Records from 2008 to 2025. Most recent: inspection, 4 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
4 December 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8285526
28 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8260891
29 January 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8075263
1 December 2023
COI Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7826566
24 October 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7806981
16 February 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7637581
18 July 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7510049
7 March 2022
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7407434
18 October 2021
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7272746
9 March 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7149381
6 August 2020
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7043174
10 December 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6797506
2 October 2019
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6797514
10 December 2018
Administrative Inspection · COI Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570903
6 February 2018
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6353881
6 October 2017
Administrative Inspection · Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293508
7 February 2017
Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6083530
5 February 2017
Administrative Inspection · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6290103
9 February 2016
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5811227
19 January 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5796956
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 4 December 2025
Resolved
The latches for the vessel's anchor locker have been painted over and are seized preventing access to the anchor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2023
Resolved
Provide 03 additional adult life jackets.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 December 2023
Resolved
Provide 04 additional red hand distress signals.
Action required: 10 - Deficiency Rectified
Resolved 1 December 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 December 2023
Resolved
Provide a visual indicator at the operating station to indicate when the aft automatic submersible bilge pump is operating.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 December 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2021
Resolved
A Type I adult life jacket must be provided for each person on board. 04 Type I adult life jackets had extensive surface cracks form under inspection and were taken out of service. Provide 04 Type I adult life jackets for a total of 17 on board. -Deficiency Rectified on the spot.
Action required: 10 - Deficiency Rectified
Resolved 9 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2021
Resolved
Mark the name of the vessel in clearly legible block capital letters on the 04 new Type I adult life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2021
Resolved
Current life jacket placard is faded and difficult to read. Provide a legible placard containing the instructions for the donning and use of the Type I life jackets carried on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 10 December 2019
Resolved
Vessel Certificate of Documentation on board was expired.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 December 2019
Resolution: vessel rep sent a picture of current COD
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 December 2019
Resolved
Vessels State registration on board was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 17 February 2020
Resolution: new state registration
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 December 2019
Resolved
Vessels FCC Safety Certificate was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 5 March 2020
Resolution: vessel rep found FCC Safety Certificate
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 December 2019
Resolved
07 Adult life jackets are no longer serviceable. Replace life jackets. Passenger count limited to 08.
Action required: 705 - Other - as specified
Resolved 5 March 2020
Resolution: life jackets were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 December 2019
Resolved
Vessel missing 03 hand red flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 18 February 2020
Resolution: new flares on board
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 December 2019
Resolved
Vessel missing sound producing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2020
Resolution: new air horn
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 December 2019
Resolved
Vessel missing up to date Light list and Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 18 February 2020
Resolution: printed off new publications
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 December 2019
Resolved
Vessel missing 01 portable light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2019
Resolved 18 February 2020
Resolution: 1 new portable light on board
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 October 2019
Resolved
Repair soft spot on Port forward hull below the water line, submit repair proposal to include material type (Glass type, weight, and resin). Area must be properly prepped and ground down to good glass prior to carrying out repairs.
Action required: 705 - Other - as specified
Resolved 8 October 2019
Resolution: Area repaired with two layers of glass using west systems expoy resin.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 October 2019
Resolved
Repair/replace attachment device for forward most lower deck hatch to prevent the loss of hatch. Attachment must be with hinges, chains or other material that is suitable strength.
Action required: 705 - Other - as specified
Resolved 8 October 2019
Resolution: Corrected
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 October 2019
Resolved
Repair gasket on main deck hatch for parachute compartment. Hatch must be able to be made watertight.
Action required: 705 - Other - as specified
Resolved 8 October 2019
Resolution: Gasket repaired.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 February 2018
Resolved
Vessel does not have valid COD. Advised vessel they should not carry passengers without a valid COD.
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 5 March 2018
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 February 2018
Resolved
Vessel's Fireboy system was inoperable for testing/automatic shut-down of engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2018
Resolved 7 February 2018
Resolution: Fireboy fully operational
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 February 2018
Resolved
Vessel's automatic bilge pump indicator lights were not functioning.
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 7 February 2018
Resolution: Indicators fixed.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 6 February 2018
Resolved
Starboard fuel tank vent was not properly grounded.
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 7 February 2018
Resolution: Vent grounded
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 February 2018
Resolved
Starboard fuel shutoff valve did not fully close when operated.
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 7 February 2018
Resolution: Valve fully functioning.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 6 February 2018
Resolved
Post oil discharge placard
Action required: 705 - Other - as specified
Due 6 March 2018
Resolved 7 February 2018
Resolution: Posted placard.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 7 February 2017
Resolved
Prove proper operation of audible and visual alarms for Fireboy system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2017
Resolution: Vessel installed new indicator, tested satisfactory
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 7 February 2017
Resolved
Provide first aid kit with all required contents.
Action required: 705 - Other - as specified
Due 21 February 2017
Resolved 21 February 2017
Resolution: Purchased approved first aid kit
Lifesaving › Lifebuoys › Serviceable
Issued 7 February 2017
Resolved
Renew vessel's life ring
Due 7 March 2017
Resolved 21 February 2017
Resolution: Vessel purchased and installed new life ring
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 February 2017
Resolved
Provide FCC Safety Certificate
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Construction/Loadline › Structures › Manhole
Issued 7 February 2017
Resolved
Attach hatch covers to frame or coaming with captive chains or other devices of substantial strength.
Action required: 705 - Other - as specified
Due 7 March 2017
Resolved 21 February 2017
Resolution: Installed wire from frame to hatch cover.
Communications › Radio Communications › EPIRB
Issued 9 February 2016
Resolved
Replace expired Hydrostatic Release on the EPIRB prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 9 February 2016
Resolution: Vessel replaced expired Hydrostatic Release on the EPIRB prior to the completion of the inspection.
Communications › Radio Communications › VHF Radiotelephone
Issued 9 February 2016
Resolved
Program MMSI # into Digital Select Calling VHF radio. FCC.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: Vessel programed MMSI # 367389240 into DSC VHF radio.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 February 2016
Resolved
Install automatic submersible bilge pump visual indicator at the operating station to indicate when each automatic submersible bilge pump is operating.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 4 March 2016
Resolution: Vessel replaced buld in automatic submersible bilge pump visual indicator at operating station.