Records from 2017 to 2019. Most recent: inspection, 18 December 2019.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 7 December 2019
Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adventure for the service for which they are intended. PSCO noted exhaust boiler had water leaking from water tubes, which travelled thru exhaust casing to turbo charger on MDE. lagging at turber charger is saturated and is dripping water onto turbo charger. 74SOLAS(04)II-1/26
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 10 December 2019
Resolution: Accepted as Condition of Class, requires hydrotesting and NDT by 9Jan2020
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 7 December 2019
Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO noted multiple exhaust leaks throughout engine room including on the exhaust manifold, turbocharger connection, and in engine casing room. 74SOLAS(04)II-1/26
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 December 2019
Resolution: Rectified via Class Report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 7 December 2019
Resolved
The safety managment system shall be maintained and the company should establish procedures to ensure the ships maintained in conformity with relevent rules and provisions and non conformities. Objective evidence indicates there is an SMS failure abord the vessel. BOM manual 4.4.1 requires the master and C/E to report any damage or deficency to company as soon as they are noted. The boiler water leak was not reported to company, exhaust leaks have not been addressed by crew, vessel personnel are not following procedutes for maintence and repair on electrical systems by inaccurately tagging out inoperable AC units in galley and E/R work shop, and inadequate servicing of EEBD'S. 74SOLAS(04)IX/5 ISM 10.1 & 10.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 December 2019
Resolution: Rectified via Class Report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2019
Resolved
The machinery and associated piping shall be of a design and construction adequate for service for which they are intended. the MDE fuel oil booster dump is leading into makeshift containment (1/2 od plastic jug). This containment is full and presents a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Cleared via RO report, gasket replaced and containment removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 December 2019
Resolved
Guard rails shall be fitted around all exposed decks. PSCO noticed stanchions near rescue boat cracked in half during rescue boat drill when crew members moved it.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 December 2019
Resolution: Stanchion repaired by ships crew while PSCO onboard, all sat. Verified by RO.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 7 December 2019
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO noted four open buckets of oil on deck of purifier room from crew conducting maintence on purifiers the precisions day. Creating a fire hazard. 74SOLAS(09)II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: cleared via RO report, buckets cleaned up
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2019
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO noted injector on #2 cyclinder of MDE sprayed oil on cylinder #1 and #2. 74 SOLAS(09)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Cleared via RO report, gasket renewed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 December 2019
Resolved
the maintence plan shall include at least the following fire protection systems and appliances, where installed, fixed fire detections systems. PSCO noted no manual for UV dector above boiler, no tuve on UV element and cannot verify proper installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Cleared via RO report, manual found and installation verified and tested
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 December 2019
Resolved
Electrical instalations shall be such that the safety of the crew and ship from electrical hazards will be ensured. Electrical connection for the emergency fire pump to junction box has exposed wires causing an electrical hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Cleared via RO report, cable installation corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2019
Resolved
The machinery and associated piping shall be of a design and consideration adequate for the service which they and constuction adequate for service for which they are intended. PSCO noted jacket water leak on MDE cylinder #6 at cylinder header. 74SOLAS(04)II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Accepted as condition of class, due 9Jan2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2019
Resolved
The machinery and associated piping shall be of a design and construction adequate for the service for which they are intended. Automatic switch is missing on the #2 lube oil purifiers that empty into the sludge tank. 74SOLAS(04)II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Accepted as Condition of Class, due 9Jan2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 December 2019
Resolved
Electrical insulations shall ensure safety of crew and ship from electrical hazards. SMS Manual 10.5.2 requires warning signs and work permits. When working on electrical equipment PSCO noted electrical equipment AC unit for galley and AC unit for E/R workshop were in the off position and had red electrical tape across them. C/E and electrician stated the units are inoperable and the electrical tape is to ensure that no one turns on equipment. Crew stated there are no lock-out procedures creating a hazard for the crew.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Cleared via RO report, SMS updates required
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 December 2019
Resolved
The condition of the ship shall be maintained. The pressure switch on boiler fuel supply system is held up by bailing wire. 74SOLAS(14)I-II(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Cleared via RO report, installation made permanent
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 December 2019
Resolved
Thermal insulation of boundaries shall have due regard to fire risk of space and adjacent space. PSCO noted insulation forming an "A" boundary is comprised in engine casing room along bulkhead and corner behind "[name withheld]" and "HT Heater Tank."
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Accepted as Condition of Authority, Due 9Jan2020
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 7 December 2019
Resolved
Firefighting systems and appliances shall be kept in good working order. The emergency fire pump was spraying water from the mechanical seal and multiple other leaks were noticed. Standing water and rust were present indicating a long standing deficiency.
Action required: 10 - Deficiency Rectified
Resolved 7 December 2019
Resolution: Mechanical seal replaced while PSCO onboard, conducted operational test post-repairs, all sat. Verified by RO.