MAURY USCG vessel records
← All vessels

CMA CGM ALIAGA

CMA CGM ALIAGA is a 2008 freight ship. The Coast Guard has recorded 5 inspections in 2026, along with 2 deficiencies and 1 operational control.

Records in 2026. Most recent: inspection, 3 April 2026.

Built
2008
Last inspected
3 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9323039
9HA5518
968082
Flag
MALTA
Maury page id
psix-968082

Documentation record

Tonnage as PSIX records it46269 - Dead Weight, Ton
61522 - Displacement, Ton
38332 - Convention (Subpart B), Gross Ton
21924 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

3 April 2026 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8341380
2 March 2026 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8318415
1 March 2026 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8318279
16 January 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8297270
12 January 2026 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8294798

Deficiency record · 2

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 March 2026 Resolved
Each separate circuit shall be protected against short circuit and against overload. PSCO observed circuit breaker in emergency generator room on 220V feeder panel labeled "R.P for Heater" had a 60 AMP breaker installed in place where 15 AMP protection was required. SOLAS (04) II-1/ 45.6.1 Code: 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 2 March 2026
Resolution: Vessel was able to install correct breaker, and PSC team was able to verify correction prior to departure.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 March 2026 Resolved
All steering components and the rudder stock shall be of sound and reliable construction. PSCO observed leak from from steering hydraulic system filter on the number 01 tank. SOLAS (04) II-1/ 29.2.1 Code: 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 3 April 2026
Resolution: VSL cleaned up the oil and replaced internal mechanical components to rectify def.

Ownership record