MAURY USCG vessel records
← All vessels

STEEL SLINGER

STEEL SLINGER is a 2008 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in March 2026, along with 28 deficiencies and 1 casualty investigation in 2021.

Records from 2016 to 2026. Most recent: inspection, 24 March 2026.

Built
2008
Last inspected
24 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK9233
961497
Flag
UNITED STATES
Maury page id
psix-961497

Documentation record

Registered dimensions (L × B × D)36.0 ft × 14.0 ft × 6.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWTON BOATS INC · SLIDELL, LA, UNITED STATES · built 2008
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

22 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

24 March 2026 Administrative Inspection · Vessel Attendance · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8330928
12 February 2026 Internal Structural Exam · Vessel Attendance · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8304859
29 August 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8236712
3 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8104349
29 April 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7903565
18 April 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7898275
11 April 2024 Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7893552
20 June 2023 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7712998
20 July 2022 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7511632
27 April 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7439330
3 July 2021 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7247169
10 May 2021 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7193469
8 September 2020 Internal Structural Exam · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7053466
20 April 2020 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6943376
15 July 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6750852
27 June 2018 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6455219
25 June 2018 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6453908
11 December 2017 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6320910
13 November 2017 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6307226
7 December 2016 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6053878
10 November 2016 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6039268
27 July 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5954875

Deficiency record · 28

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2024 Resolved
O/O was not able to provide MIS Report. Employees were enrolled with a consortium but only as individual contractors and not under a Marine Employer as required by 46 CFR Part 16.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2024
Resolved 22 April 2024
Resolution: O/O enrolled as a Marine Employer with APCA Consortium.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 18 April 2024 Resolved
Valid EPIRB FCC Registration was not onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2024
Resolved 22 April 2024
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 April 2024 Resolved
Life float weak link was missing tag.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2024
Resolved 29 April 2024
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 June 2023 Resolved
Windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Witnessed a cracked window on the starboard-side of the Salon. Repair or replace the window by next Drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 June 2023
Resolved 11 April 2024
Resolution: Corrected
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 September 2020 Resolved
Replace expired EPIRB battery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2020
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 8 September 2020 Resolved
Replace expired EPIRB Hydro.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 September 2020 Resolved
Renew life float Painter and float light line.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 September 2020 Resolved
Provide 6 red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 27 June 2018 Resolved
Each window must be capable of with standing maximum load from wind and wave loading conditions. The vessel's port forward window was fractured. Vessel owner is required to replace the port forward window by 11 July 2018
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2018
Resolved 9 July 2018
Resolution: corrected, all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2018 Resolved
The vessel is required to meet the material standards of 46 CFR 176.804 for machinery. The vessel's cutlass bearing was worn. The vessel operator is required to replace the cutlass bearing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2018
Resolved 27 June 2018
Resolution: Corrected; all SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 June 2018 Resolved
The vessel shall meet the the requirements of 46 CFR 179,360 for watertight integrity. The vessel's forward and aft hatches have worn/broken gaskets. The vessel owner is required to replace the gaskets on the forward and aft hatches.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2018
Resolved 27 June 2018
Resolution: Corrected; all SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 June 2018 Resolved
The vessel is required to meet the requirements for watertight bulkheads of 46 CFR 179.320. The vessel's forward engine room bulkhead has several openings that are not water tight. The vessel owner is required to make the forward engine room bulkhead water tight.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2018
Resolved 27 June 2018
Resolution: corrected; all SAT.
Lifesaving › Lifefloat › Paddle
Issued 11 December 2017 Resolved
Replace lifefloat oars, painter line, and waterlight
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2018
Resolved 19 December 2017
Resolution: Vessel replaced oar, line and waterlight
Construction/Loadline › Penetrations › Gasket
Issued 11 December 2017 Resolved
Replace gasket on steering and sewage compartment hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2018
Resolved 19 December 2017
Resolution: Vessel replaced gaskets
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 December 2017 Resolved
Replace ring buoy line
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2018
Resolved 19 December 2017
Resolution: Vessel replaced line
Stability › Water on Deck › General
Issued 11 December 2017 Resolved
Remove water from steering and sewage compartment
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2018
Resolved 19 December 2017
Resolution: Vessel removed water
Engineering › Bilge Water Management System › Interface Detector
Issued 11 December 2017 Resolved
Repair / Replace bilge pump running indicator light
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2018
Resolved 3 January 2018
Resolution: Vessel repaired bilge pump running lights
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 December 2017 Resolved
Provide burn gel
Action required: 705 - Other - as specified
Due 3 January 2018
Resolved 3 January 2018
Resolution: Vessel provided burn gel
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 11 December 2017 Resolved
Provide additional BII fire extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2018
Resolved 19 December 2017
Resolution: Vessel provided extinguisher
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 November 2017 Resolved
Complete a credit annual exam. Vessel annual exam is overdue as of 05Nov17.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 December 2017
Resolved 3 January 2018
Resolution: Vessel completed a credit annual exam
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 7 December 2016 Resolved
Re-stencil the Vessel name and home port on vessel.
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 12 January 2017
Resolution: witnessed
Lifesaving › Lifefloat › Serviceable
Issued 7 December 2016 Resolved
Clean - Repaint- New retro-tape on vessels life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 12 January 2017
Resolution: witnessed
Lifesaving › Lifefloat › Painter
Issued 7 December 2016 Resolved
Replace 100ft Line on painter...
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 12 January 2017
Resolution: witnessed
Communications › Radio Communications › EPIRB
Issued 7 December 2016 Resolved
Have EPRIB registered with NOAA.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 14 December 2016
Resolution: Cleared by email pic..
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 December 2016 Resolved
Provide Alcohol Testing equipment.
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 29 December 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 November 2016 Resolved
Complete credit annual exam
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2016
Resolved 7 December 2016
Resolution: Vessel completed an annual
Construction/Loadline › Penetrations › Valve Flange
Issued 27 July 2016 Resolved
SEA CHEST FITTING WAS NOT CLOSING PROPERLY
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 August 2016
Resolution: ISSUE WAS FIXED
Construction/Loadline › Hull › Strut/Cross Tie
Issued 27 July 2016 Resolved
PROP AND STRUT WERE NOT IN PLACE DURING INSPECTION.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 August 2016
Resolution: THE PROP AND STRUT WERE REPLACED.

Casualty record · 1

3 July 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7247169
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.