← All vessels
DD VIGILANT
DD VIGILANT is a 2007 freight ship. The Coast Guard has recorded 6 inspections since 2008, most recently in February 2016, along with 5 deficiencies and 1 operational control.
Records from 2008 to 2016. Most recent: inspection, 16 February 2016.
- Built
- 2007
- Last inspected
- 16 February 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9357432 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EKW
961681
Flag
PANAMA
—
Maury page id
psix-961681
Inspections, by type
…with no type recorded1
Years with a record
3 calendar years (2008–2016)
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it17136 - Convention (Subpart B), Gross Ton
8917 - Convention (Subpart B), Net Ton
33190 - Displacement, Ton
26520 - Dead Weight, Ton
8917 - Convention (Subpart B), Net Ton
33190 - Displacement, Ton
26520 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 6
16 February 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5815683
25 January 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5799193
24 December 2009
Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3654476
31 July 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3285058
3 July 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3249805
2 July 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3249797
Deficiency record · 5
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 January 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment or other items covered by the survey. PSCO observed a hole in the discharge piping between the Oily Water Separator and the three-way valve.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 24 December 2009
Resolved
0960 At least five of the EEBDs throughout the vessel do not have the required ten minutes of air for emergency escape. All EEBDs must meet SOLAS and FSS Code requirements and be serviced prior to departure.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 24 December 2009
Resolved
0715 Heat and smoke detectors not being properly tested. The ship does not have the appropriate testing materials. The crew has been using lighters and welding rods to test the detectors. The ship must acquire the appropriate testing materials and correctly test the heat and smoke detectors prior to departure.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 24 December 2009
Resolved
0900 Two rubber hoses have been installed on the A/C to provide drainage. The hoses run through the deck, into the incinerator room, then through a bulkhead and into a freshwater fill line. Class 'A' fire boundaries are compromised and water tight integrity of the weather deck as well. Clean fresh water is also compromised.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 24 December 2009
Resolved
0900 The service doors leading from the pantries into both the officer's and crew's mess rooms have been removed from the class 'A' fire boundaries. Crew has reinstalled the serving doors.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.