← All vessels
CLOVER
CLOVER is a 2007 tank ship. The Coast Guard has recorded 12 inspections since 2008, most recently in June 2019, along with 8 deficiencies and 5 operational controls.
Records from 2008 to 2019. Most recent: inspection, 15 June 2019.
- Built
- 2007
- Last inspected
- 15 June 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9307994 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7OD7
961510
Flag
MARSHALL ISLANDS
—
Maury page id
psix-961510
Inspections, by type
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it56275 - Displacement, Metric Ton
46784 - Dead Weight, Metric Ton
29456 - Convention (Subpart B), Gross Ton
11956 - Convention (Subpart B), Net Ton
46784 - Dead Weight, Metric Ton
29456 - Convention (Subpart B), Gross Ton
11956 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
15 June 2019
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6714466
28 February 2019
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6634431
26 February 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6632292
7 February 2019
ISPS II Exam · Deficiency Check · Ballast Water Examination · COC-CHEM Renew · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6618641
15 April 2016
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5854979
5 October 2015
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5733399
1 October 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5733717
2 August 2011
ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4102181
15 July 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4079100
28 January 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3669406
10 July 2009
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3530396
16 July 2008
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3270260
Deficiency record · 8
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: The vessel failed to fully implement the requirements of the ISM Code through their SMS procedures as evident by the following deficiencies indicating that the ship and/or company are not meeting the SMS requirements. Recommend an external audit. The safety management system shall be maintained in accordance with the provisions of the International Safety Management Code.
The company should establish procedures, plans and instructions including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel.
The company should identify equipment and technical systems the sudden operationsl failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. These measures should include the regular testing of standby arrangements and equipment or technical systems that are not in continuous use. The following deficiencies were noted: 74SOLAS(14)IX/5. ISM Code Part A/7. ISM Code Part A/10.3. 30abc.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - 1) The ship’s Safety Management System requires 3 operational personal gas detectors. Out of 6 detectors on board, 5 were not operational, leaving only one to be utilized by 21 crew members for the first line of defense on a chemical tank ship. The ship’s Safety Management System requires a 12 month supply of calibration gas on board for the personal gas detectors. There was no calibration gas on board for the personal gas detectors. The vessel’s Class Society and Administration were not notified of these non-conformities. 74SOLAS(14)IX/5. ISM Code Part A/10.3. 30abc.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - 2) The inert gas generator requires calibration prior to cargo operations per the ship’s Safety Management System. The vessel’s last calibration was recorded on 18DEC2018. The crew stated that the last calibration was conducted two days ago, this was not logged. Furthermore, the crew displayed unfamiliarity with the process of calibration.
74SOLAS(14)IX/5. ISM Code Part A/10.3. 30abc.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 7 February 2019
Resolved
2550 - 3) The inert gas generator was actively leaking water from the cover plate. This cover plate showed signs of previous temporary repairs or patches. The vessel’s Class Society and Administration were not notified, confirmed by Flag State Surveyor on board the vessel.
74SOLAS(14)IX/5. ISM Code Part A/10.3. 30abc.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Means shall be provided to control leaks of flammable liquids. Per the Shipboard Preventative Maintenance Schedule, all fuel oil pumps on both #2 and #3 ships service generators were overdue for inspection and overhaul. Also, #1 fuel oil pump on the #2 ship’s service generator was actively spraying fuel, creating a fire hazard. #2 fuel oil pump on the #3 ships service generator was actively weeping fuel. 74SOLAS(14)IX/5. ISM Code Part A/10.1. 74SOLAS(04) II-2/4.1.1. 30abc.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. Hydraulic cargo pump system is displaying “Communication Failure” fault. The vessel’s Class Society and Administration were not notified. 74SOLAS(14)IX/5. ISM Code Part A/10.1. 74SOLAS(14)I/11(a). (Downgraded from Code 30 to Code 17 per CVC appeal response of 25 Feb 2020).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. The jacket water seal on cylinder #2 of the main diesel engine is actively leaking jacket water at an approximate rate of one gallon per hour. The vessel’s Class Society and Administration were not notified. 74SOLAS(14)IX/5. ISM Code Part A/10.1. 74SOLAS(14)I/11(a). 30abc.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 7 February 2019
Resolved
1860 - Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapour concentrations, together with a sufficient set of spares. The vessel only has one portable instrument for measuring oxygen and flammable vapour concentrations. 74SOLAS(14)II-2/4.5.7.1. 17ac.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.