MAURY USCG vessel records
← All vessels

NYK VENUS

NYK VENUS is a 2007 freight ship. The Coast Guard has recorded 13 inspections since 2016, most recently in April 2024, along with 2 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 7 April 2024.

Built
2007
Last inspected
7 April 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 April 2024
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9312793
962971
Flag
PANAMA
Maury page id
psix-962971

Documentation record

Tonnage as PSIX records it138783 - Displacement, Metric Ton
103207 - Dead Weight, Metric Ton
97825 - Convention (Subpart B), Gross Ton
37907 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

7 April 2024 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7890447
17 November 2023 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826306
4 September 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7552916
2 September 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7549493
6 February 2022 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7393728
8 July 2021 Explosive Handling Operation-Commercial
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7254888
7 July 2021 PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7248003
9 March 2021 Explosive Handling Operation-Commercial
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7154460
11 December 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6871773
9 December 2019 Explosive Handling Operation-Commercial
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6871412
22 August 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6791506
13 May 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6683502
26 December 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6060829

Deficiency record · 2

04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 April 2024 Resolved
PSCO observed hydraulic oil leaking from the bottom of the emergency generator upon starting.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2024
Resolved 18 April 2024
Resolution: Received class survey attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 July 2021 Resolved
THE FIXED FIRE DETECTION AND FIRE ALARM SYSTEMS SHALL BE PERIODICALLY TESTED BY MEANS OF EQUIPMENT TO WHICH THE DETECTOR IS DESIGNED TO RESPOND. PSCO OBSERVED HEAT DETECTOR TESTING TOOL WAS INOPERABLE AND COULD NOT TEST IAW MANUFACTURER TESTING PROCEDURES. 74SOLAS(09)II-2/7.3.2 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 February 2022
Resolution: Recieved class report of corrected def. Ordered new testing tool and conducted satisfactory testing.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.