Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
19 - Simplified, Net Ton
24 - Simplified, Gross Ton
Maury page id
psix-969
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
6 June 2024TPO Audit
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7927507
27 September 2023Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7799218
28 December 2022Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7572562
6 December 2021Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7336298
25 November 2020Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7109099
6 October 2020Initial Certification
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7060854
28 February 2018Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6364643
16 January 2013Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4517435
9 August 2012Industry Initiated Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4412027
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 December 2022Resolved
Each exhaust pipe from an internal combustion engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Engine exhaust pipes on aft 01 deck behind pilot house in reach of personnel. Place guard around exposed exhaust pipe that is in reach of personnel.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 28 December 2022
Resolved 25 January 2023
Resolution: Welded protective steel barrier IWO exhaust piping
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 December 2022Resolved
The portable fire pump must be self-priming and power-driven, with a minimum capacity of at least 300 LPM (80 gpm) at a discharge gauge pressure of not less than 414 kPa (60 psi), measured at the pump discharge. Portable fire pump not meeting minimum capacity. Repair as required.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 January 2023
Resolved 25 January 2023
Resolution: Pump rebuilt and demonstrated capacity above minimum requirements.
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR - KEEP CLOSED” or “WATERTIGHT HATCH - KEEP CLOSED”. Forward void deck hatch missing labeling.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 January 2023
Resolved 25 January 2023
Resolution: Hatch stenciled as required.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 December 2022Resolved
Towing vessels 65 feet or less in length may meet the requirements listed in 33 CFR 183.810 or paragraph (a) of this section. Light arrangement for restricted maneuverability utilizing house hold light bulbs. Remove arrangement or repair as required.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 28 January 2023
Resolved 25 January 2023
Resolution: Light arrangement removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 December 2022Resolved
Unless otherwise specified, all lifesaving equipment must be approved by the Commandant under the approval series specified in each section. Spare lifejackets in engine room do not meet the approval series specified in 46 CFR 141.340. Remove spare life jackets from vessel.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 28 December 2022
Resolved 28 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 December 2021Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates.(3 day and 3 night) Vessel only had 4 approved visual distress signals on-board.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 December 2021
Resolution: New flares installed on vessel
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2021Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Shore tie connection missing cap.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 December 2021
Resolution: New cover installed onto shoretie connection.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 December 2021Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Fuel shutoff locations missing directions for operating.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 December 2021
Resolution: Instructions for operation installed by valves.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 December 2021Resolved
Has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: “Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station”; General alarm signage missing in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 December 2021
Resolution: Signage installed by general alarm light.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 6 December 2021Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks that provide strength and support equivalent to fixed rails. Forward deck area missing rails or equivalent protection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 December 2021
Resolution: Railing installed as required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 December 2021Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Engine room battery cables are not of a type that is suitably protected from wet or corrosive environments.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 7 December 2021
Resolution: Vessel representative provided documentation regarding cable specifications. Specifications meet requirements for use on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 October 2020Resolved
Day and night visual distress signals. Hand-held red flare distress signals, approved under approval series 160.021 or 160.121, and hand-held rocket-propelled parachute red flares, approved under approval series 160.036 or 160.136, are acceptable as both day and night signals.
Flares provided to the CG are not approved under these series. Provide required approved day and night visual distress signals for route (3 day and 3 night)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 25 November 2020
Resolution: Recieved photographic evidence of flares
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 20 October 2020Resolved
Means must be provided to ensure that windows immediately forward of the operating station in the pilothouse allow for adequate visibility to ensure safe navigation regardless of weather conditions.
Wheelhouse forward window cracked. Replace with new.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 25 November 2020
Resolution: Recieved objective photographic evidence that bridge window was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2020Resolved
Electrical components that pose an electrical hazard must be in an enclosure.
Three electrical control switches located in the engine room have exposed cable connections. Install covers over cable connections as required.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 25 November 2020
Resolution: Recieved photographic evidence of repair