Records from 2008 to 2015. Most recent: inspection, 7 October 2015.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
7 October 2015
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5737709
23 September 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5721066
6 June 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4329751
18 November 2010
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3894093
25 July 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3277939
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 September 2015
Resolved
2540-emergency preparedness-After two attempts, the vessel's crew was not able to effectively conduct an enclosed rescue drill to meet SOLAS and Safety Management System requirements. The current [name withheld] did not understand the requirement of a drill as defined and the new [name withheld] attempted to run the drill, however the crew was unfamiliar with requirements. SOLAS(am) XI-1/4.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2015
Resolved 25 September 2015
Resolution: Received, reviewed and accepted class report and proper documentation from ABS and Master stating the deficiency was rectified. Crew conducted training and sucessfully preformed training in presence of Class representative.Company also made non conformity
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 September 2015
Resolved
2099-Other (SOLAS Operational Def.)-Crew members with enclosed space entry or rescue responsibilities shall participate in an enclosed space entry and rescue drill to be held on board the ship at least once every two months. PSCO observed ship had not conducted the enclosed space drill since July 18, 2015. SOLAS(am) III/19.3.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 September 2015
Resolved 25 September 2015
Resolution: Received, reviewed and accepted class report and proper documentation from ABS and Master stating the deficiency was rectified. Crew conducted drill with class in attendance.
Engineering › Compressed Air System (control) › Valve
Issued 23 September 2015
No resolution recorded
1499-Other (Prop. & Aux. Machinery)-Suitable pressure relief arrangements shall be provided for all systems. PSCO observed the pressure relief valve on Start Air Receiver #2 was missing the manual pressure relief cap. SOLAS (04) II-1/34.1
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 October 2015 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 September 2015
No resolution recorded
0820-Protection machines/parts-All fuel oil purifiers and lube oil purifiers manual brake cover had been removed, exposing rotating machinery parts. SOLAS (04) II-1/26
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 October 2015 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Radar
Issued 23 September 2015
Resolved
1530-Radar-Every ship of 3,000 gross tonnage and upwards shall have a 3 GHz radar. Vessel's master reported that the S-Band radar started working intermittently while inbound in the Mississippi River. No report was made to the Coast Guard as required by SOLAS amended I/11.c. Technician for radar is currently on board. SOLAS (am) V/19.2.7.1
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 September 2015
Resolved 6 October 2015
Resolution: Received, reviewed and accepted class report and proper documentation from technician stating the deficiency was rectified.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 6 June 2012
Resolved
1499-Other (Prop. & Aux. Machinery)- Vessel has not conducted annual static liquid pressure test. Vessel is prohibited from conducting bunkering operations in U.S. waters until bunker line is static liquid pressure tested and written documentation is provided to US Coast Guard in accordance with 33CFR155.820.-33CFR156.170
Action required: 703 - Prior to bunkering operations
Due 6 June 2012
Resolved 7 June 2012
Resolution: Received, reviewed and accepted proper documentation from the Master stating the deficiency was rectified. The Master provide documentation indicating the bunker line was hydrostatically tested on 06Jun2012.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 6 June 2012
Resolved
0199-Other (certificate)-The transfer procedures required by 33 CFR155.720 must contain, either in the order listed in 33 CFR155.750 or by the use of a cross reference list. Master cannot provide transfer procedures in accordance with 33 CFR155.750.-33 CFR155.750
Action required: 703 - Prior to bunkering operations
Due 6 June 2012
Resolved 23 September 2013
Resolution: Vessel submitted transfer procedures in accordance with 33CFR155.