MAURY USCG vessel records
← All vessels

BBC PACIFIC

BBC PACIFIC is a 2007 freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in May 2023, along with 4 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 8 May 2023.

Built
2007
Last inspected
8 May 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 May 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9427081
966366
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-966366

Documentation record

Tonnage as PSIX records it5261 - Convention (Subpart B), Gross Ton
2382 - Convention (Subpart B), Net Ton
6254 - Dead Weight, Ton
3102 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

8 May 2023 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7680751
6 July 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7246794
24 February 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7145347
13 July 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7004934
23 August 2019 Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6788443
6 July 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5926447

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 August 2019 Resolved
07115 - Fire Dampers - Firefighting systems and appliances shall be kept in good working order and readily for immediate use. Fire dampers to main engineering space are not operational. 74 SOLAS 2014 Cons CH II-2 Reg 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2019
Resolution: Vessel completed repairs of components and provided class report attesting to repairs.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 6 July 2016 Resolved
0725 - Fire Fighting - The Purpose of this regulation is to suppress and swiftly extinguish a fire in the space of origin. For this purpose, the following functional requirements shall be met: fire extinguishing appliances shall be readily available. During the engine room examination PSCO found the hyper-mist system supply valves in the closed position. 74SOLAS(09) II-2/10.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 6 July 2016
Resolution: Corrected on Spot
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 July 2016 Resolved
1402 - Operations/Management - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. Excessive fuel oil leakage and accumulation below fuel oil booster station in engine room on booster machinery housing and below de
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 7 July 2016
Resolution: MSU Baton Rouge PSCO attending vessel. Deficiency has been rectified.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2016 Resolved
0950 - Electrical - All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Three temperature regulating electrical control boxes above the lube oil purifiers had open front panels and exposed wiring. Chief Engineer stated that something is wrong with electrical boxes that causes a buildup of excessive heat and the pane
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 7 July 2016
Resolution: MSU Baton Rouge PSCO attended vessel. Deficiency has been rectified.

Ownership record