Records from 2016 to 2019. Most recent: inspection, 15 June 2019.
Inspection history · 5
15 June 2019
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6714466
28 February 2019
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6634431
26 February 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6632292
7 February 2019
ISPS II Exam · Deficiency Check · Ballast Water Examination · COC-CHEM Renew · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6618641
15 April 2016
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5854979
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: The vessel failed to fully implement the requirements of the ISM Code through their SMS procedures as evident by the following deficiencies indicating that the ship and/or company are not meeting the SMS requirements. Recommend an external audit. The safety management system shall be maintained in accordance with the provisions of the International Safety Management Code.
The company should establish procedures, plans and instructions including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. The various tasks should be defined and assigned to qualified personnel.
The company should identify equipment and technical systems the sudden operationsl failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. These measures should include the regular testing of standby arrangements and equipment or technical systems that are not in continuous use. The following deficiencies were noted: 74SOLAS(14)IX/5. ISM Code Part A/7. ISM Code Part A/10.3. 30abc.
Action required: 30 - Ship detained
Resolved 9 February 2019
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - 1) The ship’s Safety Management System requires 3 operational personal gas detectors. Out of 6 detectors on board, 5 were not operational, leaving only one to be utilized by 21 crew members for the first line of defense on a chemical tank ship. The ship’s Safety Management System requires a 12 month supply of calibration gas on board for the personal gas detectors. There was no calibration gas on board for the personal gas detectors. The vessel’s Class Society and Administration were not notified of these non-conformities. 74SOLAS(14)IX/5. ISM Code Part A/10.3. 30abc.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 February 2019
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - 2) The inert gas generator requires calibration prior to cargo operations per the ship’s Safety Management System. The vessel’s last calibration was recorded on 18DEC2018. The crew stated that the last calibration was conducted two days ago, this was not logged. Furthermore, the crew displayed unfamiliarity with the process of calibration.
74SOLAS(14)IX/5. ISM Code Part A/10.3. 30abc.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 9 February 2019
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 7 February 2019
Resolved
2550 - 3) The inert gas generator was actively leaking water from the cover plate. This cover plate showed signs of previous temporary repairs or patches. The vessel’s Class Society and Administration were not notified, confirmed by Flag State Surveyor on board the vessel.
74SOLAS(14)IX/5. ISM Code Part A/10.3. 30abc.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 February 2019
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Means shall be provided to control leaks of flammable liquids. Per the Shipboard Preventative Maintenance Schedule, all fuel oil pumps on both #2 and #3 ships service generators were overdue for inspection and overhaul. Also, #1 fuel oil pump on the #2 ship’s service generator was actively spraying fuel, creating a fire hazard. #2 fuel oil pump on the #3 ships service generator was actively weeping fuel. 74SOLAS(14)IX/5. ISM Code Part A/10.1. 74SOLAS(04) II-2/4.1.1. 30abc.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 February 2019
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. Hydraulic cargo pump system is displaying “Communication Failure” fault. The vessel’s Class Society and Administration were not notified. 74SOLAS(14)IX/5. ISM Code Part A/10.1. 74SOLAS(14)I/11(a). (Downgraded from Code 30 to Code 17 per CVC appeal response of 25 Feb 2020).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2019
Resolution: Deficiency rectified to the satisfaction of the Coast Guard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 February 2019
Resolved
2550 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea. The jacket water seal on cylinder #2 of the main diesel engine is actively leaking jacket water at an approximate rate of one gallon per hour. The vessel’s Class Society and Administration were not notified. 74SOLAS(14)IX/5. ISM Code Part A/10.1. 74SOLAS(14)I/11(a). 30abc.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 8 February 2019
Resolution: Deficiency rectified to satisfaction of the Coast Guard.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 7 February 2019
Resolved
1860 - Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapour concentrations, together with a sufficient set of spares. The vessel only has one portable instrument for measuring oxygen and flammable vapour concentrations. 74SOLAS(14)II-2/4.5.7.1. 17ac.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2019
Resolved 28 February 2019
Resolution: Received Class report attesting to proper operational equipment.