MTM AMAZON is a 2008 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in April 2025, along with 2 deficiencies and 5 operational controls.
Records from 2016 to 2025. Most recent: inspection, 24 April 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19391 - Convention (Subpart B), Gross Ton 9793 - Convention (Subpart B), Net Ton 41573 - Displacement, Ton 33674 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
24 April 2025COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8113216
23 May 2024COC-CHEM & TVE Annual · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7917138
27 June 2023In-Service Inspection
Physical examination · Liquefied Gas Carrier National Center of Expertise · Activity 7724706
14 March 2023COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7639458
The administration shall satisfy itself that the general structural strength of the hull is sufficient for the draught corresponding to the freeboard assigned. PSCO observed a set in on ship's hull below the waterline and between fram number 56/60 on the port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2024
Resolved 25 May 2024
2050(Operations of machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. When operating the No. 1 steering gear pump in non-follow up mode, the rudder will not go to port. 74SOLAS(2014) I/11(a)-17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2018
Resolved 29 December 2018
Resolution: Received, reviewed and accepted class report DNV-GL stating the deficiency was rectified. Non-followup connections renewed and secured. All in good order.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.