved 21 October 2008
Documentation › Certificates/Documents › FCC SSL
Issued 3 September 2008 Resolved
Ensure Master of vessel carries the original FCC marine radio operators permit.
Action required: 705 - Other - as specified
Resolved 21 October 2008
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 3 September 2008 Resolved
Provide proof vessel personnel are entered into a drug and alcohol testing program.
Action required: 705 - Other - as specified
Resolved 30 September 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 July 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2008
Resolution: Man overboard, fire and abandon ship drills conducted, verified Master''s license, crew CPR, first aid and consortium cards.
Construction/Loadline › Structures › Superstructure
Issued 10 July 2008 Resolved
Control console, associated equipment, and lifesaving appliances were removed (unbolted/disconnected) to facilitate shipping the vessel to Saipan. All connections must be made to satisfaction of MI
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2008
Resolution: All equipment properly re-installed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 July 2008 Resolved
ALL placards and markings shall be made to satisfaction of MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2008
Resolution: All placards and markings completed properly.
Stability › Incline Test › General
Issued 10 July 2008 Resolved
Test was satisfactorilly conducted but awaiting stability letter to be issued by MSC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2008
Resolution: Vessel placed original copy of stability letter on board.

Casualty record · 1

28 October 2014Routine · role: Involved in a Marine Casualty · activity 5016735
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.