NEW ACTIVITY is a 2007 tank ship. The Coast Guard has recorded 10 inspections since 2017, most recently in June 2025, along with 2 deficiencies and 2 operational controls.
Records from 2017 to 2025. Most recent: inspection, 12 June 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it116104 - Displacement, Metric Ton 99997 - Dead Weight, Metric Ton 55898 - Convention (Subpart B), Gross Ton 29810 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
10 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
12 June 2025COC-TVE Annual · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8157452
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 March 2022Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCO OBSERVED EXCESSIVE LEAKAGE OF WATER FROM THE PACKING GLAND ON THE #1 MAIN SEA WATER PUMP.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2022
Resolved 28 March 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 August 2020Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the rules, regulations, and any additional requirements established by the company. (10.1) The company should identify equipment and technical systems. The sudden failure which may result in hazardous situations. The SMS should provide specific measures aimed at promoting the reliability of such systems. These measures should include regular testing of standby arrangements that are not in continuous use. (10.3)
Shipboard management manual page 796 of 851 (column #44) requires to check alarm actions for fix gas detection every quarter. It took crew approximately 1.5 hours to demonstrate an alarm functioning test of fix gas detection sample point from cargo pump room. Crew provided calibration records on SMS form number FLT-D20CG11 (3/4) but it does not include records of testing alarms. (10.1)
Ships SMS does not outline how crew should test foam monitors, pressure was not sufficient from aft foam monitor by port side superstructure. Crew stated only way to test would be with foam being discharged. (10.3) Later in exam, tested port and stbd monitors with satisfactory pressure without foam discharging. Earlier problem may have been from different pipe diameters.
74 SOLAS 14 IX/ 3.1 ISM Code 10.1 and 10.3
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 21 August 2020
Resolution: Reviewed vessel SMS Corrective Action Reports and class report, all sat.